Mixed integer programming with dose-volume constraints in intensity-modulated proton therapy

被引:9
|
作者
Zhang, Pengfei [1 ]
Fan, Neng [2 ]
Shan, Jie [3 ]
Schild, Steven E. [1 ]
Bues, Martin [1 ]
Liu, Wei [1 ]
机构
[1] Mayo Clin, Dept Radiat Oncol, Scottsdale, AZ USA
[2] Univ Arizona, Dept Syst & Ind Engn, Tucson, AZ USA
[3] Arizona State Univ, Dept Biomed Informat, Phoenix, AZ USA
来源
关键词
dose-volume constraints; intensity-modulated proton therapy; mixed-integer programming; RADIATION-THERAPY; OPTIMIZATION; ALGORITHMS;
D O I
10.1002/acm2.12130
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In treatment planning for intensity-modulated proton therapy (IMPT), we aim to deliver the prescribed dose to the target yet minimize the dose to adjacent healthy tissue. Mixed-integer programming (MIP) has been applied in radiation therapy to generate treatment plans. However, MIP has not been used effectively for IMPT treatment planning with dose-volume constraints. In this study, we incorporated dose-volume constraints in an MIP model to generate treatment plans for IMPT. Methods: We created a new MIP model for IMPT with dose volume constraints. Two groups of IMPT treatment plans were generated for each of three patients by using MIP models for a total of six plans: one plan was derived with the Limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) method while the other plan was derived with our MIP model with dose-volume constraints. We then compared these two plans by dose-volume histogram (DVH) indices to evaluate the performance of the new MIP model with dose-volume constraints. In addition, we developed a model to more efficiently find the best balance between tumor coverage and normal tissue protection. Results: The MIP model with dose-volume constraints generates IMPT treatment plans with comparable target dose coverage, target dose homogeneity, and the maximum dose to organs at risk (OARs) compared to treatment plans from the conventional quadratic programming method without any tedious trial-and-error process. Some notable reduction in the mean doses of OARs is observed. Conclusions: The treatment plans from our MIP model with dose-volume constraints can meetall dose-volume constraints for OARs and targets without any tedious trial-and-error process. This model has the potential to automatically generate IMPT plans with consistent plan quality among different treatment planners and across institutions and better protection for important parallel OARs in an effective way.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [1] Dose-volume comparison of proton therapy and intensity-modulated radiotherapy for prostate cancer
    Vargas, Carlos
    Fryer, Amber
    Mahajan, Chaitali
    Indelicato, Daniel
    Horne, David
    Chellini, Angela
    Mckenzie, Craig
    Lawlor, Paula
    Henderson, Randal
    Li, Zuofeng
    Lin, Liyong
    Olivier, Kenneth
    Keole, Sameer
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (03): : 744 - 751
  • [2] Sparsity constrained split feasibility for dose-volume constraints in inverse planning of intensity-modulated photon or proton therapy
    Penfold, Scott
    Zalas, Rafal
    Casiraghi, Margherita
    Brooke, Mark
    Censor, Yair
    Schulte, Reinhard
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09): : 3599 - 3618
  • [3] Dose-volume specification: New challenges with intensity-modulated radiation therapy
    Purdy, JA
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) : 199 - 209
  • [4] Dose-volume constrained optimization in intensity-modulated radiation therapy treatment planning
    Yoshihiro Tanaka
    Ken’ichi Fujimoto
    Tetsuya Yoshinaga
    [J]. Journal of Inequalities and Applications, 2015
  • [5] Dose-volume constrained optimization in intensity-modulated radiation therapy treatment planning
    Tanaka, Yoshihiro
    Fujimoto, Ken'ichi
    Yoshinaga, Tetsuya
    [J]. JOURNAL OF INEQUALITIES AND APPLICATIONS, 2015, : 1 - 13
  • [6] Dose-volume histogram evaluation scheme for beam orientations in intensity-modulated radiation therapy
    Azizi-Sultan, Ahmad-Saher
    [J]. COMPUTATIONAL & APPLIED MATHEMATICS, 2018, 37 (01): : 191 - 204
  • [7] Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming
    Yang, Ruijie
    Dai, Jianrong
    Yang, Yong
    Hu, Yimin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (15): : 3653 - 3666
  • [8] Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming
    Yang, Ruijie
    Dai, Jianrong
    Yang, Yong
    Hu, Yimin
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1758 - +
  • [9] DOSE-VOLUME ANALYSIS OF WHOLE VENTRICULAR IRRADIATION BY PROTON BEAM COMPARING WITH INTENSITY-MODULATED RADIOTHERAPY AND STANDARD PHOTON THERAPY
    Fuji, Hiroshi
    Nakasu, Yoko
    Horiguchi, Satoshi
    Mitsuya, Koich
    Ishida, Yuji
    Murayama, Shigeyuki
    [J]. NEURO-ONCOLOGY, 2009, 11 (06) : 969 - 969
  • [10] Dose-volume comparison of proton therapy and intensity modulated radiation therapy in the treatment of prostate cancer
    Vargas, C. E.
    Fryer, A.
    Mahajan, C.
    Indelicato, D.
    Horne, D.
    Chellini, A.
    McKenzie, C.
    Lawlorl, P.
    Li, Z.
    Keole, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S338 - S339