Energy Saving Analysis of Free Cooling System in the Data Center

被引:10
|
作者
Yang, Yong [1 ,2 ,3 ]
Wang, Bo [4 ]
Zhou, Qinbin [5 ]
机构
[1] Shandong Jianzhu Univ, Sch Thermal Engn, Jinan 250101, Shandong, Peoples R China
[2] Minist Educ, Key Lab Renewable Energy Technol Bldg, Jinan 250101, Shandong, Peoples R China
[3] Shandong Key Lab Renewable Energy Technol Bldg, Jinan 250101, Shandong, Peoples R China
[4] Qingdao Henghua Comp Room Equipment & Project Co, Qingdao 26600, Peoples R China
[5] Guohua Qixia Wind Power Generat Co Ltd, Yantai 264000, Peoples R China
关键词
Data center; Free cooling; Air conditioning system;
D O I
10.1016/j.proeng.2017.10.239
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years with the concept of Internet of things, cloud computing and mobile Internet, the large data center construction presents the fast growth the tendency in China, the air conditioning system energy consumption is too high, the problem is urgently needs to solve. Based on data center operation features of air conditioning system, in combination with the practical situation of engineering, free cooling mode was applied to air conditioning system, air conditioning energy consumption decreased significantly. (c) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1815 / 1819
页数:5
相关论文
共 50 条
  • [1] Experimental research and energy saving analysis of an integrated data center cooling and waste heat recovery system
    Chen, Xiaoxuan
    Wang, Xinyi
    Ding, Tao
    Li, Zhen
    [J]. APPLIED ENERGY, 2023, 352
  • [2] Radiative free cooling for energy and water saving in data centers
    Aili, Ablimit
    Long, Wenjun
    Cao, Zhiwei
    Wen, Yonggang
    [J]. APPLIED ENERGY, 2024, 359
  • [3] Free Cooling for Saving Energy: Technical Market Analysis of Dry, Wet, and Hybrid Cooling Based on Manufacturer Data
    Wenzel, Paula M.
    Muehlen, Marc
    Radgen, Peter
    [J]. ENERGIES, 2023, 16 (09)
  • [4] Energy saving analysis of evaporative cooling composite air conditioning system for data centers
    Han, Zongwei
    Sun, Xiaoqing
    Wei, Haotian
    Ji, Qiang
    Xue, Da
    [J]. APPLIED THERMAL ENGINEERING, 2021, 186
  • [5] Free cooling technologies for data centers: energy saving mechanism and applications
    Zhang, Yin
    Wei, Zhiyuan
    Zhang, Mingshan
    [J]. LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 : 410 - 415
  • [6] Energy saving evaluation of a novel energy system based on spray cooling for supercomputer center
    Chen, Hua
    Cheng, Wen-long
    Zhang, Wei-wei
    Peng, Yu-hang
    Jiang, Li-jia
    [J]. ENERGY, 2017, 141 : 304 - 315
  • [7] ENERGY PERFORMANCE ANALYSIS OF A COMBINED COOLING HEATING AND POWER SYSTEM FOR A DATA CENTER
    Xu, Donghao
    Qu, Ming
    [J]. PROCEEDINGS OF THE ASME 6TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY - 2012, PTS A AND B, 2012, : 203 - 208
  • [8] Energy-saving and economic analysis of the data center cooling system using magnetic bearing chillers under different climate conditions
    Dai, Yuande
    Liu, Jin
    Zou, Sikai
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [9] Free Cooling For Data Center
    Khattar, Mukesh K.
    [J]. ASHRAE JOURNAL, 2014, 56 (10) : 60 - +
  • [10] Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zones
    Lee, Kuei-Peng
    Chen, Hsiang-Lun
    [J]. ENERGY AND BUILDINGS, 2013, 64 : 103 - 112