Non-Invasive Measure of Stenosis Severity Through Spectral Analysis

被引:0
|
作者
Byers, Clayton P. [1 ]
Sinson, Alexandra M. [1 ]
Scheffers, Colette M. [1 ]
Ning, Taikang [1 ]
机构
[1] Trinity Coll, Dept Engn, Hartford, CT 06106 USA
关键词
stenosis; spectrum; internal flow; TURBULENCE;
D O I
10.1109/icsp48669.2020.9320947
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A preliminary study on the effect of stenosis severity in a restricted flow is performed through the spectral analysis of sound signals. A model pulsatile flow that uses differing area reductions through an opening was employed, where contact microphones secured outside of the reduction measured the sound intensity in the flow. A spectral analysis shows the narrowing results in increased magnitude of frequencies in the range of 15 to 170 Hz, with different narrowing cases resulting in different peak frequencies. Low frequency content up to 10 Hz remains approximately unchanged. This simplistic approach of signal processing forms a basis for enhanced understanding and diagnosis of the severity of narrowing in an internal flow, and encourages future research into more complicated bispectral methods of analysis. The results show a clear difference between "regular" turbulence present in an internal flow and "enhanced" turbulence due to a stenosis or similar restriction in the flow.
引用
收藏
页码:545 / 549
页数:5
相关论文
共 50 条
  • [21] Analysis of Invasive and Non-Invasive Meningiomas
    Croul, Sidney
    Salehi, Fateme
    Jalali, Shahrzad
    Burrell, Kelly
    Zadeh, Gelareh
    JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 2011, 70 (06): : 537 - 537
  • [22] NON-INVASIVE PREDICTION OF THE SEVERITY OF PULMONARY STENOSIS BY QUANTITATIVE TWO-DIMENSIONAL ECHO DOPPLER STUDIES
    SAHN, DJ
    LIMA, CO
    MENAHEM, S
    BARRON, JV
    GRENADIER, E
    VALDESCRUZ, LM
    GOLDBERG, SJ
    CIRCULATION, 1982, 66 (04) : 232 - 232
  • [23] NON-INVASIVE QUANTIFICATION OF SEVERITY OF AORTIC-STENOSIS BY ECHOCARDIOGRAPHIC WALL THICKNESS-RADIUS RATIO
    MOKOTOFF, DM
    QUINONES, MA
    WINTERS, WL
    MILLER, RR
    AMERICAN JOURNAL OF CARDIOLOGY, 1979, 43 (02): : 406 - 406
  • [24] Artificial intelligence approaches to predict coronary stenosis severity using non-invasive fractional flow reserve
    Carson, Jason M.
    Chakshu, Neeraj Kavan
    Sazonov, Igor
    Nithiarasu, Perumal
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (11) : 1337 - 1350
  • [25] Hyperemic flow velocity falls with worsening stenosis severity: the challenge for non-invasive predictors of coronary physiology
    Nijjer, S. S.
    De Waard, G.
    Sen, S.
    Petraco, R.
    Van de Hoef, T. P.
    Echavarria-Pinto, M.
    Escaned, J.
    Piek, J.
    Davies, J. E. R.
    Van Royen, N.
    EUROPEAN HEART JOURNAL, 2015, 36 : 299 - 299
  • [26] Analysis of pedestrian behaviors through non-invasive Bluetooth monitoring
    Yoshimura, Yuji
    Amini, Alexander
    Sobolevsky, Stanislav
    Blat, Josep
    Ratti, Carlo
    APPLIED GEOGRAPHY, 2017, 81 : 43 - 51
  • [27] A Novel Non-Invasive Screening Device for Aortic Stenosis
    Harb, Serge C.
    Kassab, Joseph
    Collier, Patrick H.
    Grimm, Richard A.
    Ramchand, Jay
    Kapadia, Samir R.
    CIRCULATION, 2023, 148
  • [28] Limitations of non-invasive ultrasound therapy for valve stenosis
    Ou, Dongbo
    Hu, Caiyou
    Huang, Shian
    LANCET, 2024, 404 (10453): : 653 - 653
  • [29] NON-INVASIVE DETECTION OF CAROTID STENOSIS FOLLOWING ENDARTERECTOMY
    CANTELMO, NL
    CUTLER, BS
    WHEELER, HB
    HERRMANN, JB
    CARDULLO, PA
    ARCHIVES OF SURGERY, 1981, 116 (08) : 1005 - 1008
  • [30] NON-INVASIVE ASSESSMENT OF VALVAR AORTIC-STENOSIS
    RITTER, S
    BOXER, R
    HUTCHEON, G
    GERSONY, W
    AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (04): : 974 - 974