An analytical form of ring artifact correction for computed tomography based on directional gradient domain optimization

被引:1
|
作者
Wang, Yuang [1 ]
Chen, Zhiqiang [1 ]
Gao, Hewei [1 ]
Deng, Yifan [1 ]
Zhang, Li [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
directional gradient domain optimization; ring artifacts correction; relative total variation; FLAT-FIELD CORRECTION; REMOVAL; SUPPRESSION; MICROTOMOGRAPHY; STRIPES;
D O I
10.1002/mp.16988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundRing artifact is a common problem in Computed Tomography (CT), which can lead to inaccurate diagnoses and treatment plans. It can be caused by various factors such as detector imperfections, anti-scatter grids, or other nonuniform filters placed in the x-ray beam. Physics-based corrections for these x-ray source and detector non-uniformity, in general cannot completely get rid of the ring artifacts. Therefore, there is a need for a robust method that can effectively remove ring artifacts in the image domain while preserving details.PurposeThis study aims to develop an effective method for removing ring artifacts from reconstructed CT images.MethodsThe proposed method starts by converting the reconstructed CT image containing ring artifacts into polar coordinates, thereby transforming these artifacts into stripes. Relative Total Variation is used to extract the image's overall structural information. For the efficient restoration of intricate details, we introduce Directional Gradient Domain Optimization (DGDO) and design objective functions that make use of both the image's gradient and its overall structure. Subsequently, we present an efficient analytical algorithm to minimize these objective functions. The image obtained through DGDO is then transformed back into Cartesian coordinates, finalizing the ring artifact correction process.ResultsThrough a series of synthetic and real-world experiments, we have effectively demonstrated the prowess of our proposed method in the correction of ring artifacts while preserving intricate details in reconstructed CT images. In a direct comparison, our method has exhibited superior visual quality compared to several previous approaches. These results underscore the remarkable potential of our approach for enhancing the overall quality and clinical utility of CT imaging.ConclusionsThe proposed method offers an analytical solution for removing ring artifacts from CT images while preserving details. As ring artifacts are a common problem in CT imaging, this method has high practical value in the medical field. The proposed method can improve image quality and reduce the difficulty of disease diagnosis, thereby contributing to better patient care.
引用
收藏
页码:4121 / 4132
页数:12
相关论文
共 50 条
  • [31] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Dmytro Luzhbin
    Jay Wu
    Journal of Digital Imaging, 2020, 33 : 71 - 82
  • [32] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Luzhbin, Dmytro
    Wu, Jay
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (01) : 71 - 82
  • [33] A New Scattering Artifact Correction Method Based on K-N Formula for Cone-Beam Computed Tomography
    Liu J.
    Xi X.
    Han Y.
    Li L.
    Bu H.
    Yan B.
    2018, Chinese Optical Society (38):
  • [34] A New Scattering Artifact Correction Method Based on K-N Formula for Cone-Beam Computed Tomography
    Liu Jianbang
    Xi Xiaoqi
    Han Yu
    Li Lei
    Bu Haibing
    Yan Bin
    ACTA OPTICA SINICA, 2018, 38 (11)
  • [35] Metal Artifact Reduction Based on Beam Hardening Correction and Statistical Iterative Reconstruction for X-ray Computed Tomography
    Zhang, Yanbo
    Mou, Xuanqin
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [36] Ring artifact removal method with generative adversarial network for the refraction-contrast computed tomography
    Huang, Z.
    Sunaguchi, N.
    Shimao, D.
    Ichihara, S.
    Yuasa, T.
    Ando, M.
    MEDICAL IMAGING 2021: IMAGE PROCESSING, 2021, 11596
  • [37] GRADIENT-BASED SPARSE APPROXIMATION FOR COMPUTED TOMOGRAPHY
    Sakhaee, Elham
    Arreola, Manuel
    Entezari, Alireza
    2015 IEEE 12TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2015, : 1608 - 1611
  • [38] Identification of a unique cause of ring artifact seen in computed tomography trans-axial images
    Jha, Ashish Kumar
    Purandare, Nilendu C.
    Shah, Sneha
    Agrawal, Archi
    Puranik, Ameya D.
    Rangarajan, Venkatesh
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2013, 28 (04): : 232 - 233
  • [39] Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization
    Zhang, Xiaomeng
    Wang, Jing
    Xing, Lei
    MEDICAL PHYSICS, 2011, 38 (02) : 701 - 711
  • [40] Calibration and artifact correction in an angular-domain fluorescence optical projection tomography system
    Torresa, Veronica C.
    Lia, Chengyue
    Zhoua, Wei
    Brankovb, Jovan G.
    Tichauera, Kenneth M.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XIV, 2021, 11633