Bayesian Image Reconstruction Using Weighted Laplace Prior for Lung Respiratory Monitoring With Electrical Impedance Tomography

被引:0
|
作者
Wu, Yang [1 ]
Chen, Bai [1 ]
Liu, Kai [1 ]
Huang, Shan [2 ]
Li, Yan
Jia, Jiabin [3 ]
Yao, Jiafeng [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mech & Elect Engn, Nanjing 210016, Peoples R China
[2] Soochow Univ, Dept Pathol, Affiliated Hosp 1, Suzhou, Peoples R China
[3] Univ Edinburgh, Inst Digital Commun, Sch Engn, Agile Tomog Grp, Edinburgh EH9 3JL, Scotland
基金
英国工程与自然科学研究理事会;
关键词
Electrical impedance tomography; Image reconstruction; Conductivity; Bayes methods; Lung; Inverse problems; Imaging; Block sparse Bayesian learning (BSBL); electrical impedance tomography (EIT); inverse problem; lung imaging; weighted Laplace (WL); REGULARIZATION; ALGORITHMS; ACCURATE; TIKHONOV; SIGNALS;
D O I
10.1109/TIM.2022.3220279
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
poor spatial resolution of electrical impedance tomography (EIT) limits its use in medical devices because of its highly nonlinear and ill-posed nature. A novel hierarchical block sparse Bayesian learning (BSBL) method is designed for lung respiratory monitoring with EIT. It is its excellent modeling capability and noise robustness that allows BSBL to adaptively explore and exploit the internal conductivity distribution, e.g., block sparsity and intra-block correlation. First, the K-nearest neighbor (KNN) strategy is employed to automatically group each block based on the clustering property and incorporated to constrain the intra-block correlation matrix based on the spatial distance. Second, a three-layer hierarchical BSBL model using weighted Laplace (WL) prior is considered to enhance the recovery performance. Finally, an efficient bound optimization (BO) method is performed for Bayesian inference, avoiding the tedious parameter adjustment. This leads to improvements in recovery performance, algorithm robustness, and computational efficiency. Moreover, root mean square error (RMSE), image correlation coefficient (ICC), and relative size coverage ratio (RCR) are applied for quantitative comparisons of image quality. Numerical simulations and in vivo lung respiratory experiments showed that the proposed KNN-BSBL-WL method outperforms existing referenced methods in terms of reconstruction accuracy and computational time. On average, KNN-BSBL-WL obtains the RMSE = 0.07 +/- 0.02, ICC = 0.96 +/- 0.01, and RCR = 0.98 +/- 0.05, which are closest to the true values of the recorded snapshots obtained in the experiments. Meanwhile, the average time of KNN-BSBL-WL is 0.16 s, achieving an acceleration ratio close to similar to 3 compared with the referenced KNN-BSBL method. Therefore, the proposed method is an efficient and robust means of imaging reconstruction, which further improves the feasibility of EIT in respiratory clinical applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Image reconstruction using simulated annealing in electrical impedance tomography: a new approach
    Martins, J. S.
    Moura, C. S.
    Vargas, R. M. F.
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2018, 26 (06) : 834 - 854
  • [32] Image reconstruction using voltage-current system in electrical impedance tomography
    Kim, Bong Seok
    Khambampati, Anil Kumar
    Jang, Yeong Jun
    Kim, Kyung Youn
    Kim, Sin
    NUCLEAR ENGINEERING AND DESIGN, 2014, 278 : 134 - 140
  • [33] Optimisation of electrical Impedance tomography image reconstruction error using heuristic algorithms
    Talha A. Khan
    Sai Ho Ling
    Arslan A. Rizvi
    Artificial Intelligence Review, 2023, 56 : 15079 - 15099
  • [34] Image reconstruction using voltage-current system in electrical impedance tomography
    Kim, S. (sinkim@cau.ac.kr), 1600, Elsevier Ltd (278):
  • [35] Monitoring of the lung fluid movement and estimation of lung area using electrical impedance tomography
    Department of Instrumentation Science, Jadavpur University, Kolkata, India
    不详
    Smart Sens. Meas. Instrum., (161-190):
  • [36] Electrical impedance tomography in monitoring experimental lung injury
    I. Frerichs
    G. Hahn
    T. Schröder
    G. Heilige
    Intensive Care Medicine, 1998, 24 : 829 - 836
  • [37] Electrical impedance tomography for lung ventilation monitoring of the dog
    Gloning, Simon
    Pieper, Korbinian
    Zoeliner, Martin
    Meyer-Lindenberg, Andrea
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2017, 45 (01): : 15 - 21
  • [38] The Research Progress of Electrical Impedance Tomography for Lung Monitoring
    Shi, Yan
    Yang, ZhiGuo
    Xie, Fei
    Ren, Shuai
    Xu, ShaoFeng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [39] Monitoring of lung volume in dogs with electrical impedance tomography
    Adler, A
    Shinozuka, N
    Guardo, R
    Berthiaume, Y
    Bates, J
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 776 - 777
  • [40] Electrical impedance tomography in monitoring experimental lung injury
    Frerichs, I
    Hahn, G
    Schroder, T
    Hellige, G
    INTENSIVE CARE MEDICINE, 1998, 24 (08) : 829 - 836