Model Image-Based Metal Artifact Reduction for Computed Tomography

被引:0
|
作者
Dmytro Luzhbin
Jay Wu
机构
[1] National Yang-Ming University,Department of Biomedical Imaging and Radiological Sciences
来源
关键词
Computed tomography; Metal artifact reduction; Virtual sinogram; Image inpainting;
D O I
暂无
中图分类号
学科分类号
摘要
Metal implants often produce severe artifacts in the reconstructed computed tomography (CT) images, causing information and image detail loss and making the CT images diagnostically unusable. In order to eliminate the metal artifacts and enhance the diagnostic value of the reconstructed CT images, a post-processing metal artifact reduction algorithm, based on a tissue-class model segmented by thresholding and k-means clustering with spatial information, is proposed. The image inpainting technique is incorporated into the algorithm to improve the segmentation accuracy for CT images severely corrupted by metal artifacts. A study of a water phantom and of two sets of clinical CT images was performed to test the algorithm performance. The proposed method effectively eliminates typical metal artifacts, restores the average CT numbers of different tissues to the proper levels, and preserves the edge and contrast information, thus allowing the accurate reconstruction of the tissue attenuation map. The quality of the artifact-corrected CT images allows them to be subsequently used in other clinical applications, such as three-dimensional rendering, dose estimation for radiotherapy, attenuation correction for PET and SPECT, etc. The algorithm does not rely on the use of the raw sinogram and so is not limited by the proprietary format restrictions.
引用
收藏
页码:71 / 82
页数:11
相关论文
共 50 条
  • [1] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Luzhbin, Dmytro
    Wu, Jay
    [J]. JOURNAL OF DIGITAL IMAGING, 2020, 33 (01) : 71 - 82
  • [2] An image-based metal artifact reduction technique utilizing forward projection in computed tomography
    Ichikawa, Katsuhiro
    Kawashima, Hiroki
    Takata, Tadanori
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 402 - 411
  • [3] An Image-Based Reduction of Metal Artifacts in Computed Tomography
    Pua, Rizza
    Wi, Sunhee
    Park, Miran
    Lee, Jung-Ryun
    Cho, Seungryong
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (01) : 131 - 141
  • [4] Image-based Metal Artifact Reduction in X-ray Computed Tomography utilizing Local Anatomical Similarity
    Dong, Xue
    Yang, Xiaofeng
    Rosenfield, Jonathan
    Elder, Eric
    Dhabaan, Anees
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [5] Metal Artifact Reduction by Morphological Image Filtering for Computed Tomography
    Rodriguez-Gallo, Yakdiel
    Orozco-Morales, Ruben
    Perez-Diaz, Marlen
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 219 - 222
  • [6] Image-based metal artifact reduction in CT images
    Serifovic-Trbalic, A.
    Trbalic, A.
    [J]. 2016 39TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2016, : 442 - 446
  • [7] Gradient image smoothing for metal artifact reduction (GISMAR) in computed tomography
    Rodriguez-Gallo, Yakdiel
    Orozco-Morales, Ruben
    Perez-Diaz, Marlen
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):
  • [8] Normalized Metal Artifact Reduction (NMAR) in Computed Tomography
    Meyer, Esther
    Bergner, Frank
    Raupach, Rainer
    Flohr, Thomas
    Kachelriess, Marc
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3251 - +
  • [9] Normalized metal artifact reduction (NMAR) in computed tomography
    Meyer, Esther
    Raupach, Rainer
    Lell, Michael
    Schmidt, Bernhard
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2010, 37 (10) : 5482 - 5493
  • [10] Metal Artifact Reduction in Computed Tomography by Constrained Optimization
    Zhang, Xiaomeng
    Wang, Jing
    Xing, Lei
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622