An analytical form of ring artifact correction for computed tomography based on directional gradient domain optimization

被引:1
|
作者
Wang, Yuang [1 ]
Chen, Zhiqiang [1 ]
Gao, Hewei [1 ]
Deng, Yifan [1 ]
Zhang, Li [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
directional gradient domain optimization; ring artifacts correction; relative total variation; FLAT-FIELD CORRECTION; REMOVAL; SUPPRESSION; MICROTOMOGRAPHY; STRIPES;
D O I
10.1002/mp.16988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundRing artifact is a common problem in Computed Tomography (CT), which can lead to inaccurate diagnoses and treatment plans. It can be caused by various factors such as detector imperfections, anti-scatter grids, or other nonuniform filters placed in the x-ray beam. Physics-based corrections for these x-ray source and detector non-uniformity, in general cannot completely get rid of the ring artifacts. Therefore, there is a need for a robust method that can effectively remove ring artifacts in the image domain while preserving details.PurposeThis study aims to develop an effective method for removing ring artifacts from reconstructed CT images.MethodsThe proposed method starts by converting the reconstructed CT image containing ring artifacts into polar coordinates, thereby transforming these artifacts into stripes. Relative Total Variation is used to extract the image's overall structural information. For the efficient restoration of intricate details, we introduce Directional Gradient Domain Optimization (DGDO) and design objective functions that make use of both the image's gradient and its overall structure. Subsequently, we present an efficient analytical algorithm to minimize these objective functions. The image obtained through DGDO is then transformed back into Cartesian coordinates, finalizing the ring artifact correction process.ResultsThrough a series of synthetic and real-world experiments, we have effectively demonstrated the prowess of our proposed method in the correction of ring artifacts while preserving intricate details in reconstructed CT images. In a direct comparison, our method has exhibited superior visual quality compared to several previous approaches. These results underscore the remarkable potential of our approach for enhancing the overall quality and clinical utility of CT imaging.ConclusionsThe proposed method offers an analytical solution for removing ring artifacts from CT images while preserving details. As ring artifacts are a common problem in CT imaging, this method has high practical value in the medical field. The proposed method can improve image quality and reduce the difficulty of disease diagnosis, thereby contributing to better patient care.
引用
收藏
页码:4121 / 4132
页数:12
相关论文
共 50 条
  • [21] Wavelet domain-based deep residual learning for metal artifact reduction in computed tomography
    Lee, Seungwan
    Kang, Seonghee
    Choi, Youngeun
    Park, Chanrok
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [22] Ring artifact suppression in X-ray computed tomography using a simple, pixel-wise response correction
    Croton, Linda C. P.
    Ruben, Gary
    Morgan, Kaye S.
    Paganin, David M.
    Kitchen, Marcus J.
    OPTICS EXPRESS, 2019, 27 (10) : 14231 - 14245
  • [23] Ring artifact correction in gamma-ray process tomography imaging
    Yenumula, Lakshminarayana
    Acharya, Rajesh V.
    Kumar, Umesh
    Selvam, T. Palani
    Roy, Kallol
    Patankar, V. H.
    Kar, Soumitra
    APPLIED RADIATION AND ISOTOPES, 2017, 124 : 75 - 82
  • [24] An Improved Ring Artifact Removal Approach for Flat-panel Detector Based Computed Tomography Images
    Zeng, Dong
    Ma, Jianhua
    Zhang, Yunwan
    Bian, Zhaoying
    Huang, Jing
    Chen, Wufan
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [25] Cycle Consistent Generative Motion Artifact Correction in Coronary Computed Tomography Angiography
    Saleem, Amal Muhammad
    Jung, Sunghee
    Chang, Hyuk-Jae
    Lee, Soochahn
    APPLIED SCIENCES-BASEL, 2024, 14 (05):
  • [26] Improving the Performance of a Proton Computed Tomography Scanner with An Empirical Artifact Correction Method
    Dickmann, J.
    Sarosiek, C.
    Goetz, S.
    Pankuch, M.
    Coutrakon, G.
    Johnson, R. P.
    Schulte, R. W.
    Parodi, K.
    Landry, G.
    Dedes, G.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [27] MRI-Based Computed Tomography Metal Artifact Correction Method for Improving Proton Range Calculation Accuracy
    Park, Peter C.
    Schreibmann, Eduard
    Roper, Justin
    Elder, Eric
    Crocker, Ian
    Fox, Tim
    Zhu, X. Ronald
    Dong, Lei
    Dhabaan, Anees
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 91 (04): : 849 - 856
  • [28] Deep Learning Based Projection Domain Metal Segmentation for Metal Artifact Reduction in Cone Beam Computed Tomography
    Agrawal, Harshit
    Hietanen, Ari
    Sarkka, Simo
    IEEE ACCESS, 2023, 11 : 100371 - 100382
  • [29] A Practical Computed Tomography Image Ring Artifact Correction Method for Large-Scale Dead Pixels of X-ray Detector
    Yuan, Cuiyun
    Chen, Zijia
    Qi, Hongliang
    Wu, Shuyu
    Li, Bin
    Ma, Jianhui
    Zhou, Linghong
    Xu, Yuan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (05) : 950 - 958
  • [30] Variation-based Ring Artifact Correction in CT Images
    Huo Q.-R.
    Li J.-W.
    Lu Y.
    Qin M.
    Zidonghua Xuebao/Acta Automatica Sinica, 2019, 45 (09): : 1713 - 1726