Ring artifacts often appear in flat-panel detector based CT images due to the malfunction and mis-calibration of detector elements resulting in stripe artifacts in the sinogram data. In this paper, we propose an improved ring artifacts removal (IRAR) approach by combining multi-resolution analysis and weighted moving average filter methods. Specifically, the multi-resolution analysis method can suppress these high-intensity vertical stripes in the sinogram domain and the moving average filter method is effective to deal with the relatively high-intensity vertical stripes. Experimental results on the data acquired from a commercial micro-CT scanner show that the presented approach can achieve significant gains over the existing methods in the ring artifacts removal while preserving spatial resolution.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Noninvasive Quantification of the Atherosclerotic Aorta Component with Flat-Panel Computed Tomography in Rabbits
    Aboshady, Ibrahim
    Cody, Dianna D.
    Elayda, MacArthur A.
    Vela, Deborah
    DuPont, Herbert L.
    Willerson, James T.
    Buja, L. Maximilian
    Gladish, Gregory W.
    CIRCULATION, 2008, 118 (18) : S777 - S777
  • [32] Imaging of the midpalatal suture in a porcine model: Flat-panel volume computed tomography compared with multislice computed tomography
    Hahn, Wolfram
    Fricke-Zech, Susanne
    Fialka-Fricke, Julia
    Dullin, Christian
    Zapf, Antonia
    Gruber, Rudolf
    Sennhenn-kirchner, Sabine
    Kubein-Meesenburg, Dietmar
    Sadat-Khonsari, Reza
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (03): : 443 - 449
  • [33] Quantitative Monitoring of Atherosclerotic Plaque Development and Characterization by Flat-Panel Computed Tomography
    Aboshady, Ibrahim
    Cody, Dianna D.
    Johnson, Evan M.
    Vela, Deborah
    Khalil, Kamal G.
    Willerson, James T.
    Buja, L. Maximilian
    Gladish, Gregory W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B166 - B166
  • [34] Reproducibility of trabecular structure analysis using flat-panel volume computed tomography
    Arnold C. Cheung
    Miriam A. Bredella
    Ma’moun Al Khalaf
    Michael Grasruck
    Christianne Leidecker
    Rajiv Gupta
    Skeletal Radiology, 2009, 38 : 1003 - 1008
  • [35] Calibration method and photon flux influences tiled flat-panel photon counting detector image uniformity in computed tomography
    Inkinen, S. I.
    Juntunen, M. A. K.
    Kotiaho, A.
    Nieminen, M. T.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (08)
  • [36] A flat-panel detector digital radiography and a storage phosphor computed radiography: Screening for pneumoconioses
    Takashima, Yoshihiro
    Suganuma, Narufumi
    Sakurazawa, Hirofumi
    Itoh, Harumi
    Hirano, Harukazu
    Shida, Hisao
    Kusaka, Yukinori
    JOURNAL OF OCCUPATIONAL HEALTH, 2007, 49 (01) : 39 - 45
  • [37] C-arm-based flat-panel detector cone-beam computed tomography venography in the diagnosis of iliac vein compression syndrome
    Wang Chang-Ming
    Zhang Wei-Liang
    Li Xuan
    中华医学杂志英文版, 2021, 134 (04) : 431 - 438
  • [38] C-arm-based flat-panel detector cone-beam computed tomography venography in the diagnosis of iliac vein compression syndrome
    Wang, Chang-Ming
    Zhang, Wei-Liang
    Li, Xuan
    CHINESE MEDICAL JOURNAL, 2021, 134 (04) : 431 - 438
  • [39] The amorphous selenium based flat-panel detector. Clinical experiences
    Schmidt, EL
    Herbig, W
    RADIOLOGE, 2003, 43 (05): : 374 - 378
  • [40] Development of a selenium-based flat-panel detector for radiography and fluoroscopy
    Yamada, S
    Tsukamoto, A
    Tanaka, M
    Asahina, H
    Nishiki, M
    Suzuki, K
    Uematsu, Y
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 542 - 547