Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics

被引:0
|
作者
Lee, Gyu-Han [1 ]
Koo, Hyun Jung [2 ]
Park, Kyung Jin [2 ,3 ]
Yang, Dong Hyun [2 ]
Ha, Hojin [4 ]
机构
[1] Kangwon Natl Univ, Dept Interdisciplinary Program Biohlth Machinery C, Chunchon, South Korea
[2] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Dept Radiol,Coll Med, Seoul, South Korea
[3] Yonsei Univ, Dept Elect & Elect Engn, Seoul, South Korea
[4] Kangwon Natl Univ, Dept Smart Hlth Sci & Technol, Chunchon, South Korea
基金
新加坡国家研究基金会;
关键词
Fontan circulation; 4D Flow MRI; computational fluid dynamics; blood flow distribution; hemodynamics; CARDIAC MAGNETIC-RESONANCE; BLOOD-FLOW; ENERGY-LOSS; KINETIC-ENERGY; RESOLUTION;
D O I
10.3389/fphys.2023.1199771
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction: The aim of this study was to characterize the hemodynamics of Fontan patients using both four-dimensional flow magnetic resonance imaging (4D Flow MRI) and computational fluid dynamics (CFD). Methods: Twenty-nine patients (3.5 +/- 0.5 years) who had undergone the Fontan procedure were enrolled, and the superior vena cava (SVC), left pulmonary artery (LPA), right pulmonary artery (RPA), and conduitwere segmented based on 4D Flow MRI images. Velocity fields from4D Flow MRI were used as boundary conditions for CFD simulations. Hemodynamic parameters such as peak velocity (Vmax), pulmonary flow distribution (PFD), kinetic energy (KE), and viscous dissipation (VD) were estimated and compared between the two modalities. Results and discussion: The Vmax, KE, VD, PFDTotal to LPA, and PFDTotal to RPA of the Fontan circulation were 0.61 +/- 0.18 m/s, 0.15 +/- 0.04 mJ, 0.14 +/- 0.04 mW, 41.3 +/- 15.7%, and 58.7 +/- 15.7% from 4D Flow MRI; and 0.42 +/- 0.20 m/s, 0.12 +/- 0.05 mJ, 0.59 +/- 0.30 mW, 40.2 +/- 16.4%, and 59.8 +/- 16.4% from CFD, respectively. The overall velocity field, KE, and PFD from the SVC were in agreement between modalities. However, PFD from the conduit and VD showed a large discrepancy between 4D Flow MRI and CFD, most likely due to spatial resolution and data noise. This study highlights the necessity for careful consideration when analyzing hemodynamic data from different modalities in Fontan patients.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Blood flow analysis with computational fluid dynamics and 4D-flow MRI for vascular diseases
    Kamada, Hiroki
    Nakamura, Masanori
    Ota, Hideki
    Higuchi, Satoshi
    Takase, Kei
    JOURNAL OF CARDIOLOGY, 2022, 80 (05) : 386 - 396
  • [32] Quantitative evaluation of pulmonary hypertension using 4D flow MRI: A retrospective study
    Koike, Hirofumi
    Nishimura, Takamasa
    Morikawa, Minoru
    HELIYON, 2024, 10 (10)
  • [33] Comparison of Immersed Boundary Simulations of Heart Valve Hemodynamics Against In Vitro 4D Flow MRI Data
    Alexander D. Kaiser
    Nicole K. Schiavone
    Christopher J. Elkins
    Doff B. McElhinney
    John K. Eaton
    Alison L. Marsden
    Annals of Biomedical Engineering, 2023, 51 : 2267 - 2288
  • [34] Comparison of Immersed Boundary Simulations of Heart Valve Hemodynamics Against In Vitro 4D Flow MRI Data
    Kaiser, Alexander D.
    Schiavone, Nicole K.
    Elkins, Christopher J.
    McElhinney, Doff B.
    Eaton, John K.
    Marsden, Alison L.
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (10) : 2267 - 2288
  • [35] Hemodynamics in normal cerebral arteries: qualitative comparison of 4D phase-contrast magnetic resonance and image-based computational fluid dynamics
    Juan R. Cebral
    Christopher M. Putman
    Marcus T. Alley
    Thomas Hope
    Roland Bammer
    Fernando Calamante
    Journal of Engineering Mathematics, 2009, 64
  • [36] Hemodynamics in normal cerebral arteries: qualitative comparison of 4D phase-contrast magnetic resonance and image-based computational fluid dynamics
    Cebral, Juan R.
    Putman, Christopher M.
    Alley, Marcus T.
    Hope, Thomas
    Bammer, Roland
    Calamante, Fernando
    JOURNAL OF ENGINEERING MATHEMATICS, 2009, 64 (04) : 367 - 378
  • [37] Editorial on "Quantification of Hemodynamics of Cerebral Arteriovenous Malformations After Stereotactic Radiosurgery Using 4D Flow MRI"
    Bergsland, Niels
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (06) : 1851 - 1852
  • [38] Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images
    Scott MacDonald Black
    Craig Maclean
    Pauline Hall Barrientos
    Konstantinos Ritos
    Asimina Kazakidi
    Cardiovascular Engineering and Technology, 2023, 14 : 655 - 676
  • [39] Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images
    Black, Scott MacDonald
    Maclean, Craig
    Barrientos, Pauline Hall
    Ritos, Konstantinos
    Kazakidi, Asimina
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2023, 14 (5) : 655 - 676
  • [40] Validation of Computational Fluid Dynamics Methods with Anatomically Exact, 3D Printed MRI Phantoms and 4D pcMRI
    Anderson, Jeff R.
    Diaz, Orlando
    Klucznik, Richard
    Zhang, Y. Jonathan
    Britz, Gavin W.
    Grossman, Robert G.
    Lv, Nan
    Huang, Qinghai
    Karmonik, Christof
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6699 - 6701