Test-Retest Reliability and Minimal Detectable Change in Chester Step Test and 1-Minute Sit-to-Stand Test in Long COVID Patients

被引:1
|
作者
Sevillano-Castano, Ana Isabel [1 ,2 ]
Peroy-Badal, Renata [1 ,2 ]
Torres-Castro, Rodrigo [3 ,4 ,5 ]
Canuelo-Marquez, Ana Maria [6 ]
Rozalen-Bustin, Manuel [6 ]
Modrego-Navarro, Angel [2 ]
De Sousa-De Sousa, Luis [2 ]
Ramos-Alvarez, Juan Jose [7 ]
Mate-Munoz, Jose Luis [2 ]
Garcia-Fernandez, Pablo [2 ]
机构
[1] Hosp Univ Infanta Leonor, Madrid 28031, Spain
[2] Univ Complutense Madrid, Fac Nursing Physiotherapy & Podiatry, Dept Radiol Rehabil & Physiotherapy, Madrid 28040, Spain
[3] Univ Chile, Fac Med, Dept Phys Therapy, Santiago 8331150, Chile
[4] Inst Invest Biomed August Pi i Sunyer IDIBAPS, Barcelona 08036, Spain
[5] Int Physiotherapy Res Network PhysioEvidence, Barcelona 08025, Spain
[6] Alfonso X Univ, Fac Hlth Sci, Dept Phys Act & Sports Sci, Madrid 28691, Spain
[7] Univ Complutense Madrid, Sch Sport Med, Dept Radiol Rehabil & Physiotherapy, Madrid 28040, Spain
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 14期
关键词
submaximal exercise testing; COVID-19; exercise capacity; rehabilitation; 6-MINUTE WALK TEST; REFERENCE VALUES; CHANGE SCORES; STRENGTH; VALIDITY; SAMPLE;
D O I
10.3390/app13148464
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The COVID-19 is a multiorgan disease that appeared in December 2019 in the Chinese province of Wuhan. It produces various clinical manifestations, although it mainly affects the respiratory system. Given these potentially detrimental long-term consequences of COVID-19, an appropriate assessment must be carried out to plan early rehabilitation interventions. To assess the persistent symptoms it produces, as well as exercise tolerance for a given exertion, stress testing is a feasible and cost-effective option. Therefore, the objective of this study was to provide test-retest reliability for the Chester Step Test and 1 minute Sit to Stand tests and to establish the minimum detectable change in Long-COVID patients. Method: This observational, descriptive, cross-sectional study was conducted following the STROBE guidelines. A total of 42 patients carried out, twice per partici-pant, the Chester Step and 1-Minute Sit-to-Stand (1min-STST) tests on two different days, with a five-day time lag between the initial measurement and the second measurement. Results: The Test-retest reliability for the Chester Step was excellent within session ICC (95% CI) 0.96 (0.93 to 0.98), being even better for the 1-STST, ICC (95% CI) 0.98 (0.96 to 0.99). Establishing a change of at least 16.96 steps (MDC90) or 20.15 steps (MDC95) and 1.89 stands (MDC90) or 2.71 stands (MDC95), respectively. Conclusions: The Chester Step and 1min-STST tests are reproducible and reliable tools to measure exercise tolerance in long COVID patients. The minimum detectable changes observed in the values recorded by the participants can be very useful for the evaluation of the effectiveness of interventions applied to these patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Role of 1-minute sit-to-stand in the diagnosis of Long COVID
    Faria, N.
    Oliveira, T.
    Pinto, P.
    Almeida, V.
    Fernandes, M. J.
    Carvalho, R.
    Sucena, M.
    Gomes, J.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [22] Examining The Test-retest Reliability Of A Sit To Stand Power Test In Individuals With Cancer
    Anderson, Kenneth Scott
    Brooks, Alexander M.
    Kocuba, Olivia R.
    Jackson, Kylah E.
    Harrington, Shana E.
    Fairman, Ciaran M.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 1087 - 1087
  • [23] Comparison between the 1-minute sit-to-stand test and quadriceps strength in patients with cystic fibrosis
    Hardy, Sophie
    Berardis, Silvia
    Reychler, Gregory
    Gohy, Sophie
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [24] Test-Retest, Interrater Reliability, and Minimal Detectable Change of the Dynamic Exertion Test (EXiT) for Concussion
    Sinnott, Aaron M.
    Eagle, Shawn R.
    Kochick, Victoria
    Collins, Michael W.
    Elbin, R. J.
    Connaboy, Christopher
    Kontos, Anthony P.
    Bricker, Indira R.
    Sparto, Patrick J.
    Flanagan, Shawn D.
    SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2023, 15 (03): : 410 - 421
  • [25] TEST-RETEST RELIABILITY OF SIT-TO-STAND PERFORMANCE MEASURES WITH A PENDANT-WORN ACCELEROMETER
    Zhang Wei
    Regterschot, G. Ruben H.
    Zijlstra, Wiebren
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2012, 20 : S180 - S181
  • [26] TEST-RETEST RELIABILITY OF THE FIVE-REPETITION SIT-TO-STAND TEST: A SYSTEMATIC REVIEW OF THE LITERATURE INVOLVING ADULTS
    Bohannon, Richard W.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (11) : 3205 - 3207
  • [27] Test-Retest Reliability and Minimal Detectable Change Scores for Sit-to-Stand-to-Sit Tests, the Six-Minute Walk Test, the One-Leg Heel-Rise Test, and Handgrip Strength in People Undergoing Hemodialysis
    Segura-Orti, Eva
    Jose Martinez-Olmos, Francisco
    PHYSICAL THERAPY, 2011, 91 (08): : 1244 - 1252
  • [28] The test-retest reliability, concurrent validity, and minimal detectable change of the L test in patients with total hip arthroplasty
    Fatih Özden
    Gökhan Coşkun
    Serkan Bakırhan
    Bulletin of Faculty of Physical Therapy, 2021, 26 (1)
  • [29] 1-Minute Sit-to-Stand Test SYSTEMATIC REVIEW OF PROCEDURES, PERFORMANCE, AND CLINIMETRIC PROPERTIES
    Bohannon, Richard W.
    Crouch, Rebecca
    JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2019, 39 (01) : 2 - 8
  • [30] The 1-minute sit-to-stand test to detect desaturation during 6-minute walk test in interstitial lung disease
    Oishi, Keiji
    Matsunaga, Kazuto
    Asami-Noyama, Maki
    Yamamoto, Tasuku
    Hisamoto, Yukari
    Fujii, Tetsuya
    Harada, Misa
    Suizu, Junki
    Murakawa, Keita
    Chikumoto, Ayumi
    Matsuda, Kazuki
    Kanesada, Haruka
    Kikuchi, Yujiro
    Hamada, Kazuki
    Uehara, Sho
    Suetake, Ryo
    Ohata, Syuichiro
    Murata, Yoriyuki
    Yamaji, Yoshikazu
    Sakamoto, Kenji
    Ito, Kosuke
    Osoreda, Hisayuki
    Edakuni, Nobutaka
    Kakugawa, Tomoyuki
    Hirano, Tsunahiko
    Yano, Masafumi
    NPJ PRIMARY CARE RESPIRATORY MEDICINE, 2022, 32 (01)