Non-invasive mass and temperature quantifications with spectral CT

被引:7
|
作者
Liu, Leening P. [1 ,2 ]
Hwang, Matthew [3 ]
Hung, Matthew [1 ]
Soulen, Michael C. [1 ]
Schaer, Thomas P. [4 ]
Shapira, Nadav [1 ]
Noel, Peter B. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[3] Reed Coll, Dept Phys, Portland, OR USA
[4] Univ Penn, Sch Vet Med, Dept Clin Studies, Philadelphia, PA USA
关键词
DUAL-ENERGY CT; THERMAL ABLATION THERAPY; COMPUTED-TOMOGRAPHY; MICROWAVE ABLATION; HEPATOCELLULAR-CARCINOMA; ATOMIC-NUMBER; LIVER-LESIONS; DENSITY; THERMOMETRY; FEASIBILITY;
D O I
10.1038/s41598-023-33264-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Spectral CT has been increasingly implemented clinically for its better characterization and quantification of materials through its multi-energy results. It also facilitates calculation of physical density, allowing for non-invasive mass measurements and temperature evaluations by manipulating the definition of physical density and thermal volumetric expansion, respectively. To develop spectral physical density quantifications, original and parametrized Alvarez-Macovski model and electron density-physical density model were validated with a phantom. The best physical density model was then implemented on clinical spectral CT scans of ex vivo bovine muscle to determine the accuracy and effect of acquisition parameters on mass measurements. In addition, the relationship between physical density and changes in temperature was evaluated by scanning and subjecting the tissue to a range of temperatures. The parametrized Alvarez-Macovski model performed best in both model development and validation with errors within +/- 0.02 g/mL. No effect from acquisition parameters was observed in mass measurements, which demonstrated accuracy with a maximum percent error of 0.34%. Furthermore, physical density was strongly correlated (R of 0.9781) to temperature changes through thermal volumetric expansion. Accurate and precise spectral physical density quantifications enable non-invasive mass measurements for pathological detection and temperature evaluation for thermal therapy monitoring in interventional oncology.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Non-invasive and invasive diagnoses of aspergillosis in a rat model by mass spectrometry
    Dominika Luptáková
    Tomáš Pluháček
    Miloš Petřík
    Jiří Novák
    Andrea Palyzová
    Lucie Sokolová
    Anton Škríba
    Blanka Šedivá
    Karel Lemr
    Vladimír Havlíček
    Scientific Reports, 7
  • [22] Non-invasive medical diagnosis of aspergillosis by mass spectrometry
    Havlicek, V.
    MYCOSES, 2017, 60 : 41 - 41
  • [23] CONSTRUCTAL DESIGN OF A NON-INVASIVE TEMPERATURE BASED MASS FLOW RATE SENSOR FOR ALGAE PHOTOBIOREACTORS
    Ribeiro, K.
    Ordonez, J. C.
    Vargas, J. V. C.
    Mariano, A. B.
    CONSTRUCTAL LAW & SECOND LAW CONFERENCE (CLC2017), 2017, : 548 - 567
  • [24] CONSTRUCTAL DESIGN OF A NON-INVASIVE TEMPERATURE BASED MASS FLOW RATE SENSOR FOR ALGAE PHOTOBIOREACTORS
    Ribeiro, Kassiana
    Ordonez, Juan C.
    Vargas, Jose V. C.
    Mariano, Andre B.
    PROCEEDINGS OF THE ROMANIAN ACADEMY SERIES A-MATHEMATICS PHYSICS TECHNICAL SCIENCES INFORMATION SCIENCE, 2018, 19 : 279 - 284
  • [25] Band selection in spectral imaging for non-invasive melanoma diagnosis
    Quinzan, Ianisse
    Sotoca, Jose M.
    Latorre-Carmona, Pedro
    Pla, Filiberto
    Garcia-Sevilla, Pedro
    Boldo, Enrique
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (04): : 514 - 519
  • [26] Spectral Estimation of Chlorophyll for Non-Invasive Assessment in Apple Orchards
    Szabo, Andrea
    Tamas, Janos
    Nagy, Attila
    HORTICULTURAE, 2024, 10 (12)
  • [27] Non-Invasive Measure of Stenosis Severity Through Spectral Analysis
    Byers, Clayton P.
    Sinson, Alexandra M.
    Scheffers, Colette M.
    Ning, Taikang
    PROCEEDINGS OF 2020 IEEE 15TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP 2020), 2020, : 545 - 549
  • [28] NON-INVASIVE
    SPODICK, DH
    ANNALS OF INTERNAL MEDICINE, 1983, 99 (04) : 569 - 569
  • [29] NON-INVASIVE TEMPERATURE MAPPING BY COMPUTERIZED-TOMOGRAPHY
    ZAMENHOF, RG
    STERNICK, ES
    CURRAN, BM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (09): : 1235 - 1235
  • [30] NON-INVASIVE DETERMINATION OF CORE TEMPERATURE DURING ANESTHESIA
    LEES, DE
    KIM, YD
    MACNAMARA, TE
    SOUTHERN MEDICAL JOURNAL, 1980, 73 (10) : 1322 - 1324