Effect of Carbon and Steel Fibers on the Strength Properties and Electrical Conductivity of Fiber-Reinforced Cement Mortar

被引:5
|
作者
Jun, Hyung-Min [1 ]
Seo, Dong-Ju [1 ]
Lim, Doo-Yeol [1 ]
Park, Jong-Gun [2 ]
Heo, Gwang-Hee [3 ]
机构
[1] Konyang Univ, Sch Disaster & Safety Engn, 121 Daehak ro, Nonsan 32992, South Korea
[2] Konyang Univ, Publ Safety Res Ctr PSRC, 121 Daehak ro, Nonsan 32992, South Korea
[3] Konyang Univ, Dept Int Civil & Plant Engn, 121 Daehak ro, Nonsan 32992, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 06期
基金
新加坡国家研究基金会;
关键词
carbon fiber; steel fiber; mechanical properties; electrical conductivity; percolation threshold; POLYPROPYLENE-FIBER; MECHANICAL-PROPERTIES; CONCRETE; BEHAVIOR; PERFORMANCE; COMPOSITES; PVA; PERCOLATION; PASTE;
D O I
10.3390/app13063522
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cement-based composites are generally non-conductors with high electrical resistivity, but they can be used as conductors by incorporating conductive materials. Recently, research has been actively conducted to develop high-conductive fiber-reinforced cement mortar (FRCM) due to increased interest in multifunctional cement mortar required by the market today. Thus, the present paper investigated the effect of the developed conductive FRCM containing carbon and steel fibers on the fresh and mechanical properties as well as electrical conductivity. The performance of conductivity FRCM was studied based on flow, unit weight, air content, three-point flexural, compression, and electrical resistance tests. In addition, their performance was also compared and reviewed with plain mortar (PM). Furthermore, the surface shape and element components of the developed conductive FRCM fracture surface were analyzed using a scanning electron microscopy (SEM) and an energy dispersive X-ray spectrometer (EDS). The results showed that the addition of steel fibers slightly decreased the relative flow value, whereas the incorporation of carbon fibers is very disadvantageous in terms of fluidity due to the fiber ball phenomenon. The unit weight of mixture containing carbon fibers was somewhat decreased, whereas the changes in the amount of air contents were relatively insignificant regardless of the fiber volume fractions. The flexural strength of conductive carbon fiber-reinforced cement mortar (CFRCM) and steel fiber-reinforced cement mortar (SFRCM) was significantly improved compared to that of PM. The compressive strength of CFRCM decreased significantly as the volume fraction of carbon fibers increased. Overall, even if the steel fibers were added up to 1.25%, the effect of improving the electrical conductivity of SFRCM was insignificant. In the case of the CFRCM used in this study, it was found that the percolation threshold existed between 0.3% and 0.4% fibers, and it was thus thought that the optimum dosage of carbon fiber should be secured by at least more than 0.4% in terms of electrical conductivity. Therefore, the most important factor for the electrical conductivity effect was found to be carbon fiber, whereas the effect of steel fiber was insignificant.
引用
下载
收藏
页数:20
相关论文
共 50 条
  • [41] Effect of carbon fibers and graphite particles on mechanical properties and electrical conductivity of cement composite
    Zhao, Yunpeng
    Zhang, Jiaming
    Qiang, Sheng
    Lu, Hao
    Li, Jiajie
    JOURNAL OF BUILDING ENGINEERING, 2024, 94
  • [42] Averaging the electrical properties of fiber-reinforced metal composites with hollow fibers
    Filshtinskii, LA
    Bardzokas, D
    MECHANICS OF COMPOSITE MATERIALS, 1997, 33 (03) : 269 - 274
  • [43] Study of aramid and carbon fibers on the tensile properties of early strength cement mortar
    Nie, Liangxue
    Xu, Jinyu
    Luo, Xin
    Chen, Haowen
    Chang, Sen
    Wang, Tengjiao
    Liu, Gaojie
    2019 3RD INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2019), 2019, 267
  • [44] Averaging the electrical properties of fiber-reinforced metal composites with hollow fibers
    L. A. Fil'shtinskii
    D. Bardzokas
    Mechanics of Composite Materials, 1997, 33 : 269 - 274
  • [45] Absorption and Strength Properties of Short Carbon Fiber Reinforced Mortar Composite
    Safiuddin, Md
    Abdel-Sayed, George
    Hearn, Nataliya
    BUILDINGS, 2021, 11 (07)
  • [46] Effect of sand addition on properties of fiber-reinforced cement composites
    Akkaya, Y
    Peled, A
    Picka, JD
    Shah, SP
    ACI MATERIALS JOURNAL, 2000, 97 (03) : 393 - 400
  • [47] Nonlinear conduction in carbon fiber reinforced cement mortar
    Xu, Jing
    Yao, Wu
    Wang, Ruiqing
    CEMENT & CONCRETE COMPOSITES, 2011, 33 (03): : 444 - 448
  • [48] Electric polarization in carbon fiber-reinforced cement
    Wen, SH
    Chung, DDL
    CEMENT AND CONCRETE RESEARCH, 2001, 31 (01) : 141 - 147
  • [49] Strength and ductility of concrete beams reinforced with carbon fiber-reinforced polymer plates and steel
    Duthinh, D
    Starnes, M
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2004, 8 (01) : 59 - 69
  • [50] Effect of chemical vapor deposition treatment of carbon fibers on the reflectivity of carbon fiber-reinforced cement-based composites
    Li, Ke-zhi
    Wang, Chuang
    Li, He-jun
    Li, Xin-tao
    Ouyang, Hai-bo
    Wei, Jian
    COMPOSITES SCIENCE AND TECHNOLOGY, 2008, 68 (05) : 1105 - 1114