Dose-volume histogram evaluation scheme for beam orientations in intensity-modulated radiation therapy

被引:0
|
作者
Azizi-Sultan, Ahmad-Saher [1 ]
机构
[1] Taibah Univ, Dept Math, Medina Munawarah, Saudi Arabia
来源
COMPUTATIONAL & APPLIED MATHEMATICS | 2018年 / 37卷 / 01期
关键词
Dose-volume histogram; Intensity-modulated radiation therapy; Beam orientations in IMRT; Beam selection in IMRT; OPTIMIZATION; IMRT; RADIOTHERAPY; ALGORITHM; SELECTION; MODEL;
D O I
10.1007/s40314-016-0341-9
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Beam orientations in intensity-modulated radiation therapy (IMRT) is an important, but difficult NP-hard optimization problem. A considerable part of this difficulty is due to the essential prerequisite of defining, appropriately, counter-intuitive criteria for a mathematical plan evaluation that coincides with the clinical judgment of the considered plan. Moreover, the quality of beam directions depends heavily on their intensities. Usually a stochastic selector is utilized for optimizing beam orientations, and the intensities are thus calculated many thousands of times, each time for a different selection of beam directions, resulting in excessive time complexity. Therefore, selecting an appropriate set of beam directions in IMRT is still a time-consuming manual trial-and-error search procedure that depends on intuition and empirical knowledge. To overcome these difficulties, this work utilizes the concept of dose-volume histogram (DVH), which is one of the main recognized quantitative measurement tools used for plan judgment, and presents a DVH evaluation scheme that parallelizes plan evaluation with clinical plan judgment. This scheme is then utilized to optimize the intensities of each individual beam, enabling it to be represented by its DVHs, produced for the different irradiated volumes. Finally, an evolutionary algorithm is employed to search for the best combination of those DVHs reflecting the clinical optimal. The presented methods have been applied to three real clinical examples. In comparison to the standard equally spaced beam plans, improvements were reported in all three cases. In comparison with the greedy algorithm, improvements were reported in those examples requiring more than five beam directions.
引用
收藏
页码:191 / 204
页数:14
相关论文
共 50 条
  • [1] Dose–volume histogram evaluation scheme for beam orientations in intensity-modulated radiation therapy
    Ahmad-Saher Azizi-Sultan
    Computational and Applied Mathematics, 2018, 37 : 191 - 204
  • [2] Dose-volume specification: New challenges with intensity-modulated radiation therapy
    Purdy, JA
    SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) : 199 - 209
  • [3] Dose-volume constrained optimization in intensity-modulated radiation therapy treatment planning
    Yoshihiro Tanaka
    Ken’ichi Fujimoto
    Tetsuya Yoshinaga
    Journal of Inequalities and Applications, 2015
  • [4] Dose-volume constrained optimization in intensity-modulated radiation therapy treatment planning
    Tanaka, Yoshihiro
    Fujimoto, Ken'ichi
    Yoshinaga, Tetsuya
    JOURNAL OF INEQUALITIES AND APPLICATIONS, 2015, : 1 - 13
  • [5] Optimal selection of beam orientations in intensity-modulated radiation therapy
    Wen, Ue-Pyng
    Yu, Ru-Siou
    Tsui, Che-Wei
    JOURNAL OF INDUSTRIAL AND PRODUCTION ENGINEERING, 2011, 28 (04) : 316 - 326
  • [6] Mixed integer programming with dose-volume constraints in intensity-modulated proton therapy
    Zhang, Pengfei
    Fan, Neng
    Shan, Jie
    Schild, Steven E.
    Bues, Martin
    Liu, Wei
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 29 - 35
  • [7] Dose-volume comparison of proton therapy and intensity-modulated radiotherapy for prostate cancer
    Vargas, Carlos
    Fryer, Amber
    Mahajan, Chaitali
    Indelicato, Daniel
    Horne, David
    Chellini, Angela
    Mckenzie, Craig
    Lawlor, Paula
    Henderson, Randal
    Li, Zuofeng
    Lin, Liyong
    Olivier, Kenneth
    Keole, Sameer
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (03): : 744 - 751
  • [8] LATE TOXICITY AFTER INTENSITY-MODULATED RADIATION THERAPY FOR LOCALIZED PROSTATE CANCER: AN EXPLORATION OF DOSE-VOLUME HISTOGRAM PARAMETERS TO LIMIT GENITOURINARY AND GASTROINTESTINAL TOXICITY
    Pederson, Aaron W.
    Fricano, Janine
    Correa, David
    Pelizzari, Charles A.
    Liauw, Stanley L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (01): : 235 - 241
  • [9] Evaluation of bladder dose in intensity-modulated radiation therapy of the prostate
    Higgins, P. D.
    Weaver, R.
    Dusenbery, K. E.
    MEDICAL DOSIMETRY, 2006, 31 (03) : 197 - 200
  • [10] Correlation of the Incidence of Hypothyroidism and the Dose-Volume Histogram in Head and Neck Cancer Patients Treated With Intensity Modulated Radiation Therapy
    Shimizu, A.
    Takehana, K.
    Makita, C.
    Tomita, N.
    Tachibana, H.
    Kodaira, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S719 - S719