Comparison of ring artifact removal methods using flat panel detector based CT images

被引:27
|
作者
Abu Anas, Emran M. [1 ]
Kim, Jae G. [2 ]
Lee, Soo Y. [2 ]
Hasan, Md K. [1 ,2 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka, Bangladesh
[2] Kyung Hee Univ, Dept Biomed Engn, Kyungki 446701, South Korea
来源
BIOMEDICAL ENGINEERING ONLINE | 2011年 / 10卷
基金
新加坡国家研究基金会;
关键词
MICROTOMOGRAPHY; SUPPRESSION; TOMOGRAPHY; ALGORITHM; WAVELET;
D O I
10.1186/1475-925X-10-72
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Ring artifacts are the concentric rings superimposed on the tomographic images often caused by the defective and insufficient calibrated detector elements as well as by the damaged scintillator crystals of the flat panel detector. It may be also generated by objects attenuating X-rays very differently in different projection direction. Ring artifact reduction techniques so far reported in the literature can be broadly classified into two groups. One category of the approaches is based on the sinogram processing also known as the pre-processing techniques and the other category of techniques perform processing on the 2-D reconstructed images, recognized as the post-processing techniques in the literature. The strength and weakness of these categories of approaches are yet to be explored from a common platform. Method: In this paper, a comparative study of the two categories of ring artifact reduction techniques basically designed for the multi-slice CT instruments is presented from a common platform. For comparison, two representative algorithms from each of the two categories are selected from the published literature. A very recently reported state-of-the-art sinogram domain ring artifact correction method that classifies the ring artifacts according to their strength and then corrects the artifacts using class adaptive correction schemes is also included in this comparative study. The first sinogram domain correction method uses a wavelet based technique to detect the corrupted pixels and then using a simple linear interpolation technique estimates the responses of the bad pixels. The second sinogram based correction method performs all the filtering operations in the transform domain, i.e., in the wavelet and Fourier domain. On the other hand, the two post-processing based correction techniques actually operate on the polar transform domain of the reconstructed CT images. The first method extracts the ring artifact template vector using a homogeneity test and then corrects the CT images by subtracting the artifact template vector from the uncorrected images. The second post-processing based correction technique performs median and mean filtering on the reconstructed images to produce the corrected images. Results: The performances of the comparing algorithms have been tested by using both quantitative and perceptual measures. For quantitative analysis, two different numerical performance indices are chosen. On the other hand, different types of artifact patterns, e. g., single/band ring, artifacts from defective and mis-calibrated detector elements, rings in highly structural object and also in hard object, rings from different flat-panel detectors are analyzed to perceptually investigate the strength and weakness of the five methods. An investigation has been also carried out to compare the efficacy of these algorithms in correcting the volume images from a cone beam CT with the parameters determined from one particular slice. Finally, the capability of each correction technique in retaining the image information (e. g., small object at the iso-center) accurately in the corrected CT image has been also tested. Conclusions: The results show that the performances of the algorithms are limited and none is fully suitable for correcting different types of ring artifacts without introducing processing distortion to the image structure. To achieve the diagnostic quality of the corrected slices a combination of the two approaches (sinogram- and post-processing) can be used. Also the comparing methods are not suitable for correcting the volume images from a cone beam flat-panel detector based CT.
引用
收藏
页数:25
相关论文
共 50 条
  • [31] Comparison of Gravitational Search Algorithm and Error Back Propagation Algorithm: Applying to CT Ring Artifact Removal Based On Interpolation
    Chao, Z.
    Lee, H.
    Kim, D.
    Kim, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E479 - E479
  • [32] Comparison measurements of DQE for two flat panel detectors:: Fluoroscopic detector vs. cone beam CT detector
    Benitez, Ricardo Betancourt
    Ning, Ruola
    Conover, David
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [33] Quality of Temporal Bone CT Images: A Comparison of Flat Panel Cone Beam CT and Multi-slice CT
    Komori, Masahiro
    Yanagihara, Naoaki
    Hinohira, Yasuyuki
    Kashiba, Keiko
    Miuchi, Shinya
    Kishida, Yoshiomi
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2012, 8 (01): : 57 - 62
  • [34] Hand images: Comparison of a flat panel digital detector to screen-film and computed radiography detectors
    Pauls, H
    Pollack, T
    Friedberg, R
    Gunl, U
    Kogel, A
    Kohler, K
    RADIOLOGY, 2001, 221 : 160 - 160
  • [35] Flat panel detector-based cone-beam volume CT breast imaging: detector evaluation
    Yu, Y
    Conover, D
    Ning, RL
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 711 - 719
  • [36] Development of CT and 3D-CT Using Flat Panel Detector Based Real-Time Digital Radiography System
    Ravindran, V. R.
    Sreelakshmi, C.
    Vibin
    CT 2008: TOMOGRAPHY CONFLUENCE, 2008, 1050 : 23 - 31
  • [37] Motion Artifact on High-Resolution CT Images of Pediatric Patients: Comparison of Volumetric and Axial CT Methods
    Bastos, Maria d'Almeida
    Lee, Edward Y.
    Strauss, Keith J.
    Zurakowski, David
    Tracy, Donald A.
    Boiselle, Phillip M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) : 1414 - 1418
  • [38] Using a flat-panel detector in high resolution cone beam CT for dental imaging
    Baba, R
    Ueda, K
    Okabe, M
    DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) : 285 - 290
  • [39] Flat panel detector based on a shadow mask plasma display panel
    Zhang, Panpan
    Tu, Yan
    Yang, Lanlan
    Tolner, Harm
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2014, 22 (06) : 287 - 295
  • [40] A RTR/DR/3D-CT imaging system based on flat panel detector
    Sun Jingjing
    Yang Min
    Fu Jian
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 4207 - 4210