An inversion decomposition method for better energy resolution of NaI(Tl) scintillation detectors based on a Gaussian response matrix

被引:1
|
作者
Jian-Feng He [1 ,2 ]
Yao-Zong Yang [3 ]
Jin-Hui Qu [1 ]
Qi-Fan Wu [2 ]
Hai-Ling Xiao [1 ]
Cong-Cong Yu [4 ]
机构
[1] Fundamental Science on Radioactive Geology and Exploration Technology Laboratory,East China Institute of Technology
[2] Department of Engineering Physics,Tsinghua University
[3] Jiujiang Power Supply Subsidiary Company of State Grid Jianxi Electronic Power Company
[4] Sichuan Integrative Medicine Hospital Sub-health Testing and Evaluation Laboratory
基金
中国国家自然科学基金;
关键词
Na I(Tl) scintillation detector; Gamma-ray energy spectrum; Gaussian response matrix; Inversion decomposition;
D O I
暂无
中图分类号
TL812 [闪烁探测技术和仪器];
学科分类号
082704 ;
摘要
NaI(T1) scintillation detectors have been widely applied for gamma-ray spectrum measurements owing to advantages such as high detection efficiency and low price.However,the mitigation of the limited energy resolution of these detectors,which detracts from an accurate analysis of the instrument spectra obtained,remains a crucial need.Based on the physical properties and spectrum formation processes of NaI(T1) scintillation detectors,the detector response to gamma photons with different energies is represented by photopeaks that are approximately Gaussian in shape with unique full-width-at-half-maximum(FWHM) values.The FWHM is established as a detector parameter based on resolution calibrations and is used in the construction of a general Gaussian response matrix,which is employed for the inverse decomposition of gamma spectra obtained from the detector.The Gold and Boosted Gold iterative algorithms are employed to accelerate the decomposition of the measured spectrum.Tests of the inverse decomposition method on multiple simulated overlapping peaks and on experimentally obtained U and Th radionuclide series spectra verify the practicability of the method,particularly in the low-energy region of the spectrum,providing for the accurate qualitative and quantitative analysis of radionuclides.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 48 条
  • [31] EXPERIMENTAL DETERMINATION OF ABSOLUTE EFFICIENCY AND ENERGY RESOLUTION FOR NaI(Tl) AND GERMANIUM GAMMA RAY DETECTORS AT ENERGIES FROM 2. 6 TO 16. 1 Mev.
    Cecil, F.E.
    Wilkinson III, F.J.
    Ristinen, R.A.
    Rieppo, Risto
    Nuclear instruments and methods in physics research, 1985, A234 (03): : 479 - 482
  • [32] Experimental response function of a 3 in x 3 in NaI(Tl) detector by inverse matrix method and effective atomic number of composite materials by gamma backscattering technique
    Kiran, K. U.
    Ravindraswami, K.
    Eshwarappa, K. M.
    Somashekarappa, H. M.
    APPLIED RADIATION AND ISOTOPES, 2016, 111 : 56 - 65
  • [33] Improved energy resolution for scintillator based gamma-ray detectors obtained using a CsI(Tl)/Si-PIN detector
    Patt, BE
    Iwanczyk, JS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (10): : 3926 - 3927
  • [34] Low Dose Rate X-Ray Radiation Fields Implementation for Study of Energy Response of the Dosimeters Based on Scintillation Detectors
    Novichenko, A. V.
    Lukashevich, R. V.
    Senkovsky, K. G.
    DEVICES AND METHODS OF MEASUREMENTS, 2019, 10 (02): : 128 - 137
  • [35] Area Restoration of Channel Impulse Response with Time Decomposition based Super-Resolution Method
    Wang S.
    Gao S.
    Yang W.
    Loh T.H.
    Yang Y.
    Qin F.
    IEEE Transactions on Wireless Communications, 2024, 23 (08) : 1 - 1
  • [36] EXPERIMENTAL RESPONSE FUNCTIONS SPANNING THE GAMMA-RAY ENERGY-RANGE OF 123.6 KEV TO 11.67 MEV AND RESPONSE MATRIX GENERATION FOR BISMUTH-GERMANATE SCINTILLATION DETECTORS
    KIZIAH, RR
    LOWELL, JR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (01): : 129 - 142
  • [37] A new and better method of MVDR (minimum variance distortionless response) mode filtering based on mode decomposition
    Yi, Feng
    Sun, Chao
    Xiang, Longfeng
    Liu, Zongwei
    Xibei Gongye Daxue Xuebao/Journal of Northwestern Polytechnical University, 2012, 30 (01): : 112 - 116
  • [38] A Post-Processed Multi-Material Decomposition Method based on Dynamic Dual-energy Detectors
    Yao, Yidi
    Li, Liang
    Chen, Zhiqiang
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [39] Hydrocarbon identification using the AVO response correction method based on high-resolution complex spectral decomposition
    Tan, Huihuang
    Zhou, Donghong
    Zhang, Shengqiang
    Zhang, Zhijun
    Duan, Xinyi
    Gao, Wei
    INTERPRETATION-A JOURNAL OF SUBSURFACE CHARACTERIZATION, 2020, 8 (01): : SA49 - SA61
  • [40] A Cost-Effective High-Resolution Modular Pixelated Clinical SPECT Detector Based on Small NaI (Tl) Pixels with Medium-Size Single-Anode PMTs, Utilizing Spatial Modulation of Scintillation Light Output
    Rozler, Mike
    Chang, Wei
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3510 - 3514