Dual-layer spectral detector CT (SDCT) can improve the detection of mixed ground-glass lung nodules

被引:9
|
作者
Zhang, Zhenghua [1 ]
Yin, Fang [1 ]
Kang, Shaolei [1 ]
Tuo, Xiaoyu [2 ]
Zhang, Xiaodi [3 ]
Han, Dan [1 ]
机构
[1] Kunming Med Univ, Med Imaging Dept, Affiliated Hosp 1, Kunming, Peoples R China
[2] Kunming Med Univ, Pathol Dept, Affiliated Hosp 1, Kunming, Peoples R China
[3] Philips Healthcare, Chengdu, Peoples R China
关键词
Lung cancer; Pulmonary nodule; Adenocarcinoma; Computed tomography; OPACITY;
D O I
10.1007/s00432-022-04543-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Mixed ground-glass lung nodules are a high-risk factor for lung adenocarcinoma. This study aimed to analyze the value of SDCT electron density imaging in the detection of mixed ground-glass lung nodules (GGNs). Method 150 patients with GGNs confirmed by chest SDCT and surgical pathology were retrospectively analyzed. GGNs were screened by two senior radiologists by the double-blind method based on conventional CT and SDCT electron density images. Average CT values and electron density (ED) values of GGNs were measured for all, solid and ground-glass. Result Thirty pGGN cases determined by conventional CT were found to be mGGN on electron density images, including 23 in the invasive adenocarcinoma group (detection rate of 35.38%), which was significantly higher than that of the PGL group (14.89%, P < 0.05). In electron density images, average CT values and ED values in the PGL and invasive adenocarcinoma groups with pGGNs were no difference. The average CT value and ED value were significantly higher in the mGGN invasive adenocarcinoma group compared with the PGL group (P < 0.05). Meanwhile, ROC curve analysis of average CT value and ED value revealed AUC values for mGGN infiltration of 0.759 and 0.752. Conclusion SDCT can improve GGN visualization and increase the detection rate of mGGN compared with conventional CT. Attention should be paid to invasive adenocarcinoma for lung GGNs detected as mGGNs with high average CT value or ED value.
引用
收藏
页码:5901 / 5906
页数:6
相关论文
共 50 条
  • [11] Iodine Imaging at Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Dhanantwari, A.
    Halliburton, S.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657
  • [12] Dual-layer spectral detector computed tomography parameters can improve diagnostic efficiency of lung adenocarcinoma grading
    Mu, Ronghua
    Meng, Zhuoni
    Guo, Zixuan
    Qin, Xiaoyan
    Huang, Guangyi
    Yang, Xuri
    Jin, Hui
    Yang, Peng
    Zhang, Xiaodi
    Zhu, Xiqi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, : 4601 - 4611
  • [13] Objective Image Characterization of Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Halliburton, S.
    Dhanantwari, A.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3836 - 3836
  • [14] Diagnosis of benign and malignant thyroid nodules by a dual-layer spectral detector CT-based nomogram
    Yi, Rongqi
    Li, Ting
    Xie, Gang
    Li, Kang
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [15] Detection of malignant lesions in cytologically indeterminate thyroid nodules using a dual-layer spectral detector CT-clinical nomogram
    Ren, Xiaofang
    Zhang, Jiayan
    Song, Zuhua
    Li, Qian
    Zhang, Dan
    Li, Xiaojiao
    Yu, Jiayi
    Li, Zongwen
    Wen, Youjia
    Zeng, Dan
    Zhang, Xiaodi
    Tang, Zhuoyue
    FRONTIERS IN ONCOLOGY, 2024, 14
  • [16] Ground-Glass Nodules on Chest CT as Imaging Biomarkers in the Management of Lung Adenocarcinoma
    Goo, Jin Mo
    Park, Chang Min
    Lee, Hyun Ju
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (03) : 533 - 543
  • [17] Objective image characterization of a spectral CT scanner with dual-layer detector
    Ozguner, Orhan
    Dhanantwari, Amar
    Halliburton, Sandra
    Wen, Gezheng
    Utrup, Steven
    Jordan, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [18] The Application of Dual-layer Spectral Detector CT in Abdominal Vascular Imaging
    Lai, Lu-Yao
    Jiang, Ying
    Shu, Jian
    CURRENT MEDICAL IMAGING, 2023, 19 (14) : 1609 - 1615
  • [19] Noninvasive assessment of liver fibrosis by dual-layer spectral detector CT
    Morita, Koichiro
    Nishie, Akihiro
    Ushijima, Yasuhiro
    Takayama, Yukihisa
    Fujita, Nobuhiro
    Kubo, Yuichiro
    Ishimatsu, Keisuke
    Yoshizumi, Tomoharu
    Maehara, Junki
    Ishigami, Kousei
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [20] Assessment of solitary pulmonary nodules using dual-layer spectral detector computed tomography
    Ko, Tse-Pang
    Chang, Yu-Pin
    Chai, Jyh-Wen
    MEDICINE, 2024, 103 (41)