Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics

被引:0
|
作者
Lee, Gyu-Han [1 ]
Koo, Hyun Jung [2 ]
Park, Kyung Jin [2 ,3 ]
Yang, Dong Hyun [2 ]
Ha, Hojin [4 ]
机构
[1] Kangwon Natl Univ, Dept Interdisciplinary Program Biohlth Machinery C, Chunchon, South Korea
[2] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Dept Radiol,Coll Med, Seoul, South Korea
[3] Yonsei Univ, Dept Elect & Elect Engn, Seoul, South Korea
[4] Kangwon Natl Univ, Dept Smart Hlth Sci & Technol, Chunchon, South Korea
基金
新加坡国家研究基金会;
关键词
Fontan circulation; 4D Flow MRI; computational fluid dynamics; blood flow distribution; hemodynamics; CARDIAC MAGNETIC-RESONANCE; BLOOD-FLOW; ENERGY-LOSS; KINETIC-ENERGY; RESOLUTION;
D O I
10.3389/fphys.2023.1199771
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction: The aim of this study was to characterize the hemodynamics of Fontan patients using both four-dimensional flow magnetic resonance imaging (4D Flow MRI) and computational fluid dynamics (CFD). Methods: Twenty-nine patients (3.5 +/- 0.5 years) who had undergone the Fontan procedure were enrolled, and the superior vena cava (SVC), left pulmonary artery (LPA), right pulmonary artery (RPA), and conduitwere segmented based on 4D Flow MRI images. Velocity fields from4D Flow MRI were used as boundary conditions for CFD simulations. Hemodynamic parameters such as peak velocity (Vmax), pulmonary flow distribution (PFD), kinetic energy (KE), and viscous dissipation (VD) were estimated and compared between the two modalities. Results and discussion: The Vmax, KE, VD, PFDTotal to LPA, and PFDTotal to RPA of the Fontan circulation were 0.61 +/- 0.18 m/s, 0.15 +/- 0.04 mJ, 0.14 +/- 0.04 mW, 41.3 +/- 15.7%, and 58.7 +/- 15.7% from 4D Flow MRI; and 0.42 +/- 0.20 m/s, 0.12 +/- 0.05 mJ, 0.59 +/- 0.30 mW, 40.2 +/- 16.4%, and 59.8 +/- 16.4% from CFD, respectively. The overall velocity field, KE, and PFD from the SVC were in agreement between modalities. However, PFD from the conduit and VD showed a large discrepancy between 4D Flow MRI and CFD, most likely due to spatial resolution and data noise. This study highlights the necessity for careful consideration when analyzing hemodynamic data from different modalities in Fontan patients.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Bulk Flow and Near Wall Hemodynamics of the Rabbit Aortic Arch and Descending Thoracic Aorta: A 4D PC-MRI Derived Computational Fluid Dynamics Study
    Molony, D. S.
    Park, J.
    Zhou, L.
    Fleischer, C. C.
    Sun, H. Y.
    Hu, X. P.
    Oshinski, J. N.
    Samady, H.
    Giddens, D. P.
    Rezvan, A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (01):
  • [12] Cerebral Hemodynamics Comparison between Transcranial Doppler Ultrasound and 4D Flow MRI
    Fico, Brandon
    Miller, Kathleen
    Rivera-Rivera, Leonardo
    Corkery, Adam
    Pearson, Andrew
    Loggie, Nicole
    Howery, Anna
    Rowley, Howard
    Johnson, Kevin
    Johnson, Sterling
    Weiben, Oliver
    Barnes, Jill
    PHYSIOLOGY, 2023, 38
  • [13] Cerebral hemodynamics comparison using transcranial doppler ultrasound and 4D flow MRI
    Fico, Brandon G.
    Miller, Kathleen B.
    Rivera-Rivera, Leonardo A.
    Corkery, Adam T.
    Pearson, Andrew G.
    Loggie, Nicole A.
    Howery, Anna J.
    Rowley, Howard A.
    Johnson, Kevin M.
    Johnson, Sterling C.
    Wieben, Oliver
    Barnes, Jill N.
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [14] Comparison of 2D and 4D Flow MRI Measurements for Hemodynamic Evaluation of the Fontan Palliation
    Listo, Elisa
    Martini, Nicola
    Salvadori, Stefano
    Valenti, Elisa
    Stagnaro, Nicola
    Trocchio, Gianluca
    Marrone, Chiara
    Clemente, Alberto
    Raimondi, Francesca
    Festa, Pierluigi
    Ali, Lamia Ait
    CONGENITAL HEART DISEASE, 2023, 18 (06) : 627 - 638
  • [15] Merging computational fluid dynamics and 4D Flow MRI using proper orthogonal decomposition and ridge regression
    Bakhshinejad, Ali
    Baghaie, Ahmadreza
    Vali, Alireza
    Saloner, David
    Rayz, Vitaliy L.
    D'Souza, Roshan M.
    JOURNAL OF BIOMECHANICS, 2017, 58 : 162 - 173
  • [16] 4DFlowNet: Super-Resolution 4D Flow MRI Using Deep Learning and Computational Fluid Dynamics
    Ferdian, Edward
    Suinesiaputra, Avan
    Dubowitz, David J.
    Zhao, Debbie
    Wang, Alan
    Cowan, Brett
    Young, Alistair A.
    FRONTIERS IN PHYSICS, 2020, 8
  • [17] A 4D flow MRI evaluation of the impact of shear-dependent fluid viscosity on in vitro Fontan circulation flow
    Cheng, Andrew L.
    Wee, Choo Phei
    Pahlevan, Niema M.
    Wood, John C.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2019, 317 (06): : H1243 - H1253
  • [18] 4D Flow MRI Analysis of the Left Atrial Hemodynamics After Atrial Fibrillation Surgery
    Maeda, Motohiro
    Sakamoto, Shunichiro
    Hiromoto, Atsushi
    Suzuki, Kenji
    Ishii, Yosuke
    CIRCULATION, 2023, 148
  • [19] Compressed-sensing accelerated 4D flow MRI of cerebrospinal fluid dynamics
    Elena Jaeger
    Kristina Sonnabend
    Frank Schaarschmidt
    David Maintz
    Kilian Weiss
    Alexander C. Bunck
    Fluids and Barriers of the CNS, 17
  • [20] Compressed-sensing accelerated 4D flow MRI of cerebrospinal fluid dynamics
    Jaeger, Elena
    Sonnabend, Kristina
    Schaarschmidt, Frank
    Maintz, David
    Weiss, Kilian
    Bunck, Alexander C.
    FLUIDS AND BARRIERS OF THE CNS, 2020, 17 (01)