Comparison of ring artifact removal methods using flat panel detector based CT images

被引:27
|
作者
Abu Anas, Emran M. [1 ]
Kim, Jae G. [2 ]
Lee, Soo Y. [2 ]
Hasan, Md K. [1 ,2 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka, Bangladesh
[2] Kyung Hee Univ, Dept Biomed Engn, Kyungki 446701, South Korea
来源
基金
新加坡国家研究基金会;
关键词
MICROTOMOGRAPHY; SUPPRESSION; TOMOGRAPHY; ALGORITHM; WAVELET;
D O I
10.1186/1475-925X-10-72
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Ring artifacts are the concentric rings superimposed on the tomographic images often caused by the defective and insufficient calibrated detector elements as well as by the damaged scintillator crystals of the flat panel detector. It may be also generated by objects attenuating X-rays very differently in different projection direction. Ring artifact reduction techniques so far reported in the literature can be broadly classified into two groups. One category of the approaches is based on the sinogram processing also known as the pre-processing techniques and the other category of techniques perform processing on the 2-D reconstructed images, recognized as the post-processing techniques in the literature. The strength and weakness of these categories of approaches are yet to be explored from a common platform. Method: In this paper, a comparative study of the two categories of ring artifact reduction techniques basically designed for the multi-slice CT instruments is presented from a common platform. For comparison, two representative algorithms from each of the two categories are selected from the published literature. A very recently reported state-of-the-art sinogram domain ring artifact correction method that classifies the ring artifacts according to their strength and then corrects the artifacts using class adaptive correction schemes is also included in this comparative study. The first sinogram domain correction method uses a wavelet based technique to detect the corrupted pixels and then using a simple linear interpolation technique estimates the responses of the bad pixels. The second sinogram based correction method performs all the filtering operations in the transform domain, i.e., in the wavelet and Fourier domain. On the other hand, the two post-processing based correction techniques actually operate on the polar transform domain of the reconstructed CT images. The first method extracts the ring artifact template vector using a homogeneity test and then corrects the CT images by subtracting the artifact template vector from the uncorrected images. The second post-processing based correction technique performs median and mean filtering on the reconstructed images to produce the corrected images. Results: The performances of the comparing algorithms have been tested by using both quantitative and perceptual measures. For quantitative analysis, two different numerical performance indices are chosen. On the other hand, different types of artifact patterns, e. g., single/band ring, artifacts from defective and mis-calibrated detector elements, rings in highly structural object and also in hard object, rings from different flat-panel detectors are analyzed to perceptually investigate the strength and weakness of the five methods. An investigation has been also carried out to compare the efficacy of these algorithms in correcting the volume images from a cone beam CT with the parameters determined from one particular slice. Finally, the capability of each correction technique in retaining the image information (e. g., small object at the iso-center) accurately in the corrected CT image has been also tested. Conclusions: The results show that the performances of the algorithms are limited and none is fully suitable for correcting different types of ring artifacts without introducing processing distortion to the image structure. To achieve the diagnostic quality of the corrected slices a combination of the two approaches (sinogram- and post-processing) can be used. Also the comparing methods are not suitable for correcting the volume images from a cone beam flat-panel detector based CT.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Comparison of ring artifact removal methods using flat panel detector based CT images
    Emran M Abu Anas
    Jae G Kim
    Soo Y Lee
    Md K Hasan
    BioMedical Engineering OnLine, 10
  • [2] Comparison of ring artifact correction methods for flat-detector CT
    Prell, Daniel
    Kyriakou, Yiannis
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (12): : 3881 - 3895
  • [3] An Improved Ring Artifact Removal Approach for Flat-panel Detector Based Computed Tomography Images
    Zeng, Dong
    Ma, Jianhua
    Zhang, Yunwan
    Bian, Zhaoying
    Huang, Jing
    Chen, Wufan
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [4] Ring artifact corrections in flat-panel detector based cone beam CT
    Abu Anas, Emran Mohammad
    Kim, Jaegon
    Lee, Soo Yeol
    Hasan, Md. Kamrul
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [5] Accelerating Ring Artifact Correction for Flat-Detector CT using the CUDA Framework
    Chen, W.
    Prell, D.
    Kyriakou, Y.
    Kalender, W. A.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [6] A variation-based ring artifact correction method with sparse constraint for flat-detector CT
    Yan, Luxin
    Wu, Tao
    Zhong, Sheng
    Zhang, Qiude
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03): : 1278 - 1292
  • [7] Variation-based Ring Artifact Correction in CT Images
    Huo Q.-R.
    Li J.-W.
    Lu Y.
    Qin M.
    Zidonghua Xuebao/Acta Automatica Sinica, 2019, 45 (09): : 1713 - 1726
  • [8] Reduction of ring artifacts in cone beam CT: Artifact detection and correction for flat panel imagers
    Altunbas, M.
    Shaw, C.
    Chen, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 2287 - 2288
  • [9] Ring artifact correction for industrial CT images
    School of Mechanical Engineering and Automation, Beijing University of Aeronautics and Astronautics, Beijing 100083, China
    Beijing Hangkong Hangtian Daxue Xuebao, 2007, 11 (1378-1382):
  • [10] Ring artifact correction for industrial CT images
    Zhang, QH
    Lu, HN
    Yang, M
    Wang, LM
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 6, 2005, : 596 - 599