Polyaniline-graphite composite film glucose oxidase electrode

被引:0
|
作者
周海晖
陈宏
陈金华
旷亚非
机构
[1] Changsha 410082 ChinaState Key Laboratory of Chemo/Biosensing and Chemometrics Hunan UniversityChangsha 410082 China
[2] College of Chemistry and Chemical Engineering Hunan University
[3] College of Chemistry and Chemical Engineering Hunan University
基金
中国国家自然科学基金;
关键词
polyaniline; graphite; composite film; glucose oxidase; biosensor;
D O I
暂无
中图分类号
O646.54 [电极过程];
学科分类号
081704 ;
摘要
A novel polyaniline-graphite composite film glucose oxidase (PGCF GOD) electrode was developed. The PGCF was synthesized by cyclic voltammetry method in 0.5 mol/L H2SO4 solution containing 1 g/L graphite powder and 0.2 mol/L aniline. The PGCF GOD electrode was prepared by doping GOD into the composite film. The morphology of the PGCF and the response property of the PGCF GOD electrode were investigated by scanning electron microscopy and electrochemical measurement, respectively. The results show that the PGCF has a porous and netty structure and the PGCF GOD electrode has excellent response property such as high sensitivity and short response time. Influences of pH value, temperature, glucose concentration and potential on the response current of the electrode were also discussed. The sensor has a maximum steady-state current density of 357.17 μA/cm2 and an apparent Michaelis-Menten constant of 16.57 mmol/L. The maximum current response of the enzyme electrode occurs under the condition of pH 5.5, 0.8 V and 65 ℃.
引用
收藏
页码:653 / 657
页数:5
相关论文
共 50 条
  • [41] BENZOQUINONE-MEDIATED GLUCOSE GLUCOSE-OXIDASE REACTION AT PYROLYTIC-GRAPHITE ELECTRODE
    SURYA, A
    MURTHY, N
    ANITA
    ELECTROANALYSIS, 1993, 5 (03) : 265 - 268
  • [42] AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON ADSORBED GLUCOSE-OXIDASE ON PALLADIUM GOLD MODIFIED GRAPHITE
    JONSSON, G
    GORTON, L
    ANALYTICAL LETTERS, 1987, 20 (06) : 839 - 855
  • [43] Amperometric glucose sensing with polyaniline/poly(acrylic acid) composite film bearing glucose oxidase and catalase based on competitive oxygen consumption reactions
    Kuwahara, Takashi
    Ogawa, Kohei
    Sumita, Daiki
    Kondo, Mizuki
    Shimomura, Masato
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 811 : 62 - 67
  • [44] Polyaniline/polysulfone composite film electrode for simultaneous determination of hydroquinone and catechol
    Feng, Xiaojuan
    Shi, Yanlong
    Hu, Zhongai
    MATERIALS CHEMISTRY AND PHYSICS, 2011, 131 (1-2) : 72 - 76
  • [45] Reversible immobilization of glucose oxidase on polyaniline grafted polyacrylonitrile conductive composite membrane
    Bayramoglu, Gulay
    Metin, Ayseguel Ue
    Altintas, Begum
    Arica, M. Yakup
    BIORESOURCE TECHNOLOGY, 2010, 101 (18) : 6881 - 6887
  • [46] Photoeffects at a polyaniline film electrode
    Kilmartin, PA
    Wright, GA
    ELECTROCHIMICA ACTA, 1996, 41 (10) : 1677 - 1687
  • [47] An Amperometric Biosensor for Glucose Determination Prepared from Glucose Oxidase Immobilized in Polyaniline-Polyvinylsulfonate Film
    Arslan, Fatma
    Ustabas, Selvin
    Arslan, Halit
    SENSORS, 2011, 11 (08) : 8152 - 8163
  • [48] Polyaniline synthesis catalysed by glucose oxidase
    Kausaite, A.
    Ramanaviciene, A.
    Ramanavicius, A.
    POLYMER, 2009, 50 (08) : 1846 - 1851
  • [49] Amperometric glucose biosensor based on glucose oxidase encapsulated in carbon nanotube-titania-nafion composite film on platinized glassy carbon electrode
    Choi, Han Nim
    Han, Jee Hoon
    Park, Ji Ae
    Lee, Joong Min
    Lee, Won-Yong
    ELECTROANALYSIS, 2007, 19 (17) : 1757 - 1763
  • [50] An amperometric glucose biosensor based on glucose oxidase immobilized in electropolymerized poly(o-aminophenol) and carbon nanotubes composite film on a gold electrode
    Pan, DW
    Chen, JH
    Yao, SZ
    Tao, WY
    Nie, LH
    ANALYTICAL SCIENCES, 2005, 21 (04) : 367 - 371