Dose Planning Evaluation of Intensity-Modulated Proton Therapy (IMPT) Technique Based on In-House Dynamic Thorax Phantom

被引:0
|
作者
Vernanda, V. [1 ]
Pawiro, S. A. [1 ]
机构
[1] Univ Indonesia, Fac Math & Nat Sci, Dept Phys, Depok 16424, West Java, Indonesia
关键词
NSCLC; IMPT; Treatment planning; Bragg-peak; IMRT; TPS;
D O I
10.55981/aij.2023.1196
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
One of the drawbacks of the Intensity Modulated Radiation Therapy (IMRT) technique is that the absorbed dose in healthy tissue is relatively high. Proton beam has characteristics that can compensate for these drawbacks. The Bragg peak characteristic of a proton beam allows the administration of high radiation doses to the target organ only. Non-Small Cell Lung Cancer (NSCLC) cases are located in the vicinity of many vital organs, so radiation doses that exceed a certain limit will have a significant impact on these organs. Proton is a heavy particle that exhibits interaction patterns with tissue heterogeneity that differ from that of photon. This study aims to determine the distribution of proton beam planning doses in the NSCLC cases with the Intensity Modulated Proton Therapy (IMPT) technique and compare its effectiveness with the IMRT technique. Treatment planning was done by using TPS Eclipse on the water phantom and on the in-house thorax dynamic phantom. The water phantom planning parameters used are one field at 0 degrees and three fields at 45 degrees, 135 degrees, and 225 degrees. In this study, a single, sum, and multiple field techniques on the in-house thorax dynamic phantom were used. The evaluation was performed by calculating Conformity Index (CI), Homogeneity Index (HI), and Gradient Index (GI) parameters for each treatment planning. As a result, a bit of difference in the CI the HI values are shown between IMPT and IMRT planning. The GI values of IMPT planning are in the range between 4.15-4.53, while the GI value of IMRT is 7.89. The histogram results of the planar dose distribution show that the IMPT treatment planning provides fewer off-target organ doses than the IMRT planning. Evaluation was also carried out on the IMPT treatment planning of target organs in five areas of interest and four OAR positions. The evaluation results were then compared with the IMRT measurement data. As a result, the value of the point doses at the target organ did not differ significantly. However, the absorbed dose with the IMPT technique at four OAR positions is nearly zero, which had a large difference compared to the IMRT technique.(c) 2023 Atom Indonesia. All rights reserved
引用
收藏
页码:7 / 11
页数:5
相关论文
共 50 条
  • [41] Intensity-modulated x-ray (IMXT) versus proton (IMPT) therapy for theragnostic hypoxia-based dose painting (vol 53, pg 4153, 2008)
    Flynn, Ryan T.
    Bowen, Stephen R.
    Bentzen, Soren M.
    Mackie, T. Rockwell
    Jeraj, Robert
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06): : 1847 - 1847
  • [42] Development and Evaluation of Multipurpose Phantom for Delivery Quality Assurance of Intensity-modulated Radiation Therapy
    Jang, Jae-Uk
    Han, Man-Seok
    Kim, Ki-Hwan
    Jeon, Min-Cheol
    Hwang, Ui-Jung
    JOURNAL OF MAGNETICS, 2022, 27 (04) : 430 - 439
  • [43] DEVELOPMENT AND EVALUATION OF A PHANTOM FOR MULTI-PURPOSE DOSIMETRY IN INTENSITY-MODULATED RADIATION THERAPY
    Jeong, Hae Sun
    Han, Youngyih
    Kum, Oyeon
    Kim, Chan Hyeong
    Park, Joo Hwan
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2011, 43 (04) : 399 - 404
  • [44] Sparsity constrained split feasibility for dose-volume constraints in inverse planning of intensity-modulated photon or proton therapy
    Penfold, Scott
    Zalas, Rafal
    Casiraghi, Margherita
    Brooke, Mark
    Censor, Yair
    Schulte, Reinhard
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09): : 3599 - 3618
  • [45] Multiple Energy Extraction Delivery Technique in Synchrotron-Based Intensity-Modulated Proton Therapy (IMPT) May Exacerbate Motion Interplay Effects for Lung Cancer Treatment
    Younkin, Je
    Morales, D. Hernandez
    Shen, J.
    Ding, X.
    Stoker, Jb
    Bues, M.
    Fatyga, M.
    Sio, Tt
    Schild, Se
    Liu, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E471 - E471
  • [46] Effectiveness of robust optimization in intensity-modulated proton therapy planning for head and neck cancers
    Liu, Wei
    Frank, Steven J.
    Li, Xiaoqiang
    Li, Yupeng
    Park, Peter C.
    Dong, Lei
    Zhu, X. Ronald
    Mohan, Radhe
    MEDICAL PHYSICS, 2013, 40 (05)
  • [47] Investigating the utilization of beam-specific apertures for the intensity-modulated proton therapy (IMPT) head and neck cancer plans
    Rana, Suresh
    Storey, Mark
    Padannayil, Noufal Manthala
    Shamurailatpam, Dayananda Sharma
    Bennouna, Jaafar
    George, Jerry
    Chang, John
    MEDICAL DOSIMETRY, 2021, 46 (02) : E7 - E11
  • [48] Analytical incorporation of fractionation effects in probabilistic treatment planning for intensity-modulated proton therapy
    Wahl, Niklas
    Hennig, Philipp
    Wieser, Hans-Peter
    Bangert, Mark
    MEDICAL PHYSICS, 2018, 45 (04) : 1317 - 1328
  • [49] Assessing a set of optimal user interface parameters for intensity-modulated proton therapy planning
    Hillbrand, Martin
    Georg, Dietmar
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (04): : 93 - 104
  • [50] A quality control method for intensity-modulated radiation therapy planning based on generalized equivalent uniform dose
    Pang, Haowen
    Sun, Xiaoyang
    Yang, Bo
    Wu, Jingbo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 276 - 282