Non-Invasive Measure of Stenosis Severity Through Spectral Analysis

被引:0
|
作者
Byers, Clayton P. [1 ]
Sinson, Alexandra M. [1 ]
Scheffers, Colette M. [1 ]
Ning, Taikang [1 ]
机构
[1] Trinity Coll, Dept Engn, Hartford, CT 06106 USA
关键词
stenosis; spectrum; internal flow; TURBULENCE;
D O I
10.1109/icsp48669.2020.9320947
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A preliminary study on the effect of stenosis severity in a restricted flow is performed through the spectral analysis of sound signals. A model pulsatile flow that uses differing area reductions through an opening was employed, where contact microphones secured outside of the reduction measured the sound intensity in the flow. A spectral analysis shows the narrowing results in increased magnitude of frequencies in the range of 15 to 170 Hz, with different narrowing cases resulting in different peak frequencies. Low frequency content up to 10 Hz remains approximately unchanged. This simplistic approach of signal processing forms a basis for enhanced understanding and diagnosis of the severity of narrowing in an internal flow, and encourages future research into more complicated bispectral methods of analysis. The results show a clear difference between "regular" turbulence present in an internal flow and "enhanced" turbulence due to a stenosis or similar restriction in the flow.
引用
收藏
页码:545 / 549
页数:5
相关论文
共 50 条
  • [1] NON-INVASIVE EVALUATION OF SEVERITY OF AORTIC-STENOSIS
    NAKAMURA, T
    HULTGREN, H
    FOWLES, R
    CLINICAL RESEARCH, 1983, 31 (01): : A80 - A80
  • [2] Aortic stenosis severity assessment: how to match non-invasive to invasive metrics
    Covolo, Elisa
    Razzolini, Renato
    Tarantini, Giuseppe
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2017, 18 (02) : 83 - 86
  • [3] Non-invasive examination techniques for determining the severity of a pulmonary stenosis in adults
    Eckert, S
    Fassbender, D
    Mannebach, H
    Bogunovic, N
    Miche, E
    Vogt, J
    Drose, K
    HERZ KREISLAUF, 1998, 30 (7-8): : 245 - 251
  • [4] NON-INVASIVE ASSESSMENT OF RENAL ARTERY STENOSIS SEVERITY IN THE INDIVIDUAL PATIENT
    Kips, Jan
    Van Bergen, Sarah
    Drieghe, Benny
    Devos, Dan
    Van Canneyt, Koen
    Trachet, Bram
    Van der Smissen, Benjamin
    Verdonck, Pascal
    Segers, Patrick
    ACTA CLINICA BELGICA, 2009, 64 (02): : 166 - 166
  • [5] SENSITIVITY AND SPECIFICITY OF NON-INVASIVE TESTS IN EVALUATING SEVERITY OF AORTIC-STENOSIS
    KENDRICK, M
    HARRINGTON, J
    PARISI, A
    CLINICAL RESEARCH, 1976, 24 (05): : A616 - A616
  • [6] NON-INVASIVE TESTS TO EVALUATE THE SEVERITY OF AORTIC-STENOSIS - LIMITATIONS AND RELIABILITY
    VOELKEL, AG
    KENDRICK, M
    PIETRO, DA
    VOELKEL, V
    GREENFIELD, D
    ASKENAZI, J
    FOLLAND, ED
    PARISI, AF
    CHEST, 1980, 77 (02) : 155 - 160
  • [7] Intravascular ultrasound (IVUS) validation of non-invasive and invasive measures of carotid stenosis severity in the CARUS Registry
    Musialek, P.
    Pieniazek, P.
    Tekieli, L.
    Przewlocki, T.
    Kablak-Ziembicka, A.
    Stepniewski, J.
    Moczulski, Z.
    Trystula, M.
    Tracz, W.
    Podolec, P.
    EUROPEAN HEART JOURNAL, 2012, 33 : 522 - 522
  • [8] NON-INVASIVE DETECTION OF CAROTID STENOSIS
    HOUCK, WS
    ARCHIVES OF SURGERY, 1982, 117 (04) : 515 - 515
  • [9] Computational analysis for non-invasive detection of stenosis in peripheral arteries
    Salman, Huseyin Enes
    Yazicioglu, Yigit
    MEDICAL ENGINEERING & PHYSICS, 2019, 70 : 39 - 50
  • [10] NON-INVASIVE EVALUATION OF SEVERITY OF VALVULAR AORTIC-STENOSIS BY A POINT SCORE SYSTEM
    NAKAMURA, T
    SHETTIGAR, U
    FOWLES, RE
    HULTGREN, HN
    AGE, 1982, 5 (04) : 138 - 139