An analytical form of ring artifact correction for computed tomography based on directional gradient domain optimization

被引:1
|
作者
Wang, Yuang [1 ]
Chen, Zhiqiang [1 ]
Gao, Hewei [1 ]
Deng, Yifan [1 ]
Zhang, Li [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
directional gradient domain optimization; ring artifacts correction; relative total variation; FLAT-FIELD CORRECTION; REMOVAL; SUPPRESSION; MICROTOMOGRAPHY; STRIPES;
D O I
10.1002/mp.16988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundRing artifact is a common problem in Computed Tomography (CT), which can lead to inaccurate diagnoses and treatment plans. It can be caused by various factors such as detector imperfections, anti-scatter grids, or other nonuniform filters placed in the x-ray beam. Physics-based corrections for these x-ray source and detector non-uniformity, in general cannot completely get rid of the ring artifacts. Therefore, there is a need for a robust method that can effectively remove ring artifacts in the image domain while preserving details.PurposeThis study aims to develop an effective method for removing ring artifacts from reconstructed CT images.MethodsThe proposed method starts by converting the reconstructed CT image containing ring artifacts into polar coordinates, thereby transforming these artifacts into stripes. Relative Total Variation is used to extract the image's overall structural information. For the efficient restoration of intricate details, we introduce Directional Gradient Domain Optimization (DGDO) and design objective functions that make use of both the image's gradient and its overall structure. Subsequently, we present an efficient analytical algorithm to minimize these objective functions. The image obtained through DGDO is then transformed back into Cartesian coordinates, finalizing the ring artifact correction process.ResultsThrough a series of synthetic and real-world experiments, we have effectively demonstrated the prowess of our proposed method in the correction of ring artifacts while preserving intricate details in reconstructed CT images. In a direct comparison, our method has exhibited superior visual quality compared to several previous approaches. These results underscore the remarkable potential of our approach for enhancing the overall quality and clinical utility of CT imaging.ConclusionsThe proposed method offers an analytical solution for removing ring artifacts from CT images while preserving details. As ring artifacts are a common problem in CT imaging, this method has high practical value in the medical field. The proposed method can improve image quality and reduce the difficulty of disease diagnosis, thereby contributing to better patient care.
引用
收藏
页码:4121 / 4132
页数:12
相关论文
共 50 条
  • [1] Ring artifact correction for X-ray computed tomography
    Ma, Jiming
    Song, Yan
    Wang, Qunshu
    Song, Guzhou
    Zhang, Jianqi
    Xia, Jingtao
    Han, Changcai
    Duan, Baojun
    Du, Jiye
    Zhou, Ming
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2014, 26 (12):
  • [2] Feature-Sensitive Ring Artifact Correction for Computed Tomography
    Markus Wedekind
    Susana Castillo
    Marcus Magnor
    Journal of Nondestructive Evaluation, 2023, 42
  • [3] Feature-Sensitive Ring Artifact Correction for Computed Tomography
    Wedekind, Markus
    Castillo, Susana
    Magnor, Marcus
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2023, 42 (01)
  • [4] Ring Artifact Correction for Phase-Insensitive Ultrasound Computed Tomography
    Baker, Christian
    Sarno, Daniel
    Eckersley, Robert J.
    Zeqiri, Bajram
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (03) : 513 - 525
  • [5] Ring artifact correction using detector line-ratios in computed tomography
    Kim, Younguk
    Baek, Jongduk
    Hwang, Dosik
    OPTICS EXPRESS, 2014, 22 (11): : 13380 - 13392
  • [6] Prior-based artifact correction (PBAC) in computed tomography
    Heusser, Thorsten
    Brehm, Marcus
    Ritschl, Ludwig
    Sawall, Stefan
    Kachelriess, Marc
    MEDICAL PHYSICS, 2014, 41 (02)
  • [7] An empirical artifact correction for proton computed tomography
    Dickmann, Jannis
    Sarosiek, Christina
    Goetz, Stefanie
    Pankuch, Mark
    Coutrakon, George
    Johnson, Robert P.
    Schulte, Reinhard W.
    Parodi, Katia
    Landry, Guillaume
    Dedes, George
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 57 - 65
  • [8] Sparsity-based method for ring artifact elimination in computed tomography
    Selim, Mona
    Rashed, Essam A.
    Atiea, Mohammed A.
    Kudo, Hiroyuki
    PLOS ONE, 2022, 17 (06):
  • [9] Simulation-based artifact correction (SBAC) for metrological computed tomography
    Maier, Joscha
    Leinweber, Carsten
    Sawall, Stefan
    Stoschus, Henning
    Ballach, Frederic
    Mueller, Tobias
    Hammer, Michael
    Christoph, Ralf
    Kachelriess, Marc
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (06)
  • [10] Nonlinear Deviation CorrecTion for Ring-Artifact Removal With Cone-Beam Computed Tomography
    Guo, Xiaodong
    Wu, Weiwen
    Duan, Xiaojiao
    Yu, Haijun
    Chang, Dingyue
    He, Peng
    Wang, Jue
    Zhou, Rifeng
    Du, Yu
    An, Kang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71