Radiative free cooling for energy and water saving in data centers

被引:5
|
作者
Aili, Ablimit [1 ]
Long, Wenjun [1 ]
Cao, Zhiwei [1 ]
Wen, Yonggang [1 ]
机构
[1] Nanyang Technol Univ, Coll Engn, Singapore, Singapore
基金
新加坡国家研究基金会;
关键词
Radiative cooling; Free cooling; Data center; Energy saving; Water saving; Sustainable cooling; HVAC systems; HEAT-TRANSFER; FLOW; TEMPERATURE;
D O I
10.1016/j.apenergy.2024.122672
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Data centers consume large amounts of electricity and water specifically for cooling purposes. Integrating free cooling technologies is an essential part of broad efforts to reduce data centers' energy, carbon, and water footprints. Adding a new technique to the existing portfolio of free cooling technologies for data centers, we present how all -day passive radiative cooling can reduce energy and water consumptions of data centers. All -day passive radiative cooling is a free cooling technique, in which sky-facing surfaces with high solar reflectivity and midinfrared emissivity spontaneously reject heat into the sky, without consuming electricity and evaporating water. Using custom-built physics-based models, we simulate three configurations that integrate all -day radiative free cooling into data centers. We show that data center cooling energy and water consumptions differ substantially depending on the integration configuration. Particularly, direct free cooling of data center return air gives the highest energy saving with an annual average of around 20.0% under the tropical climate of Singapore which hosts a large number of data centers, whereas free cooling of compressed refrigerant prior to the chiller condenser gives the highest water saving with an annual average of around 84.0%. These results offer multiple viable options for integrating radiative free cooling into data center cooling systems to simultaneously achieve water and energy savings.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Free cooling technologies for data centers: energy saving mechanism and applications
    Zhang, Yin
    Wei, Zhiyuan
    Zhang, Mingshan
    [J]. LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 : 410 - 415
  • [2] Energy Saving Analysis of Free Cooling System in the Data Center
    Yang, Yong
    Wang, Bo
    Zhou, Qinbin
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1815 - 1819
  • [3] Energy Saving in Data Centers
    Bein, Wolfgang
    [J]. ELECTRONICS, 2018, 7 (01):
  • [4] Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zones
    Lee, Kuei-Peng
    Chen, Hsiang-Lun
    [J]. ENERGY AND BUILDINGS, 2013, 64 : 103 - 112
  • [5] Data centers cooling: A critical review of techniques, challenges, and energy saving solutions
    Alkrush, Ahmed A.
    Salem, Mohamed S.
    Abdelrehim, O.
    Hegazi, A. A.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 160 : 246 - 262
  • [6] Solar energy and free cooling potential in European data centers
    Malkamaki, Tuomo
    Ovaska, Seppo J.
    [J]. ANT 2012 AND MOBIWIS 2012, 2012, 10 : 1004 - 1009
  • [7] Energy saving analysis of evaporative cooling composite air conditioning system for data centers
    Han, Zongwei
    Sun, Xiaoqing
    Wei, Haotian
    Ji, Qiang
    Xue, Da
    [J]. APPLIED THERMAL ENGINEERING, 2021, 186
  • [8] Worldwide Energy Analysis of Major Free Cooling Methods for Data Centers
    Gozcu, Ozan
    Ozada, Berk
    Carfi, Muhammed Ugur
    Erden, Hamza Salih
    [J]. PROCEEDINGS OF THE 2017 SIXTEENTH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS ITHERM 2017, 2017, : 968 - 976
  • [9] Free cooling of data centers: A review
    Zhang, Hainan
    Shao, Shuangquan
    Xu, Hongbo
    Zou, Huiming
    Tian, Changqing
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 35 : 171 - 182
  • [10] Energy and economic assessment of major free cooling retrofits for data centers in Turkey
    Gozcu, Ozan
    Erden, Hamza Salih
    [J]. TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2019, 27 (03) : 2197 - 2212