Background Mixed ground-glass lung nodules are a high-risk factor for lung adenocarcinoma. This study aimed to analyze the value of SDCT electron density imaging in the detection of mixed ground-glass lung nodules (GGNs). Method 150 patients with GGNs confirmed by chest SDCT and surgical pathology were retrospectively analyzed. GGNs were screened by two senior radiologists by the double-blind method based on conventional CT and SDCT electron density images. Average CT values and electron density (ED) values of GGNs were measured for all, solid and ground-glass. Result Thirty pGGN cases determined by conventional CT were found to be mGGN on electron density images, including 23 in the invasive adenocarcinoma group (detection rate of 35.38%), which was significantly higher than that of the PGL group (14.89%, P < 0.05). In electron density images, average CT values and ED values in the PGL and invasive adenocarcinoma groups with pGGNs were no difference. The average CT value and ED value were significantly higher in the mGGN invasive adenocarcinoma group compared with the PGL group (P < 0.05). Meanwhile, ROC curve analysis of average CT value and ED value revealed AUC values for mGGN infiltration of 0.759 and 0.752. Conclusion SDCT can improve GGN visualization and increase the detection rate of mGGN compared with conventional CT. Attention should be paid to invasive adenocarcinoma for lung GGNs detected as mGGNs with high average CT value or ED value.
引用
收藏
页码:5901 / 5906
页数:6
相关论文
共 50 条
  • [21] SNR performance comparison of dual-layer detector and dual-kVp spectral CT
    Heismann, B. J.
    Wirth, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3820 - 3822
  • [22] Dual-layer detector spectral CT-based machine learning models in the differential diagnosis of solitary pulmonary nodules
    Hui Lu
    Kaifang Liu
    Huan Zhao
    Yongqiang Wang
    Bo Shi
    Scientific Reports, 14
  • [23] Dual-layer detector spectral CT-based machine learning models in the differential diagnosis of solitary pulmonary nodules
    Lu, Hui
    Liu, Kaifang
    Zhao, Huan
    Wang, Yongqiang
    Shi, Bo
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [24] A new scheme for computer-aided detection of CT lung nodules designed in consideration of ground-glass opacity
    Matsumoto, Sumiaki
    Ohno, Yoshiharu
    Yamagata, Hitoshi
    Asahina, Hiroshi
    Sugimura, Kazuro
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 352 - 354
  • [25] CT quantitative parameters to predict the invasiveness of lung pure ground-glass nodules (pGGNs)
    Han, L.
    Zhang, P.
    Wang, Y.
    Gao, Z.
    Wang, H.
    Li, X.
    Ye, Z.
    CLINICAL RADIOLOGY, 2018, 73 (05) : 504.e1 - 504.e7
  • [26] Dual-energy CT-based radiomics for predicting invasiveness of lung adenocarcinoma appearing as ground-glass nodules
    Zheng, Yuting
    Han, Xiaoyu
    Jia, Xi
    Ding, Chengyu
    Zhang, Kailu
    Li, Hanting
    Cao, Xuexiang
    Zhang, Xiaohui
    Zhang, Xin
    Shi, Heshui
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [27] Diagnostic value of dual-layer spectral detector CT in differentiating lung adenocarcinoma from squamous cell carcinoma
    Mu, Ronghua
    Meng, Zhuoni
    Guo, Zixuan
    Qin, Xiaoyan
    Huang, Guangyi
    Yang, Xuri
    Jin, Hui
    Yang, Peng
    Deng, Meimei
    Zhang, Xiaodi
    Zhu, Xiqi
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [28] Improvement of Breast Cancer Detection Using Dual-Layer Spectral CT
    Hasse, Felix Christian
    Giannakis, Athanasios
    Wehrse, Eckhard
    Stiller, Wolfram
    Wallwiener, Markus
    Kauczor, Hans-Ulrich
    Weber, Tim F.
    Heil, Jorg
    Mokry, Theresa
    DIAGNOSTICS, 2024, 14 (14)
  • [29] Case study of an autoantibody panel for early detection of lung cancer and ground-glass nodules
    Yunli Huo
    Zijian Guo
    Xuehui Gao
    Zhongjuan Liu
    Ruili Zhang
    Xuzhen Qin
    Journal of Cancer Research and Clinical Oncology, 2020, 146 : 3349 - 3357
  • [30] Case study of an autoantibody panel for early detection of lung cancer and ground-glass nodules
    Huo, Yunli
    Guo, Zijian
    Gao, Xuehui
    Liu, Zhongjuan
    Zhang, Ruili
    Qin, Xuzhen
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2020, 146 (12) : 3349 - 3357