Prior-based artifact correction (PBAC) in computed tomography

被引:31
|
作者
Heusser, Thorsten [1 ]
Brehm, Marcus [1 ]
Ritschl, Ludwig [2 ]
Sawall, Stefan [1 ,3 ]
Kachelriess, Marc [1 ,3 ]
机构
[1] German Canc Res Ctr, D-69120 Heidelberg, Germany
[2] Ziehm Imaging GmbH, D-90451 Nurnberg, Germany
[3] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
metal artifact reduction; truncation artifact reduction; limited angle artifact reduction; prior knowledge; sinogram inpainting; CONE-BEAM CT; FIELD-OF-VIEW; PRINCIPAL COMPONENT ANALYSIS; RADIATION-THERAPY; IMAGE-RECONSTRUCTION; SHADING CORRECTION; PROJECTION DATA; PLANNING CT; REDUCTION; ALGORITHM;
D O I
10.1118/1.4851536
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Image quality in computed tomography (CT) often suffers from artifacts which may reduce the diagnostic value of the image. In many cases, these artifacts result from missing or corrupt regions in the projection data, e.g., in the case of metal, truncation, and limited angle artifacts. The authors propose a generalized correction method for different kinds of artifacts resulting from missing or corrupt data by making use of available prior knowledge to perform data completion. Methods: The proposed prior-based artifact correction (PBAC) method requires prior knowledge in form of a planning CT of the same patient or in form of a CT scan of a different patient showing the same body region. In both cases, the prior image is registered to the patient image using a deformable transformation. The registered prior is forward projected and data completion of the patient projections is performed using smooth sinogram inpainting. The obtained projection data are used to reconstruct the corrected image. Results: The authors investigate metal and truncation artifacts in patient data sets acquired with a clinical CT and limited angle artifacts in an anthropomorphic head phantom data set acquired with a gantry-based flat detector CT device. In all cases, the corrected images obtained by PBAC are nearly artifact-free. Compared to conventional correction methods, PBAC achieves better artifact suppression while preserving the patient-specific anatomy at the same time. Further, the authors show that prominent anatomical details in the prior image seem to have only minor impact on the correction result. Conclusions: The results show that PBAC has the potential to effectively correct for metal, truncation, and limited angle artifacts if adequate prior data are available. Since the proposed method makes use of a generalized algorithm, PBAC may also be applicable to other artifacts resulting from missing or corrupt data. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Anatomical Prior-Based Automatic Segmentation for Cardiac Substructures from Computed Tomography Images
    Wang, Xuefang
    Li, Xinyi
    Du, Ruxu
    Zhong, Yong
    Lu, Yao
    Song, Ting
    BIOENGINEERING-BASEL, 2023, 10 (11):
  • [2] An empirical artifact correction for proton computed tomography
    Dickmann, Jannis
    Sarosiek, Christina
    Goetz, Stefanie
    Pankuch, Mark
    Coutrakon, George
    Johnson, Robert P.
    Schulte, Reinhard W.
    Parodi, Katia
    Landry, Guillaume
    Dedes, George
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 57 - 65
  • [3] Simulation-based artifact correction (SBAC) for metrological computed tomography
    Maier, Joscha
    Leinweber, Carsten
    Sawall, Stefan
    Stoschus, Henning
    Ballach, Frederic
    Mueller, Tobias
    Hammer, Michael
    Christoph, Ralf
    Kachelriess, Marc
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (06)
  • [4] A Prior-interpolation Based Metal Artifact Reduction Algorithm in Computed Tomography
    Li, Ming
    Liu, Zhaobang
    Dong, Yuefang
    Su, Kai
    Luo, Kangxin
    2014 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2014), 2014, : 24 - 28
  • [5] Edge artifact correction for industrial computed tomography images
    Cai, Yufang
    Li, Dan
    Wang, Jue
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2013, 25 (03): : 755 - 761
  • [6] A prior-based metal artifact reduction algorithm for x-ray CT
    Li, Ming
    Zheng, Jian
    Zhang, Tao
    Guan, Yihui
    Xu, Pin
    Sun, Mingshan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (02) : 229 - 241
  • [7] Ring artifact correction for X-ray computed tomography
    Ma, Jiming
    Song, Yan
    Wang, Qunshu
    Song, Guzhou
    Zhang, Jianqi
    Xia, Jingtao
    Han, Changcai
    Duan, Baojun
    Du, Jiye
    Zhou, Ming
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2014, 26 (12):
  • [8] Feature-Sensitive Ring Artifact Correction for Computed Tomography
    Wedekind, Markus
    Castillo, Susana
    Magnor, Marcus
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2023, 42 (01)
  • [9] Feature-Sensitive Ring Artifact Correction for Computed Tomography
    Markus Wedekind
    Susana Castillo
    Marcus Magnor
    Journal of Nondestructive Evaluation, 2023, 42
  • [10] A Normalized Metal Artifact Reduction Method Using an Artifact-Reduced Prior for Dental Computed Tomography
    Park, Chulkyu
    Lee, Dongyeon
    Lim, Younghwan
    Kim, Guna
    Kim, Kyuseok
    Cho, Hyosung
    Seo, Changwoo
    Lim, Hyunwoo
    Lee, Hunwoo
    Park, Soyoung
    Kang, Seokyoon
    Park, Jeongeun
    Jeon, Duhee
    Kim, Woosung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (03) : 298 - 304