Polyaniline-graphite composite film glucose oxidase electrode

被引:0
|
作者
周海晖
陈宏
陈金华
旷亚非
机构
[1] Changsha 410082 ChinaState Key Laboratory of Chemo/Biosensing and Chemometrics Hunan UniversityChangsha 410082 China
[2] College of Chemistry and Chemical Engineering Hunan University
[3] College of Chemistry and Chemical Engineering Hunan University
基金
中国国家自然科学基金;
关键词
polyaniline; graphite; composite film; glucose oxidase; biosensor;
D O I
暂无
中图分类号
O646.54 [电极过程];
学科分类号
081704 ;
摘要
A novel polyaniline-graphite composite film glucose oxidase (PGCF GOD) electrode was developed. The PGCF was synthesized by cyclic voltammetry method in 0.5 mol/L H2SO4 solution containing 1 g/L graphite powder and 0.2 mol/L aniline. The PGCF GOD electrode was prepared by doping GOD into the composite film. The morphology of the PGCF and the response property of the PGCF GOD electrode were investigated by scanning electron microscopy and electrochemical measurement, respectively. The results show that the PGCF has a porous and netty structure and the PGCF GOD electrode has excellent response property such as high sensitivity and short response time. Influences of pH value, temperature, glucose concentration and potential on the response current of the electrode were also discussed. The sensor has a maximum steady-state current density of 357.17 μA/cm2 and an apparent Michaelis-Menten constant of 16.57 mmol/L. The maximum current response of the enzyme electrode occurs under the condition of pH 5.5, 0.8 V and 65 ℃.
引用
收藏
页码:653 / 657
页数:5
相关论文
共 50 条
  • [21] Direct electrochemistry of glucose oxidase on the hydroxyapatite/Nafion composite film modified electrode and its application for glucose biosensing
    RongNa Ma
    Bin Wang
    Yan Liu
    Jing Li
    Qian Zhao
    GuoTao Wang
    WenLi Jia
    HuaiSheng Wang
    Science in China Series B: Chemistry, 2009, 52 : 2013 - 2019
  • [22] Glassy carbon electrode modified with glucose oxidase-graphene-nano-copper composite film for glucose sensing
    Huang, Ke-Jing
    Wang, Lan
    Li, Jing
    Gan, Tian
    Liu, Yan-Ming
    MEASUREMENT, 2013, 46 (01) : 378 - 383
  • [23] Direct electrochemistry of glucose oxidase on the hydroxyapatite/Nafion composite film modified electrode and its application for glucose biosensing
    Ma RongNa
    Wang Bin
    Liu Yan
    Li Jing
    Zhao Qian
    Wang GuoTao
    Jia WenLi
    Wang HuaiSheng
    SCIENCE IN CHINA SERIES B-CHEMISTRY, 2009, 52 (11): : 2013 - 2019
  • [24] Synthesis of exfoliated conductive polyaniline-graphite nanocomposites in supercritical CO2
    Akbarinezhad, E.
    Sabouri, M.
    JOURNAL OF SUPERCRITICAL FLUIDS, 2013, 75 : 81 - 87
  • [25] Polyaniline-graphite on cellulose substrate: a flexible, low-cost, use-and-throw sensor for glucose concentration detection
    Dipankar Das
    Jayanta Das
    Ajit Debnath
    Santanu Chakraborty
    Biswajit Saha
    Cellulose, 2023, 30 : 6423 - 6433
  • [26] Bienzymatic glucose biosensor based on graphite electrode modified with nanofibrous polyaniline
    Guo Xiao-Li
    Guo Min
    Wang Xin-Dong
    ACTA PHYSICO-CHIMICA SINICA, 2007, 23 (04) : 585 - 589
  • [27] ELECTRON-TRANSFER ON AN ELECTRODE OF GLUCOSE-OXIDASE IMMOBILIZED IN POLYANILINE
    LU, SY
    LI, CF
    ZHANG, DD
    ZHANG, Y
    MO, ZH
    CAI, Q
    ZHU, AR
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 364 (1-2): : 31 - 36
  • [28] BIOELECTROCHEMICAL ACTIVATION AND INHIBITION OF POLYANILINE GLUCOSE-OXIDASE ELECTRODE BY CATIONS
    MU, SL
    KAN, JQ
    ELECTROCHIMICA ACTA, 1995, 40 (02) : 241 - 246
  • [29] Polyaniline-graphite on cellulose substrate: a flexible, low-cost, use-and-throw sensor for glucose concentration detection
    Das, Dipankar
    Das, Jayanta
    Debnath, Ajit
    Chakraborty, Santanu
    Saha, Biswajit
    CELLULOSE, 2023, 30 (10) : 6423 - 6433
  • [30] Electrochemical Sensing of Glucose at a Platinum Electrode with a Chitin/Glucose Oxidase Film
    Kazuharu Sugawara
    Hiroshi Fukushi
    Suwaru Hoshi
    Kunihiko Akatsuka
    Analytical Sciences, 2000, 16 : 1139 - 1143