Effect of Carbon and Steel Fibers on the Strength Properties and Electrical Conductivity of Fiber-Reinforced Cement Mortar

被引:5
|
作者
Jun, Hyung-Min [1 ]
Seo, Dong-Ju [1 ]
Lim, Doo-Yeol [1 ]
Park, Jong-Gun [2 ]
Heo, Gwang-Hee [3 ]
机构
[1] Konyang Univ, Sch Disaster & Safety Engn, 121 Daehak ro, Nonsan 32992, South Korea
[2] Konyang Univ, Publ Safety Res Ctr PSRC, 121 Daehak ro, Nonsan 32992, South Korea
[3] Konyang Univ, Dept Int Civil & Plant Engn, 121 Daehak ro, Nonsan 32992, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 06期
基金
新加坡国家研究基金会;
关键词
carbon fiber; steel fiber; mechanical properties; electrical conductivity; percolation threshold; POLYPROPYLENE-FIBER; MECHANICAL-PROPERTIES; CONCRETE; BEHAVIOR; PERFORMANCE; COMPOSITES; PVA; PERCOLATION; PASTE;
D O I
10.3390/app13063522
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cement-based composites are generally non-conductors with high electrical resistivity, but they can be used as conductors by incorporating conductive materials. Recently, research has been actively conducted to develop high-conductive fiber-reinforced cement mortar (FRCM) due to increased interest in multifunctional cement mortar required by the market today. Thus, the present paper investigated the effect of the developed conductive FRCM containing carbon and steel fibers on the fresh and mechanical properties as well as electrical conductivity. The performance of conductivity FRCM was studied based on flow, unit weight, air content, three-point flexural, compression, and electrical resistance tests. In addition, their performance was also compared and reviewed with plain mortar (PM). Furthermore, the surface shape and element components of the developed conductive FRCM fracture surface were analyzed using a scanning electron microscopy (SEM) and an energy dispersive X-ray spectrometer (EDS). The results showed that the addition of steel fibers slightly decreased the relative flow value, whereas the incorporation of carbon fibers is very disadvantageous in terms of fluidity due to the fiber ball phenomenon. The unit weight of mixture containing carbon fibers was somewhat decreased, whereas the changes in the amount of air contents were relatively insignificant regardless of the fiber volume fractions. The flexural strength of conductive carbon fiber-reinforced cement mortar (CFRCM) and steel fiber-reinforced cement mortar (SFRCM) was significantly improved compared to that of PM. The compressive strength of CFRCM decreased significantly as the volume fraction of carbon fibers increased. Overall, even if the steel fibers were added up to 1.25%, the effect of improving the electrical conductivity of SFRCM was insignificant. In the case of the CFRCM used in this study, it was found that the percolation threshold existed between 0.3% and 0.4% fibers, and it was thus thought that the optimum dosage of carbon fiber should be secured by at least more than 0.4% in terms of electrical conductivity. Therefore, the most important factor for the electrical conductivity effect was found to be carbon fiber, whereas the effect of steel fiber was insignificant.
引用
下载
收藏
页数:20
相关论文
共 50 条
  • [21] Effect of carbon fiber dispersion on the mechanical properties of carbon fiber-reinforced cement-based composites
    Wang, Chuang
    Li, Ke-Zhi
    Li, He-Jun
    Jiao, Geng-Sheng
    Lu, Jinhua
    Hou, Dang-She
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2008, 487 (1-2): : 52 - 57
  • [22] Effect of Multi-Walled Carbon Nanotubes on Strength and Electrical Properties of Cement Mortar
    Cerro-Prada, Elena
    Pacheco-Torres, Rosalia
    Varela, Fernando
    MATERIALS, 2021, 14 (01) : 1 - 13
  • [23] Carbon fiber-reinforced cement as a thermistor
    Wen, SH
    Chung, DDL
    CEMENT AND CONCRETE RESEARCH, 1999, 29 (06) : 961 - 965
  • [24] Carbon fiber-reinforced cement as a thermistor
    Compos. Mat. Research Laboratory, State Univ. of New York at Buffalo, Buffalo, NY 14260-4400, United States
    Cem Concr Res, 6 (961-965):
  • [25] Biaxial compression in carbon fiber-reinforced mortar sensed by electrical resistance measurement
    Wu, B
    Huang, XJ
    Lu, JZ
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 893 - 898
  • [26] Electro-thermal properties of carbon fiber reinforced cement mortar
    Hai, Ran
    Yang, Jiu-Jun
    Zhang, Hai-Tao
    Wu, Ke-Ru
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2006, 9 (05): : 593 - 597
  • [27] Properties of electrical resistivity of fiber-reinforced cement composites with multi-walled carbon nanotubes
    Luo, Jian-Lin
    Duan, Zhong-Dong
    Zhao, Tie-Jun
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (08): : 1237 - 1241
  • [28] Electrical conductivity characterization and variation of carbon fiber reinforced cement composite
    Xiufeng Wang
    Yonglan Wang
    Zhihao Jin
    Journal of Materials Science, 2002, 37 : 223 - 227
  • [29] Electrical conductivity characterization and variation of carbon fiber reinforced cement composite
    Wang, XF
    Wang, YL
    Jin, ZH
    JOURNAL OF MATERIALS SCIENCE, 2002, 37 (01) : 223 - 227
  • [30] Dynamic Properties of Fiber Reinforced Cement Mortar
    唐志平
    徐松林
    胡晓军
    廖香丽
    蔡建
    Journal of Beijing Institute of Technology, 2004, (03) : 313 - 316