Motion Control of Capsule Robot Based on Adaptive Magnetic Levitation Using Electromagnetic Coil

被引:22
|
作者
Song, Li [1 ]
Dai, Yuguo [2 ]
Wang, Luyao [1 ]
Zhang, Wei [1 ]
Ji, Yiming [1 ]
Cao, Yuqing [1 ]
Wei, Junyi [1 ]
Wang, Fengwu [1 ]
Zhong, Jing [3 ]
Yang, Jiapeng [1 ,4 ]
Feng, Lin [1 ,4 ]
机构
[1] Beihang Univ, Sch Mech Engn & Automat, Beijing 100083, Peoples R China
[2] Univ Tokyo, Dept Mech Engn, Tokyo 1138654, Japan
[3] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100083, Peoples R China
[4] Beihang Univ, Beijing Adv Innovat Ctr Biomed Engn, Beijing 100083, Peoples R China
关键词
Capsule endoscopy; magnetic actuation; magnetic levitation; medical robotics; DYNAMIC CONTROL; SYSTEM; MICROROBOT; ENDOSCOPY; DESIGN;
D O I
10.1109/TASE.2022.3201966
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In view of the magnetically actuated capsule robot applications in diagnoses of human stomach disease, the challenges that are associated with degrees-of-freedom (DOF), environmental adaptability, and the size of the entire system must be addressed. In this study, a new electromagnetic coil system that is based on adaptive magnetic levitation is presented; it is mainly composed of an independent orientation control electromagnetic coil and a magnetic levitation control electromagnetic coil. The system is designed to perform motion control of the capsule, including 3-DOF levitating translational motion control, and pitch and yaw motion control in levitation. In this manner, it compensates for the lack of previous magnetic levitation systems that were based on electromagnetic coils for the control of the tilt angle of the capsule. With torque-based actuation control, the tilt angle of the capsule can be controlled continuously with an angle increment of no more than 2 degrees (within 30 degrees) during levitation. The capsule under the magnetic levitation control, which is based on the fuzzy proportional-integral -derivative controller, can maintain the stability of levitation; the error between the actual capsule position and the required position did not exceed 0.1 mm when the capsule was out of water or completely immersed in it. Moreover, the experiment of the capsule levitating from air to water further verifies the adaptability of the system with regard to the environment; this provides a new examination method for capsule endoscopy. Note to Practitioners-This work is caused by the motion manipulation problem of a magnetically driven capsule robot. Most of the existing magnetically driven capsule robots use a rolling or sliding method that fits tightly against the stomach wall, and these forms of motion make it possible to risk missing diagnoses in the examination of gastric diseases, and the maneuverability limits its further application. This paper proposes an adaptive control strategy for a magnetically driven capsule robot based on magnetic levitation motion. It allows the magnetically driven capsule robot to levitate to any position in the stomach for photography and observation without external mechanical support, and this levitation motion is sufficiently stable. In addition, the proposed capsule robot has independent orientation and position control, which has the potential to achieve automated inspection.
引用
收藏
页码:2720 / 2731
页数:12
相关论文
共 50 条
  • [21] Magnetic levitation control including bogie roll motion
    Ha, Chang-Wan
    Kim, Chang-Hyun
    Lim, Jaewon
    Chae, Jubyeong
    Han, Hyung-Suk
    PROCEEDINGS OF THE 2015 7TH IEEE INTERNATIONAL CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS (CIS) AND ROBOTICS, AUTOMATION AND MECHATRONICS (RAM), 2015,
  • [22] Six-axis magnetic levitation and motion control
    Zhang, Zhipeng
    Menq, Chia-Hsiang
    IEEE TRANSACTIONS ON ROBOTICS, 2007, 23 (02) : 196 - 205
  • [23] Basic study on magnetic levitation system using superconducting coil
    Takase, Singo
    Komori, Mochimitsu
    Nemoto, Kaoru
    Asami, Ken-ichi
    Sakai, Nobuo
    MECHANICAL ENGINEERING JOURNAL, 2015, 2 (03):
  • [24] Fuzzy Logic-Based Adaptive Control Scheme for Magnetic Levitation Systems
    Bojan-Dragos, Claudia-Adina
    Precup, Radu-Emil
    Hergane, Stefania
    Teban, Teodor-Adrian
    Petriu, Emil M.
    2017 IEEE 5TH INTERNATIONAL SYMPOSIUM ON ROBOTICS AND INTELLIGENT SENSORS (IRIS), 2017, : 160 - 165
  • [25] Adaptive tracking control of a magnetic levitation system based on class K, function
    Shao, Ke
    EUROPEAN JOURNAL OF CONTROL, 2024, 76
  • [26] Model Reference based Adaptive Sliding Mode Control of Magnetic Levitation System
    Pati, Avadh
    Pal, Vipin Chandra
    Verma, Vijay Kumar
    2017 4TH INTERNATIONAL CONFERENCE ON POWER, CONTROL & EMBEDDED SYSTEMS (ICPCES), 2017,
  • [27] Adaptive robust nonlinear control of a magnetic levitation system
    Yang, ZJ
    Tateishi, M
    AUTOMATICA, 2001, 37 (07) : 1125 - 1131
  • [28] Capsule Vehicle Dynamics Based on Levitation Coil Design Using Equivalent Model of a Sidewall Electrodynamic Suspension System
    Yoon, Ranhee
    Negash, Birhan Abebaw
    You, Wonhee
    Lim, Jungyoul
    Lee, Jinho
    Lee, Changyoung
    Lee, Kwansup
    ENERGIES, 2021, 14 (16)
  • [29] Robust adaptive backstepping control of a magnetic levitation system
    Mizumoto, Ikuro
    Ohishi, Shinya
    Kumon, Makoto
    Iwai, Zenta
    Kozawa, Ryuichi
    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2007, 73 (07): : 2057 - 2063
  • [30] Robust nonlinear adaptive control for the magnetic levitation system
    Satoh, Yasuyuki
    Nakamura, Hisakazu
    Katayama, Hitoshi
    Nishitani, Hirokazu
    2007 MEDITERRANEAN CONFERENCE ON CONTROL & AUTOMATION, VOLS 1-4, 2007, : 1685 - +