Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images

被引:4
|
作者
Black, Scott MacDonald [1 ]
Maclean, Craig [2 ]
Barrientos, Pauline Hall [3 ]
Ritos, Konstantinos [4 ,5 ]
Kazakidi, Asimina [1 ]
机构
[1] Univ Strathclyde, Dept Biomed Engn, Glasgow City, Scotland
[2] Terumo Aort, Res & Dev, Glasgow City, Scotland
[3] Queen Elizabeth Univ Hosp, Clin Phys, NHS Greater Glasgow & Clyde, Glasgow City, Scotland
[4] Dept Mech & Aerosp Engn, Glasgow City, Scotland
[5] Univ Thessaly, Dept Mech Engn, Volos, Greece
基金
英国工程与自然科学研究理事会; 英国科研创新办公室;
关键词
4D Flow-MRI; CT; Aorta; Segmentation; Reconstruction; CFD; WALL SHEAR-STRESS; MAGNETIC-RESONANCE ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; CT ANGIOGRAPHY; RADIATION RISK; BLOOD-FLOW; SEGMENTATION; GADOLINIUM; AORTA; HEMODYNAMICS;
D O I
10.1007/s13239-023-00679-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Segmentation and reconstruction of arterial blood vessels is a fundamental step in the translation of computational fluid dynamics (CFD) to the clinical practice. Four-dimensional flow magnetic resonance imaging (4D Flow-MRI) can provide detailed information of blood flow but processing this information to elucidate the underlying anatomical structures is challenging. In this study, we present a novel approach to create high-contrast anatomical images from retrospective 4D Flow-MRI data.Methods For healthy and clinical cases, the 3D instantaneous velocities at multiple cardiac time steps were superimposed directly onto the 4D Flow-MRI magnitude images and combined into a single composite frame. This new Composite Phase-Contrast Magnetic Resonance Angiogram (CPC-MRA) resulted in enhanced and uniform contrast within the lumen. These images were subsequently segmented and reconstructed to generate 3D arterial models for CFD. Using the time-dependent, 3D incompressible Reynolds-averaged Navier-Stokes equations, the transient aortic haemodynamics was computed within a rigid wall model of patient geometries.Results Validation of these models against the gold standard CT-based approach showed no statistically significant inter-modality difference regarding vessel radius or curvature (p > 0.05), and a similar Dice Similarity Coefficient and Hausdorff Distance. CFD-derived near-wall hemodynamics indicated a significant inter-modality difference (p > 0.05), though these absolute errors were small. When compared to the in vivo data, CFD-derived velocities were qualitatively similar.Conclusion This proof-of-concept study demonstrated that functional 4D Flow-MRI information can be utilized to retrospectively generate anatomical information for CFD models in the absence of standard imaging datasets and intravenous contrast.
引用
收藏
页码:655 / 676
页数:22
相关论文
共 50 条
  • [1] Reconstruction and Validation of Arterial Geometries for Computational Fluid Dynamics Using Multiple Temporal Frames of 4D Flow-MRI Magnitude Images
    Scott MacDonald Black
    Craig Maclean
    Pauline Hall Barrientos
    Konstantinos Ritos
    Asimina Kazakidi
    Cardiovascular Engineering and Technology, 2023, 14 : 655 - 676
  • [2] Establishing the distribution of cerebrovascular resistance using computational fluid dynamics and 4D flow MRI
    Vikstrom, Axel
    Holmlund, Petter
    Holmgren, Madelene
    Wahlin, Anders
    Zarrinkoob, Laleh
    Malm, Jan
    Eklund, Anders
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [3] ESTIMATION OF WALL SHEAR STRESS USING 4D FLOW CARDIOVASCULAR MRI AND COMPUTATIONAL FLUID DYNAMICS
    Soudah, E.
    Casacuberta, J.
    Gamez-Montero, P. J.
    Perez, J. S.
    Rodriguez-Cancio, M.
    Raush, G.
    Li, C. H.
    Carreras, F.
    Castilla, R.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (03)
  • [4] Thoracic aortic aneurysm: 4D flow MRI and computational fluid dynamics model
    Callaghan, F. M.
    Karkouri, J.
    Broadhouse, K.
    Evin, M.
    Fletcher, D. F.
    Grieve, S. M.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 : 1894 - 1895
  • [5] Merging computational fluid dynamics and 4D Flow MRI using proper orthogonal decomposition and ridge regression
    Bakhshinejad, Ali
    Baghaie, Ahmadreza
    Vali, Alireza
    Saloner, David
    Rayz, Vitaliy L.
    D'Souza, Roshan M.
    JOURNAL OF BIOMECHANICS, 2017, 58 : 162 - 173
  • [6] New imaging tools in cardiovascular medicine: computational fluid dynamics and 4D flow MRI
    Itatani, Keiichi
    Miyazaki, Shohei
    Furusawa, Tokoki
    Numata, Satoshi
    Yamazaki, Sachiko
    Morimoto, Kazuki
    Makino, Rina
    Morichi, Hiroko
    Nishino, Teruyasu
    Yaku, Hitoshi
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2017, 65 (11) : 611 - 621
  • [7] Hemodynamic Evaluation of Intracranial Aneurysm: Comparison of Computational Fluid Dynamics with 4D Flow MRI
    Misaki, Kouichi
    Futami, Kazuya
    Uno, Takehiro
    Nambu, Iku
    Yoshikawa, Akifumi
    Kamide, Tomoya
    Nakada, Mitsutoshi
    NEUROSURGERY, 2020, 67 : 120 - 121
  • [8] New imaging tools in cardiovascular medicine: computational fluid dynamics and 4D flow MRI
    Keiichi Itatani
    Shohei Miyazaki
    Tokoki Furusawa
    Satoshi Numata
    Sachiko Yamazaki
    Kazuki Morimoto
    Rina Makino
    Hiroko Morichi
    Teruyasu Nishino
    Hitoshi Yaku
    General Thoracic and Cardiovascular Surgery, 2017, 65 : 611 - 621
  • [9] 4DFlowNet: Super-Resolution 4D Flow MRI Using Deep Learning and Computational Fluid Dynamics
    Ferdian, Edward
    Suinesiaputra, Avan
    Dubowitz, David J.
    Zhao, Debbie
    Wang, Alan
    Cowan, Brett
    Young, Alistair A.
    FRONTIERS IN PHYSICS, 2020, 8
  • [10] Accelerated sequences of 4D flow MRI using GRAPPA and compressed sensing: A comparison against conventional MRI and computational fluid dynamics
    Garreau, Morgane
    Puiseux, Thomas
    Toupin, Solenn
    Giese, Daniel
    Mendez, Simon
    Nicoud, Franck
    Moreno, Ramiro
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2432 - 2446