Test-Retest Reliability and Minimal Detectable Change in Chester Step Test and 1-Minute Sit-to-Stand Test in Long COVID Patients

被引:1
|
作者
Sevillano-Castano, Ana Isabel [1 ,2 ]
Peroy-Badal, Renata [1 ,2 ]
Torres-Castro, Rodrigo [3 ,4 ,5 ]
Canuelo-Marquez, Ana Maria [6 ]
Rozalen-Bustin, Manuel [6 ]
Modrego-Navarro, Angel [2 ]
De Sousa-De Sousa, Luis [2 ]
Ramos-Alvarez, Juan Jose [7 ]
Mate-Munoz, Jose Luis [2 ]
Garcia-Fernandez, Pablo [2 ]
机构
[1] Hosp Univ Infanta Leonor, Madrid 28031, Spain
[2] Univ Complutense Madrid, Fac Nursing Physiotherapy & Podiatry, Dept Radiol Rehabil & Physiotherapy, Madrid 28040, Spain
[3] Univ Chile, Fac Med, Dept Phys Therapy, Santiago 8331150, Chile
[4] Inst Invest Biomed August Pi i Sunyer IDIBAPS, Barcelona 08036, Spain
[5] Int Physiotherapy Res Network PhysioEvidence, Barcelona 08025, Spain
[6] Alfonso X Univ, Fac Hlth Sci, Dept Phys Act & Sports Sci, Madrid 28691, Spain
[7] Univ Complutense Madrid, Sch Sport Med, Dept Radiol Rehabil & Physiotherapy, Madrid 28040, Spain
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 14期
关键词
submaximal exercise testing; COVID-19; exercise capacity; rehabilitation; 6-MINUTE WALK TEST; REFERENCE VALUES; CHANGE SCORES; STRENGTH; VALIDITY; SAMPLE;
D O I
10.3390/app13148464
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The COVID-19 is a multiorgan disease that appeared in December 2019 in the Chinese province of Wuhan. It produces various clinical manifestations, although it mainly affects the respiratory system. Given these potentially detrimental long-term consequences of COVID-19, an appropriate assessment must be carried out to plan early rehabilitation interventions. To assess the persistent symptoms it produces, as well as exercise tolerance for a given exertion, stress testing is a feasible and cost-effective option. Therefore, the objective of this study was to provide test-retest reliability for the Chester Step Test and 1 minute Sit to Stand tests and to establish the minimum detectable change in Long-COVID patients. Method: This observational, descriptive, cross-sectional study was conducted following the STROBE guidelines. A total of 42 patients carried out, twice per partici-pant, the Chester Step and 1-Minute Sit-to-Stand (1min-STST) tests on two different days, with a five-day time lag between the initial measurement and the second measurement. Results: The Test-retest reliability for the Chester Step was excellent within session ICC (95% CI) 0.96 (0.93 to 0.98), being even better for the 1-STST, ICC (95% CI) 0.98 (0.96 to 0.99). Establishing a change of at least 16.96 steps (MDC90) or 20.15 steps (MDC95) and 1.89 stands (MDC90) or 2.71 stands (MDC95), respectively. Conclusions: The Chester Step and 1min-STST tests are reproducible and reliable tools to measure exercise tolerance in long COVID patients. The minimum detectable changes observed in the values recorded by the participants can be very useful for the evaluation of the effectiveness of interventions applied to these patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Test-Retest Reliability and Validity of 1-Minute Sit-to-Stand Test in Patients With Chronic Heart Failure
    Tanriverdi, Aylin
    Kahraman, Buse Ozcan
    Ozpelit, Ebru
    Savci, Sema
    HEART LUNG AND CIRCULATION, 2023, 32 (04): : 518 - 524
  • [2] Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients
    Schwenk, M.
    Gogulla, S.
    Englert, S.
    Czempik, A.
    Hauer, K.
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (11) : 1931 - 1946
  • [3] A multicentre validation of the 1-minute sit-to-stand test in COPD patients
    Crook, Sarah
    Schultz, Konrad
    Lehbert, Nicola
    Busching, Gilbert
    Jelusic, Danijel
    Keusch, Stephan
    Wittmann, Michael
    Schuler, Michael
    Radtke, Thomas
    Turk, Alexander
    Frey, Martin
    Puhan, Milo
    Frei, Anja
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [4] Reliability of the 1-minute sit-to-stand test in chronic obstructive pulmonary disease
    Thu, Hang Nguyen Thi
    Le Khac, Bao
    Poncin, William
    ANNALS OF PHYSICAL AND REHABILITATION MEDICINE, 2024, 67 (07)
  • [5] TEST-RETEST RELIABILITY AND MINIMAL DETECTABLE CHANGE OF THE HEXAGON AGILITY Test
    Beekhuizen, Kristina S.
    Davis, Maurice D.
    Kolber, Morey J.
    Cheng, Ming-Shun S.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2009, 23 (07) : 2167 - 2171
  • [6] Baseline determinants of 1-minute sit-to-stand test performance in COPD patients
    Crook, Sarah
    Frei, Anja
    Yu, Tsung
    Ter Riet, Gerben
    Puhan, Milo
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [7] Test-retest reliability, agreement, and minimal detectable change in the 6-minute walk test in patients with intermittent claudication
    Sandberg, Anna
    Cider, Asa
    Jivegard, Lennart
    Nordanstig, Joakim
    Wittboldt, Susanna
    Back, Maria
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (01) : 197 - 203
  • [8] The test-retest reliability and the minimal detectable change of the Purdue pegboard test in schizophrenia
    Lee, Posen
    Liu, Chin-Hsuan
    Fan, Chia-Wei
    Lu, Chi-Pang
    Lu, Wen-Shian
    Hsieh, Ching-Lin
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2013, 112 (06) : 332 - 337
  • [9] Cardio-pulmonary exercise test and 1-minute sit-to-stand test correlation in patients with sarcoidosis
    Kokkonouzis, Ioannis
    Pantou, Ioanna
    Papadopoulos, Dimitrios
    Tzogkas, Nikolaos
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [10] Reference values for the 1-minute sit-to-stand test for the Argentine population
    Larrateguy, Santiago
    Burgos, Santiago
    Iglesias, Rocio
    Carrizo, Laura
    Cestari, Martin
    Saavedra, Santiago
    Larrateguy, Luis
    Otto-Yanez, Matias
    Mazzucco, Guillermo
    Gimeno-Santos, Elena
    Torres-Castro, Rodrigo
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62