Measurement of central corneal thickness and precorneal tear film thickness of rabbits using the Scheimpflug system

被引:0
|
作者
Jing Dong [1 ]
Qiang Wu [2 ]
Xiao-Gang Wang [2 ]
机构
[1] Department of Ophthalmology,the First Hospital of Shanxi Medical University
[2] Department of Ophthalmology,the Sixth People's Hospital Affiliated to Shanghai Jiaotong University
关键词
tear film; Scheimpflug; rabbits; central corneal thickness; fluorescein;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM:To measure central corneal thickness(CCT) and pre-corneal tear film thickness using the Galilei dual Scheimpflug analyzer(GSA) in New Zealand White rabbits.METHODS:Ten normal New Zealand White rabbits(20 eyes) were included in this study.With the assistance of 0.1% fluorescein,the pre-corneal tear film can be well visualized.Both eyes of each rabbit were scanned once with the GSA pre- and post-instillation of 1μL 0.1% fluorescein.The difference between the two measurements of CCT(4-mm diameter) was recorded as the pachymetric values of the central tear film.RESULTS:The CCT of pre- and post-instillation was 388.8±9.5μm and 407.0±10.5μm,respectively.After a paired t-test analysis,the central pre-corneal tear film thickness of 4mm diameter was 18.2±5.31μm with a 95% confidence interval of(15.7,20.6)μm(P<0.001).CONCLUSION:GSA can be used to measure CCT and analyze central tear film thickness of rabbits with the help of fluorescein.
引用
收藏
页码:584 / 587
页数:4
相关论文
共 50 条
  • [21] Effect of 2% fluorescein on Scheimpflug central corneal thickness measurements
    Briggs, Stella
    Bin Moammar, Marwa
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (02) : 239 - 242
  • [22] Effect of 2% fluorescein on Scheimpflug central corneal thickness measurements
    Stella Briggs
    Marwa Bin Moammar
    [J]. International Journal of Ophthalmology, 2016, 9 (02) : 239 - 242
  • [23] IOP measurement and central corneal thickness
    Stodtmeister, R
    Kron, M
    Gaus, W
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (01) : 120 - 121
  • [24] IOP Measurement and Central Corneal Thickness
    Stodtmeister, Richard
    [J]. OPHTHALMOLOGY, 2012, 119 (12) : 2647 - 2648
  • [25] Central corneal thickness and anterior chamber depth measurement by Sirius (R) Scheimpflug tomography and ultrasound
    Jorge, J.
    Rosado, J. L.
    Diaz-Rey, J. A.
    Gonzalez-Meijome, J. M.
    [J]. CLINICAL OPHTHALMOLOGY, 2013, 7 : 417 - 422
  • [26] Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    Barkana, Y
    Gerber, Y
    Elbaz, U
    Schwartz, S
    Ken-Dror, G
    Avni, I
    Zadok, D
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09): : 1729 - 1735
  • [27] Impact of corneal refractive surgery on the precorneal tear film
    Sharma, Bhavana
    Soni, Deepak
    Saxena, Harsha
    Stevenson, Louis J.
    Karkhur, Samendra
    Takkar, Brijesh
    Vajpayee, Rasik B.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) : 2804 - 2812
  • [28] REPEATABILITY OF CENTRAL CORNEAL THICKNESS MEASUREMENT WITH THE PENTACAM HR SYSTEM
    Alonso, Ruiz
    Ambrosio, Renato
    Ventura, Marcelo Palis
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [29] Evaluation of Central Corneal Thickness Using Corneal Dynamic Scheimpflug Analyzer Corvis ST and Comparison with Pentacam Rotating Scheimpflug System and Ultrasound Pachymetry in Normal Eyes
    Yu, Ayong
    Zhao, Weiqi
    Savini, Giacomo
    Huang, Zixu
    Bao, Fangjun
    Lu, Weicong
    Wang, Qinmei
    Huang, Jinhai
    [J]. JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [30] Repeatability of central corneal thickness measurement with the Pentacam HR system
    Alonso, Ruiz Simonato
    Fontes, Bruno Machado
    Ventura, Marcelo Palis
    Ambrosio, Renato, Jr.
    [J]. REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (01) : 14 - 17