Test-retest reliability, agreement, and minimal detectable change in the 6-minute walk test in patients with intermittent claudication

被引:25
|
作者
Sandberg, Anna [1 ,4 ]
Cider, Asa [1 ,5 ]
Jivegard, Lennart [2 ,3 ,4 ]
Nordanstig, Joakim [2 ,4 ]
Wittboldt, Susanna [1 ]
Back, Maria [1 ,4 ]
机构
[1] Sahlgrens Univ Hosp, Dept Occupat Therapy & Physiotherapy, Vita Straket 13, SE-41345 Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Dept Vasc Surg, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Hlth Technol Assessment Ctr Reg Vastra Gotaland, Gothenburg, Sweden
[4] Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Mol & Clin Med, Gothenburg, Sweden
[5] Univ Gothenburg, Sahlgrenska Acad, Dept Hlth & Rehabil Physiotherapy, Inst Neurosci & Physiol, Gothenburg, Sweden
关键词
Peripheral artery disease; Physical fitness; Reproducibility of results; Walking distance; Intermittent claudication; THERAPEUTIC TRIALS; CHANGE SCORES; OLDER-ADULTS; TREADMILL; DISEASE; PEOPLE; GUIDELINES; EXERCISE; DISTANCE;
D O I
10.1016/j.jvs.2019.02.056
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Standardized walk tests are important for objective assessment of walking distance in patients with intermittent claudication (IC). The 6-minute walk test (6MWT) has been suggested to correlate more closely than testing on a treadmill with everyday ambulatory function, but its measurement properties have hardly been studied in IC. The aim of this study was to determine the test-retest reliability, agreement, standard error of measurement (SEM), and minimal detectable change of the 6MWT in patients with IC. Methods: This reliability and agreement study recruited 102 patients with stable IC (mean age, 72 6 +/- 7.4 years; 43 women) from the vascular surgery outpatient clinic at Sahlgrenska University Hospital in Sweden. The patients performed the 6MWT twice, with at least 30 minutes of rest between tests. To determine test-retest reliability, the intraclass correlation coefficient was calculated. Bland-Altman plots were used to measure agreement. Results: The mean walking distance in both test and retest was 397.8 m (standard deviation, 81.2 m; N = 100), and the individual walking distance varied from 175 to 600 m. Excellent test-retest reliability for the 6MWT (intraclass correlation coefficient, 0.95; 95% confidence interval, 0.9-0.97) was observed. The SEM was 16.6 m (95% confidence interval, 14.6-19.3), the SEM percentage was 4.2%, and the minimal detectable change was 46 m. Five observations (5%) were positioned outside the limits of agreement; there was a small proportional bias, and the scatter of values for differences decreased as the average values increased. Conclusions: The excellent test-retest reliability implies that it is sufficient for a patient with IC to perform the 6MWT once, at every test occasion. For the individual, an improvement or deterioration in maximum walking distance of >46 m after an intervention would be required to be 95% confident that the change is significant. Being a simple and clinically useful test, the 6MWT can be widely used to evaluate the effects of different interventions in patients with IC.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 50 条
  • [1] Test-Retest Reliability of the 6-Minute Walk Test in Individuals With Down Syndrome
    Casey, Amanda F.
    Wang, Xu
    Osterling, Kristin
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11): : 2068 - 2074
  • [2] Test-retest reliability of the 2-and 6-minute walk tests in patients with neuromuscular diseases
    Knak, K.
    Andersen, L.
    Witting, N.
    Vissing, J.
    [J]. NEUROMUSCULAR DISORDERS, 2015, 25 : S273 - S273
  • [3] Test-retest reliability, construct validity and determinants of 6-minute walk test performance in adult patients with asthma
    Meys, R.
    Janssen, S. M. J.
    Franssena, F. M. E.
    Vaesa, A. W.
    Stoffels, A. A. F.
    van Hees, H. W. H.
    van den Borstd, B.
    Klijn, P. H.
    Burtin, C.
    van 't Hul, A. J.
    Spruit, M. A.
    [J]. PULMONOLOGY, 2023, 29 (06): : 486 - 494
  • [4] TEST-RETEST RELIABILITY AND MINIMAL DETECTABLE CHANGE OF THE HEXAGON AGILITY Test
    Beekhuizen, Kristina S.
    Davis, Maurice D.
    Kolber, Morey J.
    Cheng, Ming-Shun S.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2009, 23 (07) : 2167 - 2171
  • [5] The Test-Retest Reliability and Minimal Detectable Change of the FitLight TrainerTM
    Myers, Lauren R.
    Toonstra, Jenny L.
    Cripps, Andrea E.
    [J]. INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2022, : 84 - 88
  • [6] Measuring walking speed in COPD: test-retest reliability of the 30-metre walk test and comparison with the 6-minute walk test
    Andersson, Mikael
    Moberg, Linda
    Svantesson, Ulla
    Sundbom, Ann
    Johansson, Henrik
    Emtner, Margareta
    [J]. PRIMARY CARE RESPIRATORY JOURNAL, 2011, 20 (04): : 434 - 440
  • [7] Reliability, validity and minimal detectable change of 2-minute walk test, 6-minute walk test and 10-meter walk test in frail older adults with dementia
    Chan, Wayne L. S.
    Pin, Tamis W.
    [J]. EXPERIMENTAL GERONTOLOGY, 2019, 115 : 9 - 18
  • [8] The test-retest reliability and the minimal detectable change of the Purdue pegboard test in schizophrenia
    Lee, Posen
    Liu, Chin-Hsuan
    Fan, Chia-Wei
    Lu, Chi-Pang
    Lu, Wen-Shian
    Hsieh, Ching-Lin
    [J]. JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2013, 112 (06) : 332 - 337
  • [9] Test-Retest Reliability and Minimum Detectable Change of 2-Minute Walk Test among Individuals with Knee Osteoarthritis
    Chaudhary, Sheffally
    Suhail, Ammar
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (07)
  • [10] Test-Retest Reliability and Minimal Detectable Change of the SmartWheel Clinical Protocol
    Lui, Jordon
    MacGillivray, Megan K.
    Sawatzky, Bonita J.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (12): : 2367 - 2372