Test-retest reliability and minimal detectable change of repeated sit-to-stand analysis using one body fixed sensor in geriatric patients

被引:56
|
作者
Schwenk, M. [1 ]
Gogulla, S. [1 ]
Englert, S. [2 ]
Czempik, A. [1 ]
Hauer, K. [1 ]
机构
[1] Heidelberg Univ, Dept Geriatr Res, AGAPLESION Bethanien Hosp, Geriatr Ctr, D-6900 Heidelberg, Germany
[2] Heidelberg Univ, Inst Med Biometry & Informat, D-6900 Heidelberg, Germany
关键词
sit-to-stand; body fixed sensor; reliability; minimal detectable change; geriatric patient; geriatric assessment; PHYSICAL PERFORMANCE-MEASURES; LOWER-EXTREMITY FUNCTION; CHANGE SCORES; OLDER-ADULTS; PEOPLE; CHAIR; REPRODUCIBILITY; ACCELEROMETRY; HEMIPARESIS; STRATEGIES;
D O I
10.1088/0967-3334/33/11/1931
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A majority of geriatric patients experience difficulty in performing sit-to-stand (SiSt) transitions. A detailed assessment of SiSt ability is a prerequisite for successful rehabilitation. Body fixed sensors (BFSs) are increasingly used to assess functional performances. As to date there is no system which analyzes clinically relevant phases of SiSt, the aim of this study was to determine the reliability of an automated approach for quantifying durations and angular velocities of trunk flexion and extension during repeated SiSt transitions using one BFS (DynaPort (R) Hybrid). Forty multimorbid geriatric patients aged 84.1 +/- 6.6 years were included. Each patient participated in two test sessions with a 5 min rest period in between. Intra-and interrater reliability was assessed. Intraclass correlation coefficients (ICCs), absolute and relative standard measurement errors (SEMs, SEMs%) and minimal detectable changes (MDCs95, MDCs95%) were calculated. ICCs were good to excellent for all variables in the total sample (0.80-0.94). The intraobserver group (50%) showed a higher number of excellent ICCs (>=.9) compared to the interobserver subgroup (10%). SEM% was low for all variables (6.9-12.7%). MDC95% ranged 19.2-34.4% and more variables <= 30% were found in the intra- (80%) compared to the inter-observer group (60%). Study results demonstrate that the BFS system provides a reliable analysis of SiSt phases in geriatric patients, and is a substantial improvement over the stopwatch approach used in clinical practice today.
引用
收藏
页码:1931 / 1946
页数:16
相关论文
共 50 条
  • [1] Test-Retest Reliability and Minimal Detectable Change in Chester Step Test and 1-Minute Sit-to-Stand Test in Long COVID Patients
    Sevillano-Castano, Ana Isabel
    Peroy-Badal, Renata
    Torres-Castro, Rodrigo
    Canuelo-Marquez, Ana Maria
    Rozalen-Bustin, Manuel
    Modrego-Navarro, Angel
    De Sousa-De Sousa, Luis
    Ramos-Alvarez, Juan Jose
    Mate-Munoz, Jose Luis
    Garcia-Fernandez, Pablo
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (14):
  • [2] Test-retest reliability of sensor-based sit-to-stand measures in young and older adults
    Regterschot, G. Ruben H.
    Zhang, Wei
    Baldus, Heribert
    Stevens, Martin
    Zijlstra, Wiebren
    [J]. GAIT & POSTURE, 2014, 40 (01) : 220 - 224
  • [3] The Test-Retest Reliability and Minimal Detectable Change of the FitLight TrainerTM
    Myers, Lauren R.
    Toonstra, Jenny L.
    Cripps, Andrea E.
    [J]. INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2022, : 84 - 88
  • [4] TEST-RETEST RELIABILITY AND MINIMAL DETECTABLE CHANGE OF THE HEXAGON AGILITY Test
    Beekhuizen, Kristina S.
    Davis, Maurice D.
    Kolber, Morey J.
    Cheng, Ming-Shun S.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2009, 23 (07) : 2167 - 2171
  • [5] TEST-RETEST RELIABILITY OF SIT-TO-STAND PERFORMANCE MEASURES WITH A PENDANT-WORN ACCELEROMETER
    Zhang Wei
    Regterschot, G. Ruben H.
    Zijlstra, Wiebren
    [J]. JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2012, 20 : S180 - S181
  • [6] Test-Retest Reliability and Validity of 1-Minute Sit-to-Stand Test in Patients With Chronic Heart Failure
    Tanriverdi, Aylin
    Kahraman, Buse Ozcan
    Ozpelit, Ebru
    Savci, Sema
    [J]. HEART LUNG AND CIRCULATION, 2023, 32 (04): : 518 - 524
  • [7] The test-retest reliability and the minimal detectable change of the Purdue pegboard test in schizophrenia
    Lee, Posen
    Liu, Chin-Hsuan
    Fan, Chia-Wei
    Lu, Chi-Pang
    Lu, Wen-Shian
    Hsieh, Ching-Lin
    [J]. JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2013, 112 (06) : 332 - 337
  • [8] Test-Retest Reliability and Minimal Detectable Change of the SmartWheel Clinical Protocol
    Lui, Jordon
    MacGillivray, Megan K.
    Sawatzky, Bonita J.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (12): : 2367 - 2372
  • [9] Test-retest Reliability and Minimal Detectable Change in Exercise Oximetry in Claudicants
    Moyo, Therese Tueguem
    Jehannin, Pierre
    Le Pabic, Estelle
    Le Faucheur, Alexis
    Omarjee, Loukman
    Mahe, Guillaume
    [J]. ANNALS OF VASCULAR SURGERY, 2024, 99 : 19 - 25
  • [10] Automated approach for quantifying the repeated sit-to-stand using one body fixed sensor in young and older adults
    Van Lummel, R. C.
    Ainsworth, E.
    Lindemann, U.
    Zijlstra, W.
    Chiari, L.
    Van Campen, P.
    Hausdorff, J. M.
    [J]. GAIT & POSTURE, 2013, 38 (01) : 153 - 156