An inversion decomposition method for better energy resolution of NaI(Tl) scintillation detectors based on a Gaussian response matrix

被引:1
|
作者
Jian-Feng He [1 ,2 ]
Yao-Zong Yang [3 ]
Jin-Hui Qu [1 ]
Qi-Fan Wu [2 ]
Hai-Ling Xiao [1 ]
Cong-Cong Yu [4 ]
机构
[1] Fundamental Science on Radioactive Geology and Exploration Technology Laboratory,East China Institute of Technology
[2] Department of Engineering Physics,Tsinghua University
[3] Jiujiang Power Supply Subsidiary Company of State Grid Jianxi Electronic Power Company
[4] Sichuan Integrative Medicine Hospital Sub-health Testing and Evaluation Laboratory
基金
中国国家自然科学基金;
关键词
Na I(Tl) scintillation detector; Gamma-ray energy spectrum; Gaussian response matrix; Inversion decomposition;
D O I
暂无
中图分类号
TL812 [闪烁探测技术和仪器];
学科分类号
082704 ;
摘要
NaI(T1) scintillation detectors have been widely applied for gamma-ray spectrum measurements owing to advantages such as high detection efficiency and low price.However,the mitigation of the limited energy resolution of these detectors,which detracts from an accurate analysis of the instrument spectra obtained,remains a crucial need.Based on the physical properties and spectrum formation processes of NaI(T1) scintillation detectors,the detector response to gamma photons with different energies is represented by photopeaks that are approximately Gaussian in shape with unique full-width-at-half-maximum(FWHM) values.The FWHM is established as a detector parameter based on resolution calibrations and is used in the construction of a general Gaussian response matrix,which is employed for the inverse decomposition of gamma spectra obtained from the detector.The Gold and Boosted Gold iterative algorithms are employed to accelerate the decomposition of the measured spectrum.Tests of the inverse decomposition method on multiple simulated overlapping peaks and on experimentally obtained U and Th radionuclide series spectra verify the practicability of the method,particularly in the low-energy region of the spectrum,providing for the accurate qualitative and quantitative analysis of radionuclides.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 48 条
  • [21] A HYBRID ANALYTICAL-NUMERICAL METHOD FOR EFFICIENCY CALCULATIONS OF SPHERICAL SCINTILLATION NaI(Tl) DETECTORS AND ARBITRARILY LOCATED POINT SOURCES
    Noureldine, Salam E.
    Badawi, Mohamed S.
    Abbas, Mahmoud I.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2017, 32 (02): : 140 - 147
  • [22] Semi-empirical gamma-ray response function of BGO, NaI(Tl) and LaBr3(Ce) scintillation detectors
    Grozdanov, D. N.
    Fedorov, N. A.
    Kopatch, Yu N.
    Ruskov, I. N.
    Skoy, V. R.
    Tretyakova, T. Yu
    Dabylova, S. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1014
  • [23] Energy-based scatter correction for 3-D PET scanners using NaI(Tl) detectors
    Adam, LE
    Karp, JS
    Freifelder, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 513 - 521
  • [24] Energy response of the TL detectors based on YAlO3:Mn crystals
    Zhydachevskii, Ya
    Morgun, A.
    Dubinski, S.
    Yu, Yan
    Glowacki, M.
    Ubizskii, S.
    Chumak, V.
    Berkowski, M.
    Suchocki, A.
    RADIATION MEASUREMENTS, 2016, 90 : 262 - 264
  • [25] STATISTICAL APPROACH TO CHOICE OF CHANNEL-WIDTH IN GAMMA-RAY SPECTROMETRY .2. USE OF A SEMIEMPIRICAL RELATION BETWEEN RESOLUTION AND GAMMA-RAY ENERGY FOR NAI(TL) SCINTILLATION DETECTORS
    FURLER, R
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1975, 24 (02): : 411 - 421
  • [26] MATRIX-METHOD TO CORRECT FOR NONLINEAR ENERGY RESPONSE OF NAI(TI) SPECTROMETER SYSTEMS
    WAGGENER, RG
    ROGERS, LF
    ZANCA, P
    HEALTH PHYSICS, 1972, 22 (03): : 292 - +
  • [27] NTRU Inverse Polynomial Algorithm Based on the LU Decomposition Method of Matrix Inversion
    Gaithuru, Juliet N.
    Salleh, Mazleena
    Mohamad, Ismail
    2017 IEEE CONFERENCE ON APPLICATION, INFORMATION AND NETWORK SECURITY (AINS), 2017, : 1 - 6
  • [28] Performance evaluation of compact detectors based on new pixellated NaI(Tl) crystal arrays for high-resolution small animal imaging.
    Qi, YJ
    Tsui, BM
    Frey, EC
    Yoder, B
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 59P - 59P
  • [29] A novel vegetation height inversion method based on polarimetric interferometric covariance matrix decomposition
    Song, Guiping
    Wang, Changcheng
    Fu, Haiqiang
    Xie, Qinghua
    Cehui Xuebao/Acta Geodaetica et Cartographica Sinica, 2014, 43 (06): : 613 - 619
  • [30] EXPERIMENTAL STUDY OF THE INFLUENCE OF NON-PROPORTIONAL RESPONSE OF NAI(T1) SCINTILLATION CRYSTALS UPON THE ENERGY RESOLUTION FOR GAMMA-RAYS
    THIEBERGER, P
    BONACALZA, ECO
    RYDE, H
    NUCLEAR INSTRUMENTS & METHODS, 1961, 14 (02): : 225 - 230