Motion Control of Capsule Robot Based on Adaptive Magnetic Levitation Using Electromagnetic Coil

被引:22
|
作者
Song, Li [1 ]
Dai, Yuguo [2 ]
Wang, Luyao [1 ]
Zhang, Wei [1 ]
Ji, Yiming [1 ]
Cao, Yuqing [1 ]
Wei, Junyi [1 ]
Wang, Fengwu [1 ]
Zhong, Jing [3 ]
Yang, Jiapeng [1 ,4 ]
Feng, Lin [1 ,4 ]
机构
[1] Beihang Univ, Sch Mech Engn & Automat, Beijing 100083, Peoples R China
[2] Univ Tokyo, Dept Mech Engn, Tokyo 1138654, Japan
[3] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100083, Peoples R China
[4] Beihang Univ, Beijing Adv Innovat Ctr Biomed Engn, Beijing 100083, Peoples R China
关键词
Capsule endoscopy; magnetic actuation; magnetic levitation; medical robotics; DYNAMIC CONTROL; SYSTEM; MICROROBOT; ENDOSCOPY; DESIGN;
D O I
10.1109/TASE.2022.3201966
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In view of the magnetically actuated capsule robot applications in diagnoses of human stomach disease, the challenges that are associated with degrees-of-freedom (DOF), environmental adaptability, and the size of the entire system must be addressed. In this study, a new electromagnetic coil system that is based on adaptive magnetic levitation is presented; it is mainly composed of an independent orientation control electromagnetic coil and a magnetic levitation control electromagnetic coil. The system is designed to perform motion control of the capsule, including 3-DOF levitating translational motion control, and pitch and yaw motion control in levitation. In this manner, it compensates for the lack of previous magnetic levitation systems that were based on electromagnetic coils for the control of the tilt angle of the capsule. With torque-based actuation control, the tilt angle of the capsule can be controlled continuously with an angle increment of no more than 2 degrees (within 30 degrees) during levitation. The capsule under the magnetic levitation control, which is based on the fuzzy proportional-integral -derivative controller, can maintain the stability of levitation; the error between the actual capsule position and the required position did not exceed 0.1 mm when the capsule was out of water or completely immersed in it. Moreover, the experiment of the capsule levitating from air to water further verifies the adaptability of the system with regard to the environment; this provides a new examination method for capsule endoscopy. Note to Practitioners-This work is caused by the motion manipulation problem of a magnetically driven capsule robot. Most of the existing magnetically driven capsule robots use a rolling or sliding method that fits tightly against the stomach wall, and these forms of motion make it possible to risk missing diagnoses in the examination of gastric diseases, and the maneuverability limits its further application. This paper proposes an adaptive control strategy for a magnetically driven capsule robot based on magnetic levitation motion. It allows the magnetically driven capsule robot to levitate to any position in the stomach for photography and observation without external mechanical support, and this levitation motion is sufficiently stable. In addition, the proposed capsule robot has independent orientation and position control, which has the potential to achieve automated inspection.
引用
收藏
页码:2720 / 2731
页数:12
相关论文
共 50 条
  • [11] Magnetic Levitation Actuation and Motion Control System with Active Levitation Mode Based on Force Imbalance
    Liu, Guancheng
    Lu, Yonghua
    Xu, Jiajun
    Cui, Zhanxiang
    Yang, Haibo
    APPLIED SCIENCES-BASEL, 2023, 13 (02):
  • [12] A Load Adaptive Control Strategy for Electromagnetic Levitation Systems
    Yan, Feng
    Jiang, Qilong
    Xiao, Song
    Liang, Da
    PROCEEDINGS OF THE 2019 14TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2019), 2019, : 1135 - 1140
  • [13] Enhanced Levitation Performance of Magnetic Levitation System Using HTS Racetrack Coil
    Nakamura, Kota
    Sonoda, Shogo
    Suzuki, Ryuma
    Takao, Tomoaki
    Nakamura, Kazuya
    Tsukamoto, Osami
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (05)
  • [14] Diamagnetically-Stabilized Levitation Control of an Intraluminal Magnetic Capsule
    Lam, Michael
    Mintchev, Martin P.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5615 - 5619
  • [15] Diamagnetically-stabilized levitation control of an intraluminal magnetic capsule
    Lam, Michael
    Mintchev, Martin P.
    GASTROENTEROLOGY, 2007, 132 (04) : A170 - A171
  • [16] Adaptive predictive control based on ship magnetic levitation damping device
    Wang, Wei-Ran
    Yan, Jing-Hao
    Yang, Guan-Jun
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2022, 45 (02) : 138 - 149
  • [17] Motion Control of Robot Based on Fuzzy Adaptive PID Algorithm
    Lei Yanmin
    Du Limin
    Feng Zhibin
    2013 3RD INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND NETWORK TECHNOLOGY (ICCSNT), 2013, : 1310 - 1313
  • [18] Dynamics and motion control of a capsule robot with an opposing spring
    Armen Nunuparov
    Felix Becker
    Nikolay Bolotnik
    Igor Zeidis
    Klaus Zimmermann
    Archive of Applied Mechanics, 2019, 89 : 2193 - 2208
  • [19] Dynamics and motion control of a capsule robot with an opposing spring
    Nunuparov, Armen
    Becker, Felix
    Bolotnik, Nikolay
    Zeidis, Igor
    Zimmermann, Klaus
    ARCHIVE OF APPLIED MECHANICS, 2019, 89 (10) : 2193 - 2208
  • [20] Dynamics and Control of Motion of a Capsule Robot with an Opposing Spring
    Bolotnik, Nikolay
    Nunuparov, Armen
    Chashchukhin, Vladislav
    PROCEEDINGS OF 2016 INTERNATIONAL CONFERENCE STABILITY AND OSCILLATIONS OF NONLINEAR CONTROL SYSTEMS (PYATNITSKIY'S CONFERENCE), 2016,