An Amperometric Biosensor for Glucose Determination Prepared from Glucose Oxidase Immobilized in Polyaniline-Polyvinylsulfonate Film

被引:55
|
作者
Arslan, Fatma [1 ]
Ustabas, Selvin [2 ]
Arslan, Halit [1 ]
机构
[1] Gazi Univ, Dept Chem, Fac Sci, TR-06500 Ankara, Turkey
[2] Gazi Univ, Inst Sci, Dept Chem, TR-06500 Ankara, Turkey
关键词
glucose; biosensor; amperometry; polyaniline; polyvinylsulphonate; ELECTRODE;
D O I
10.3390/s110808152
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a novel amperometric glucose biosensor with immobilization of glucose oxidase on electrochemically polymerized polyaniline-polyvinylsulphonate (Pani-Pvs) films has been accomplished via the entrapment technique. Electropolymerization of aniline on the Pt surface of the Pt electrode was carried out at constant potential (0.75 V, vs. Ag/AgCl) using an electrochemical cell containing aniline and polyvinylsulphonate. Firstly, the optimum working conditions for preparing polyaniline-polyvinylsulfonate films were investigated. Determination of glucose was carried out by the oxidation of enzymatically produced H2O2 at 0.4 V vs. Ag/AgCl. The effects of pH and temperature were investigated and the optimum pH value was found to be 7.5. The storage stability and operational stability of the enzyme electrode were also studied. The results show that 75% of the response current was retained after 16 activity assays. The prepared glucose biosensor retained 80.6% of initial activity after 40 days when stored in 0.1 M phosphate buffer solution at 4 degrees C.
引用
收藏
页码:8152 / 8163
页数:12
相关论文
共 50 条
  • [1] An amperometric biosensor for glucose detection from glucose oxidase immobilized in polyaniline-polyvinylsulfonate-potassium ferricyanide film
    Arslan, Fatma
    Beskan, Umut
    [J]. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2014, 42 (04) : 284 - 288
  • [2] An amperometric biosensor for choline determination prepared from choline oxidase immobilized in polypyrrole-polyvinylsulfonate film
    Ozdemir, Merve
    Arslan, Fatma
    Arslan, Halit
    [J]. ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2012, 40 (04): : 280 - 284
  • [3] GLUCOSE BIOSENSOR USING GLUCOSE-OXIDASE IMMOBILIZED IN POLYANILINE
    PARENTE, AH
    MARQUES, ETA
    AZEVEDO, WM
    DINIZ, FB
    MELO, EHM
    FILHO, JLL
    [J]. APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1992, 37 (03) : 267 - 273
  • [4] An amperometric biosensor for xanthine determination prepared from xanthine oxidase immobilized in polypyrrole film
    Arslan, F
    Yasar, A
    Kiliç, E
    [J]. ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2006, 34 (01): : 113 - 128
  • [5] GLUCOSE-OXIDASE IMMOBILIZED IN POLYURETHANE MATRIX - A BIOSENSOR FOR AMPEROMETRIC ESTIMATION OF GLUCOSE
    ALVA, S
    PHADKE, RS
    GOVIL, G
    [J]. JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1993, 70 (4-5) : 403 - 408
  • [6] An amperometric biosensor for uric acid determination prepared from uricase immobilized in polyaniline-polypyrrole film
    Arslan, Fatma
    [J]. SENSORS, 2008, 8 (09) : 5492 - 5500
  • [7] Polyaniline glucose oxidase biosensor prepared with template process
    Pan, XH
    Kan, JQ
    Yuan, LM
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2004, 102 (02) : 325 - 330
  • [8] Construction of a glucose biosensor immobilized with glucose oxidase in the film of polypyrrole nanotubules
    Miao, YQ
    Qi, M
    Zhan, SZ
    He, NY
    Wang, J
    Yuan, CW
    [J]. ANALYTICAL LETTERS, 1999, 32 (07) : 1287 - 1299
  • [9] IMMOBILIZATION OF GLUCOSE OXIDASE IN SILICA SOL-GEL FILM FOR APPLICATION TO BIOSENSOR AND AMPEROMETRIC DETERMINATION OF GLUCOSE
    Demirkiran, Nizamettin
    Ekinci, Ergun
    Asilturk, Meltem
    [J]. JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2012, 57 (04) : 1336 - 1339
  • [10] Amperometric glucose determination by means of glucose oxidase immobilized on a cellulose acetate film: Dependence on the immobilization procedures
    Portaccio, Marianna
    Durante, Daniela
    Viggiano, Andrea
    Di Martino, Silvana
    De Luca, Paola
    Di Tuoro, Daniela
    Bencivenga, Umberto
    Rossi, Sergio
    Canciglia, Paolo
    De Luca, Bruno
    Mita, Datniano Gustavo
    [J]. ELECTROANALYSIS, 2007, 19 (17) : 1787 - 1793