Effect of Carbon and Steel Fibers on the Strength Properties and Electrical Conductivity of Fiber-Reinforced Cement Mortar

被引:5
|
作者
Jun, Hyung-Min [1 ]
Seo, Dong-Ju [1 ]
Lim, Doo-Yeol [1 ]
Park, Jong-Gun [2 ]
Heo, Gwang-Hee [3 ]
机构
[1] Konyang Univ, Sch Disaster & Safety Engn, 121 Daehak ro, Nonsan 32992, South Korea
[2] Konyang Univ, Publ Safety Res Ctr PSRC, 121 Daehak ro, Nonsan 32992, South Korea
[3] Konyang Univ, Dept Int Civil & Plant Engn, 121 Daehak ro, Nonsan 32992, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 06期
基金
新加坡国家研究基金会;
关键词
carbon fiber; steel fiber; mechanical properties; electrical conductivity; percolation threshold; POLYPROPYLENE-FIBER; MECHANICAL-PROPERTIES; CONCRETE; BEHAVIOR; PERFORMANCE; COMPOSITES; PVA; PERCOLATION; PASTE;
D O I
10.3390/app13063522
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cement-based composites are generally non-conductors with high electrical resistivity, but they can be used as conductors by incorporating conductive materials. Recently, research has been actively conducted to develop high-conductive fiber-reinforced cement mortar (FRCM) due to increased interest in multifunctional cement mortar required by the market today. Thus, the present paper investigated the effect of the developed conductive FRCM containing carbon and steel fibers on the fresh and mechanical properties as well as electrical conductivity. The performance of conductivity FRCM was studied based on flow, unit weight, air content, three-point flexural, compression, and electrical resistance tests. In addition, their performance was also compared and reviewed with plain mortar (PM). Furthermore, the surface shape and element components of the developed conductive FRCM fracture surface were analyzed using a scanning electron microscopy (SEM) and an energy dispersive X-ray spectrometer (EDS). The results showed that the addition of steel fibers slightly decreased the relative flow value, whereas the incorporation of carbon fibers is very disadvantageous in terms of fluidity due to the fiber ball phenomenon. The unit weight of mixture containing carbon fibers was somewhat decreased, whereas the changes in the amount of air contents were relatively insignificant regardless of the fiber volume fractions. The flexural strength of conductive carbon fiber-reinforced cement mortar (CFRCM) and steel fiber-reinforced cement mortar (SFRCM) was significantly improved compared to that of PM. The compressive strength of CFRCM decreased significantly as the volume fraction of carbon fibers increased. Overall, even if the steel fibers were added up to 1.25%, the effect of improving the electrical conductivity of SFRCM was insignificant. In the case of the CFRCM used in this study, it was found that the percolation threshold existed between 0.3% and 0.4% fibers, and it was thus thought that the optimum dosage of carbon fiber should be secured by at least more than 0.4% in terms of electrical conductivity. Therefore, the most important factor for the electrical conductivity effect was found to be carbon fiber, whereas the effect of steel fiber was insignificant.
引用
下载
收藏
页数:20
相关论文
共 50 条
  • [31] Dynamic properties of fiber reinforced cement mortar
    Tang, Zhi-Ping
    Xu, Song-Lin
    Hu, Xiao-Jun
    Liao, Xiang-Li
    Cai, Jian
    Journal of Beijing Institute of Technology (English Edition), 2004, 13 (03): : 313 - 316
  • [32] PROPERTIES OF WASTE FIBER REINFORCED CEMENT MORTAR
    Al-Shathr, Basil
    Abdulhameed, Haider
    Mahdi, Mohammed
    Indian Concrete Journal, 2021, 95 (12): : 45 - 51
  • [33] Electrical Current Map and Bulk Conductivity of Carbon Fiber-Reinforced Nanocomposites
    Guadagno, Liberata
    Vertuccio, Luigi
    Naddeo, Carlo
    Raimondo, Marialuigia
    Barra, Giuseppina
    De Nicola, Felice
    Volponi, Ruggero
    Lamberti, Patrizia
    Spinelli, Giovanni
    Tucci, Vincenzo
    POLYMERS, 2019, 11 (11)
  • [34] Effect of moisture on piezoresistivity of carbon fiber-reinforced cement paste
    Wen, Sihai
    Chung, D. D. L.
    ACI MATERIALS JOURNAL, 2008, 105 (03) : 274 - 280
  • [35] STUDY OF THE INTERFACE STRENGTH IN STEEL FIBER-REINFORCED CEMENT-BASED COMPOSITES
    WEI, S
    MANDEL, JA
    SAID, S
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1986, 83 (04): : 597 - 605
  • [36] Effect of moisture on piezoresistivity of carbon fiber-reinforced cement paste
    Department of Mechanical and Aerospace Engineering, University at Buffalo, State University of New York, Buffalo, NY, United States
    不详
    不详
    ACI Mater J, 2008, 3 (274-280):
  • [37] Mechanical properties of cement mortar reinforced with aligned carbon fibers by magnetic field
    Wang Y.
    Xu J.
    Jiang L.
    Yin T.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2019, 36 (11): : 2726 - 2733
  • [38] FUTURE-DEVELOPMENTS IN FIBER-REINFORCED CEMENT, MORTAR AND CONCRETE
    WELLS, RA
    COMPOSITES, 1982, 13 (02): : 169 - 172
  • [39] Effect of carbon fiber grade on the electrical behavior of carbon fiber reinforced cement
    Wen, SH
    Chung, DDL
    CARBON, 2001, 39 (03) : 369 - 373
  • [40] Strength properties of fiber reinforced concrete including steel fibers
    Adlparvar, Mohammad Reza
    Esmaeili, Morteza
    Parsa, Mohammad Hossein Taghavi
    WORLD JOURNAL OF ENGINEERING, 2024, 21 (01) : 194 - 202