Comparative energy analysis of cooling energy performance between conventional and hybrid air source internet data center cooling system

被引:2
|
作者
Lamptey, Nicholas Boafo [1 ]
Anka, Selorm Kwaku [1 ]
Cho, Yong [3 ]
Lee, Kwang Ho [2 ]
Choi, Jong Woong [3 ]
Choi, Jong Min [4 ]
机构
[1] Hanbat Natl Univ, Grad Sch Dept Mech Engn, Dept Mech Engn, Daejeon 34158, South Korea
[2] Korea Univ, Dept Architecture, Seoul 02741, South Korea
[3] K Water, Res Inst, Daejeon 34045, South Korea
[4] Hanbat Natl Univ, Dept Mech Engn, Daejeon 34158, South Korea
基金
新加坡国家研究基金会;
关键词
Data center; Coefficient of performance; Performance curve; Hybrid cooling; Part load ratio; COMPRESSION REFRIGERATION; SIDE ECONOMIZERS; HEAT-PIPE; EFFICIENCY; THERMOSIPHON; SIMULATION; DRIVEN; PUMP;
D O I
10.1016/j.enbuild.2023.113759
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The widespread need for data processing has led to an increase in internet data centers (IDCs), contributing to the generation of high heat loads and high energy usage. This study discusses a simulation model of a newly proposed cooling system applied to data centers for five selected climatic areas in South Korea. Using experimental data of the newly proposed system, performance correlations are developed by regression analysis method to estimate performance curve coefficients for energy modelling and simulation to predict the annual energy performance of the system and compare the performance with that of a conventional cooling system. The results showed an overall annual average energy efficiency of approximately 14.1% of the hybrid cooling system over the conventional cooling system. The mean seasonal coefficient of performance (SCOP) for the hybrid system and the conventional system is approximately 6.7 and 4.9 respectively for all cases in the winter period while a SCOP of 3.2 and 3.7 respectively for the summer period.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Comparative analysis and optimization of the annual performance for a novel internet data center cooling system
    Anka, Selorm Kwaku
    Lamptey, Nicholas Boafo
    Choi, Jong Min
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 67
  • [2] ENERGY PERFORMANCE ANALYSIS OF A COMBINED COOLING HEATING AND POWER SYSTEM FOR A DATA CENTER
    Xu, Donghao
    Qu, Ming
    [J]. PROCEEDINGS OF THE ASME 6TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY - 2012, PTS A AND B, 2012, : 203 - 208
  • [3] Energy Saving Analysis of Free Cooling System in the Data Center
    Yang, Yong
    Wang, Bo
    Zhou, Qinbin
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1815 - 1819
  • [4] COMPARATIVE THERMAL AND ENERGY ANALYSIS OF A HYBRID COOLING DATA CENTER WITH REAR DOOR HEAT EXCHANGERS
    Gao, Tianyi
    Samadiani, Emad
    Sammakia, Bahgat
    Schmidt, Roger
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2013, VOL 2, 2014,
  • [5] Energy efficiency optimization analysis for a cooling composite air conditioning system for internet data centers
    Li, Zhao
    Tong, Jihua
    Zheng, Zhuling
    Dong, Pengli
    Yang, Shangqing
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2024, 30 (09) : 1167 - 1181
  • [6] Performance and energy efficiency analysis of data center cooling plant by using lake water source
    Ling, Li
    Zhang, Quan
    Zeng, Liping
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3096 - 3103
  • [7] A Comparative Data Center Energy Efficiency and TCO Analysis for Different Cooling Technologies
    Heydari, Ali
    Eslami, Bahareh
    Chowdhury, Uschas
    Radmard, Vahideh
    Shahi, Pardeep
    Miyamura, Harold
    Tradat, Mohammad
    Chen, Peter
    Tuholski, Drew
    Gray, Kevin
    Buell, Tyler
    Stover, Greg
    Rodriguez, Jeremy
    [J]. PROCEEDINGS OF ASME 2023 INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, INTERPACK2023, 2023,
  • [8] Review on Cooling System Energy Consumption in Internet Data Centers
    Amoabeng, Kofi Owura
    Choi, Jong Min
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (04)
  • [9] Experimental performance analysis of a biogas energy assisted hybrid milk cooling system
    Coskun, Nevfel Yunus
    Atalay, Halil
    Coban, M. Turhan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 156 : 150 - 160
  • [10] Analysis of Air-Side Economizers in Terms of Cooling-Energy Performance in a Data Center Considering Exhaust Air Recirculation
    Park, Seonghyun
    Seo, Janghoo
    [J]. ENERGIES, 2018, 11 (02)