Sparsity constrained split feasibility for dose-volume constraints in inverse planning of intensity-modulated photon or proton therapy

被引:19
|
作者
Penfold, Scott [1 ,2 ]
Zalas, Rafal [3 ]
Casiraghi, Margherita [4 ]
Brooke, Mark [2 ]
Censor, Yair [5 ]
Schulte, Reinhard [6 ]
机构
[1] Royal Adelaide Hosp, Dept Med Phys, Adelaide, SA 5000, Australia
[2] Univ Adelaide, Dept Phys, Adelaide, SA 5005, Australia
[3] Technion, Dept Math, IL-32000 Haifa, Israel
[4] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[5] Univ Haifa Mt Carmel, Dept Math, IL-3498838 Haifa, Israel
[6] Loma Linda Univ, Sch Med, Dept Basic Sci, Loma Linda, CA 92350 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 09期
基金
美国国家卫生研究院;
关键词
dose-volume constraints; intensity-modulated proton therapy; sparsity constraints; split feasibility; inverse planning; automatic relaxation method; CQ-algorithm; LINEAR-PROGRAMMING APPROACH; RADIATION-THERAPY; RELAXATION METHOD; OPTIMIZATION; PROJECTION; RADIOTHERAPY; ALGORITHMS; CANCER; IMRT; SETS;
D O I
10.1088/1361-6560/aa602b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A split feasibility formulation for the inverse problem of intensity-modulated radiation therapy treatment planning with dose-volume constraints included in the planning algorithm is presented. It involves a new type of sparsity constraint that enables the inclusion of a percentage-violation constraint in the model problem and its handling by continuous (as opposed to integer) methods. We propose an iterative algorithmic framework for solving such a problem by applying the feasibility-seeking CQ-algorithm of Byrne combined with the automatic relaxation method that uses cyclic projections. Detailed implementation instructions are furnished. Functionality of the algorithm was demonstrated through the creation of an intensity-modulated proton therapy plan for a simple 2D C-shaped geometry and also for a realistic base-of-skull chordoma treatment site. Monte Carlo simulations of proton pencil beams of varying energy were conducted to obtain dose distributions for the 2D test case. A research release of the Pinnacle(3) proton treatment planning system was used to extract pencil beam doses for a clinical base-of-skull chordoma case. In both cases the beamlet doses were calculated to satisfy dose-volume constraints according to our new algorithm. Examination of the dose-volume histograms following inverse planning with our algorithm demonstrated that it performed as intended. The application of our proposed algorithm to dose-volume constraint inverse planning was successfully demonstrated. Comparison with optimized dose distributions from the research release of the Pinnacle(3) treatment planning system showed the algorithm could achieve equivalent or superior results.
引用
收藏
页码:3599 / 3618
页数:20
相关论文
共 50 条
  • [1] Mixed integer programming with dose-volume constraints in intensity-modulated proton therapy
    Zhang, Pengfei
    Fan, Neng
    Shan, Jie
    Schild, Steven E.
    Bues, Martin
    Liu, Wei
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 29 - 35
  • [2] Dose-volume constrained optimization in intensity-modulated radiation therapy treatment planning
    Yoshihiro Tanaka
    Ken’ichi Fujimoto
    Tetsuya Yoshinaga
    [J]. Journal of Inequalities and Applications, 2015
  • [3] Dose-volume constrained optimization in intensity-modulated radiation therapy treatment planning
    Tanaka, Yoshihiro
    Fujimoto, Ken'ichi
    Yoshinaga, Tetsuya
    [J]. JOURNAL OF INEQUALITIES AND APPLICATIONS, 2015, : 1 - 13
  • [4] Dose-volume comparison of proton therapy and intensity-modulated radiotherapy for prostate cancer
    Vargas, Carlos
    Fryer, Amber
    Mahajan, Chaitali
    Indelicato, Daniel
    Horne, David
    Chellini, Angela
    Mckenzie, Craig
    Lawlor, Paula
    Henderson, Randal
    Li, Zuofeng
    Lin, Liyong
    Olivier, Kenneth
    Keole, Sameer
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (03): : 744 - 751
  • [5] DOSE-VOLUME ANALYSIS OF WHOLE VENTRICULAR IRRADIATION BY PROTON BEAM COMPARING WITH INTENSITY-MODULATED RADIOTHERAPY AND STANDARD PHOTON THERAPY
    Fuji, Hiroshi
    Nakasu, Yoko
    Horiguchi, Satoshi
    Mitsuya, Koich
    Ishida, Yuji
    Murayama, Shigeyuki
    [J]. NEURO-ONCOLOGY, 2009, 11 (06) : 969 - 969
  • [6] Dose-volume specification: New challenges with intensity-modulated radiation therapy
    Purdy, JA
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) : 199 - 209
  • [7] Inverse radiotherapy planning for intensity-modulated photon fields
    K. Preiser
    Th. Bortfeld
    K. Hartwig
    W. Schlegel
    J. Stein
    [J]. Der Radiologe, 1998, 38 : 228 - 234
  • [8] Inverse radiotherapy planning for intensity-modulated photon fields
    Preiser, K
    Bortfeld, T
    Hartwig, K
    Schlegel, W
    Stein, J
    [J]. RADIOLOGE, 1998, 38 (03): : 228 - 234
  • [9] A gradient inverse planning algorithm with dose-volume constraints
    Spirou, SV
    Chui, CS
    [J]. MEDICAL PHYSICS, 1998, 25 (03) : 321 - 333
  • [10] Comparison of intensity-modulated proton therapy and intensity-modulated photon therapy in treatment of nasopharyngeal carcinoma
    Taheri-Kadkhoda, Z.
    Nill, S.
    Wilkens, J.
    Oelfke, U.
    Bjoerk-Eriksson, T.
    Huber, P.
    Munter, M. W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 82 : S52 - S53