Bayesian Image Reconstruction Using Weighted Laplace Prior for Lung Respiratory Monitoring With Electrical Impedance Tomography

被引:0
|
作者
Wu, Yang [1 ]
Chen, Bai [1 ]
Liu, Kai [1 ]
Huang, Shan [2 ]
Li, Yan
Jia, Jiabin [3 ]
Yao, Jiafeng [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mech & Elect Engn, Nanjing 210016, Peoples R China
[2] Soochow Univ, Dept Pathol, Affiliated Hosp 1, Suzhou, Peoples R China
[3] Univ Edinburgh, Inst Digital Commun, Sch Engn, Agile Tomog Grp, Edinburgh EH9 3JL, Scotland
基金
英国工程与自然科学研究理事会;
关键词
Electrical impedance tomography; Image reconstruction; Conductivity; Bayes methods; Lung; Inverse problems; Imaging; Block sparse Bayesian learning (BSBL); electrical impedance tomography (EIT); inverse problem; lung imaging; weighted Laplace (WL); REGULARIZATION; ALGORITHMS; ACCURATE; TIKHONOV; SIGNALS;
D O I
10.1109/TIM.2022.3220279
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
poor spatial resolution of electrical impedance tomography (EIT) limits its use in medical devices because of its highly nonlinear and ill-posed nature. A novel hierarchical block sparse Bayesian learning (BSBL) method is designed for lung respiratory monitoring with EIT. It is its excellent modeling capability and noise robustness that allows BSBL to adaptively explore and exploit the internal conductivity distribution, e.g., block sparsity and intra-block correlation. First, the K-nearest neighbor (KNN) strategy is employed to automatically group each block based on the clustering property and incorporated to constrain the intra-block correlation matrix based on the spatial distance. Second, a three-layer hierarchical BSBL model using weighted Laplace (WL) prior is considered to enhance the recovery performance. Finally, an efficient bound optimization (BO) method is performed for Bayesian inference, avoiding the tedious parameter adjustment. This leads to improvements in recovery performance, algorithm robustness, and computational efficiency. Moreover, root mean square error (RMSE), image correlation coefficient (ICC), and relative size coverage ratio (RCR) are applied for quantitative comparisons of image quality. Numerical simulations and in vivo lung respiratory experiments showed that the proposed KNN-BSBL-WL method outperforms existing referenced methods in terms of reconstruction accuracy and computational time. On average, KNN-BSBL-WL obtains the RMSE = 0.07 +/- 0.02, ICC = 0.96 +/- 0.01, and RCR = 0.98 +/- 0.05, which are closest to the true values of the recorded snapshots obtained in the experiments. Meanwhile, the average time of KNN-BSBL-WL is 0.16 s, achieving an acceleration ratio close to similar to 3 compared with the referenced KNN-BSBL method. Therefore, the proposed method is an efficient and robust means of imaging reconstruction, which further improves the feasibility of EIT in respiratory clinical applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Image monitoring for an intraperitoneal bleeding model of pigs using electrical impedance tomography
    Shuai Wanjun
    You Fusheng
    Zhang Wei
    Zhang Hongyi
    Fu Feng
    Shi Xuetao
    Liu Ruigang
    Xu Canhua
    Dong Xiuzhen
    Bao Tingyi
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (02) : 217 - 225
  • [42] Image Monitoring for Head Phantom of Intracranial Hemorrhage Using Electrical Impedance Tomography
    Wang, Lei
    Liu, Wen-Bo
    Yu, Xiao
    Xu, Can-Hua
    Dong, Xiu-Zhen
    Gao, Feng
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 1408 - 1411
  • [43] A genetic algorithm approach to image reconstruction in electrical impedance tomography
    Olmi, R
    Bini, M
    Priori, S
    IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2000, 4 (01) : 83 - 88
  • [44] RBF neural network image reconstruction for electrical impedance tomography
    Wang, C
    Lang, R
    Wang, HX
    PROCEEDINGS OF THE 2004 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2004, : 2549 - 2552
  • [45] Constrained image reconstruction for magnetic detection electrical impedance tomography
    Ireland, Rob H.
    Barber, David C.
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2007, 17 (06) : 379 - 382
  • [47] Three-dimensional image reconstruction for electrical impedance tomography
    Kleinermann, F
    Avis, NJ
    Judah, SK
    Barber, DC
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 : A77 - A83
  • [48] TSS-ConvNet for electrical impedance tomography image reconstruction
    Ameen, Ayman A.
    Sack, Achim
    Poeschel, Thorsten
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (04)
  • [49] Nonlinear reconstruction constrained by image properties in electrical impedance tomography
    Blott, BH
    Daniell, GJ
    Meeson, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05): : 1215 - 1224
  • [50] A Conditional Diffusion Model for Electrical Impedance Tomography Image Reconstruction
    Shi, Shuaikai
    Kang, Ruiyuan
    Liatsis, Panos
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74