Non-invasive mass and temperature quantifications with spectral CT

被引:7
|
作者
Liu, Leening P. [1 ,2 ]
Hwang, Matthew [3 ]
Hung, Matthew [1 ]
Soulen, Michael C. [1 ]
Schaer, Thomas P. [4 ]
Shapira, Nadav [1 ]
Noel, Peter B. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[3] Reed Coll, Dept Phys, Portland, OR USA
[4] Univ Penn, Sch Vet Med, Dept Clin Studies, Philadelphia, PA USA
关键词
DUAL-ENERGY CT; THERMAL ABLATION THERAPY; COMPUTED-TOMOGRAPHY; MICROWAVE ABLATION; HEPATOCELLULAR-CARCINOMA; ATOMIC-NUMBER; LIVER-LESIONS; DENSITY; THERMOMETRY; FEASIBILITY;
D O I
10.1038/s41598-023-33264-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Spectral CT has been increasingly implemented clinically for its better characterization and quantification of materials through its multi-energy results. It also facilitates calculation of physical density, allowing for non-invasive mass measurements and temperature evaluations by manipulating the definition of physical density and thermal volumetric expansion, respectively. To develop spectral physical density quantifications, original and parametrized Alvarez-Macovski model and electron density-physical density model were validated with a phantom. The best physical density model was then implemented on clinical spectral CT scans of ex vivo bovine muscle to determine the accuracy and effect of acquisition parameters on mass measurements. In addition, the relationship between physical density and changes in temperature was evaluated by scanning and subjecting the tissue to a range of temperatures. The parametrized Alvarez-Macovski model performed best in both model development and validation with errors within +/- 0.02 g/mL. No effect from acquisition parameters was observed in mass measurements, which demonstrated accuracy with a maximum percent error of 0.34%. Furthermore, physical density was strongly correlated (R of 0.9781) to temperature changes through thermal volumetric expansion. Accurate and precise spectral physical density quantifications enable non-invasive mass measurements for pathological detection and temperature evaluation for thermal therapy monitoring in interventional oncology.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Prediction Of Rectal Temperature From Non-invasive Variables
    Havenith, George
    Richmond, Victoria L.
    Davey, Sarah
    Griggs, Katy
    Rayson, Mark P.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 186 - 186
  • [32] Non-Invasive Estimation of Temperature by Using Wavelet Transform
    Tellez, A.
    Leija, L.
    Vera, A.
    PAHCE: 2009 PAN AMERICAN HEALTH CARE EXCHANGES, 2009, : 77 - 81
  • [33] Evaluation of non-invasive sensors for monitoring core temperature
    Thomas, Shavin S.
    Flickinger, Katharyn L.
    Elmer, Jonathan
    Callaway, Clifton W.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2025,
  • [34] Measuring core body temperature with a non-invasive sensor
    Mazgaoker, Savyon
    Ketko, Itay
    Yanovich, Ran
    Heled, Yuval
    Epstein, Yoram
    JOURNAL OF THERMAL BIOLOGY, 2017, 66 : 17 - 20
  • [35] Non-invasive mapping of fluid temperature and flow in microsystems
    Cyca, MJ
    Spiewak, SA
    Hugo, RJ
    2005 International Conference on MEMS, NANO and Smart Systems, Proceedings, 2005, : 21 - 26
  • [36] Plasma deposited thermocouple for non-invasive temperature measurement
    Grassini, Sabrina
    Mombello, Domenico
    Neri, Alessandra
    Parvis, Marco
    Vallan, Alberto
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 708 - +
  • [37] Temperature influence on non-invasive blood glucose measurement
    Zhang, Xiqin
    Yeo, Joon Hock
    OPTICAL DIAGNOSTICS AND SENSING IX, 2009, 7186
  • [38] Non-invasive Muscle Temperature Control during Cooling
    Sipaviciene, S.
    Dumciene, A.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2013, 19 (09) : 42 - 45
  • [39] Non-invasive methods of body temperature measurements in rats
    Prior, Helen
    Motyer, Victoria
    Marks, Louise
    Cobey, Des
    Ewart, Lorna
    Valentin, Jean-Pierre
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2012, 66 (02) : 192 - 192
  • [40] Assessing rectal temperature with a novel non-invasive sensor
    Tsadok, Idan
    Scheinowitz, Mickey
    Shpitzer, Sagi Arieh
    Ketko, Itay
    Epstein, Yoram
    Yanovich, Ran
    JOURNAL OF THERMAL BIOLOGY, 2021, 95