Ring artifacts often appear in flat-panel detector based CT images due to the malfunction and mis-calibration of detector elements resulting in stripe artifacts in the sinogram data. In this paper, we propose an improved ring artifacts removal (IRAR) approach by combining multi-resolution analysis and weighted moving average filter methods. Specifically, the multi-resolution analysis method can suppress these high-intensity vertical stripes in the sinogram domain and the moving average filter method is effective to deal with the relatively high-intensity vertical stripes. Experimental results on the data acquired from a commercial micro-CT scanner show that the presented approach can achieve significant gains over the existing methods in the ring artifacts removal while preserving spatial resolution.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Ring artifact corrections in flat-panel detector based cone beam CT
    Abu Anas, Emran Mohammad
    Kim, Jaegon
    Lee, Soo Yeol
    Hasan, Md. Kamrul
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [2] Comparison of ring artifact removal methods using flat panel detector based CT images
    Emran M Abu Anas
    Jae G Kim
    Soo Y Lee
    Md K Hasan
    BioMedical Engineering OnLine, 10
  • [3] Comparison of ring artifact removal methods using flat panel detector based CT images
    Abu Anas, Emran M.
    Kim, Jae G.
    Lee, Soo Y.
    Hasan, Md K.
    BIOMEDICAL ENGINEERING ONLINE, 2011, 10
  • [4] Planar cone-beam computed tomography with a flat-panel detector
    Kim, S. H.
    Kim, D. W.
    Youn, H.
    Kim, D.
    Kam, S.
    Jeon, H.
    Kim, H. K.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [5] Dose and image quality of flat-panel detector volume computed tomography for sinus imaging
    Alspaugh, J.
    Christodoulou, E.
    Goodsitt, M.
    Stayman, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2634 - 2634
  • [6] Characterization of a flat-panel amorphous silicon detector for X-ray computed tomography
    Lee, H.-R.
    Ellingson, W.
    Journal of X-Ray Science and Technology, 2001, 9 (01) : 43 - 53
  • [7] Flat-panel Computed Tomography for Quantification of Aortic Atherosclerosis
    Aboshady, Ibrahim
    Cody, Dianna D.
    Elayda, MacArthur A.
    Vela, Deborah
    DuPont, Herbert L.
    Willerson, James T.
    Buja, L. Maximilian
    Gladish, Gregory W.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 97I - 98I
  • [8] Coronary artery imaging with flat-panel computed tomography
    Knollmann, F
    Pfoh, A
    CIRCULATION, 2003, 107 (08) : 1209 - 1209
  • [9] Feasibility and potential value of flat-panel detector-based computed tomography in myelography after spinal surgery
    Kau, Thomas
    Rabitsch, Egon
    Celedin, Stefan
    Jeschofnig, Barbara
    Illiasch, Herbert
    Eicher, Wolfgang
    Uhl, Eberhard
    Honl, Matthias
    Hausegger, Klaus Armin
    JOURNAL OF NEUROSURGERY-SPINE, 2009, 10 (01) : 66 - 72
  • [10] Flat-panel detector-based computed tomography: Accuracy of experimental growth rate assessment in pulmonary nodules
    Marten, K
    Engelke, C
    Grabbe, E
    Rummeny, EJ
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (05): : 752 - 757