Dosimetric parameters of palladium-103 brachytherapy source with Monte Carlo simulation

被引:0
|
作者
WANG JianHua
机构
基金
中国国家自然科学基金;
关键词
brachytherapy; Monte Carlo; model ADVANTAGETM; palladium-103; dosimetric parameters; dose rate constants;
D O I
暂无
中图分类号
R730.5 [肿瘤治疗学];
学科分类号
100214 ;
摘要
Before clinical application of a new source, the dosimetric parameters of the source should be accu- rately determined. This work is dedicated to the Monte Carlo method to calculate dosimetric parameters as recommended by the American Association of Physicists in Medicine (AAPM) TG-43 guidelines for model ADVANTAGETM palladium-103 source and, through comparison with data from another published report for the same source, presents a suggested dataset for clinical applications. From these calcula- tions, tables are presented for the radial dose function and the anisotropy function of palladium-103 brachytherapy source. The dose rate constants are found to be 0.671 (cGyh-1U-1) in liquid water and 0.673 (cGyh-1U-1) in Solid WaterTM. And the anisotropy constants in liquid water and Solid WaterTM are found to be 0.864 and 0.865 respectively. Comparison with the previous study shows that our results of dosimetric parameters are in good agreement with those measured and calculated by Meigooni et al. (2006) both in Water and Solid WaterTM.
引用
收藏
页码:1304 / 1309
页数:6
相关论文
共 50 条
  • [1] Dosimetric parameters of palladium-103 brachytherapy source with Monte Carlo simulation
    Wang JianHua
    Liu Wei
    Xu XunJiang
    Gu JiaHui
    Cai Jun
    Hua ZhengDong
    Xu JiaQiang
    [J]. CHINESE SCIENCE BULLETIN, 2008, 53 (09): : 1304 - 1309
  • [2] Dose Analysis at Palladium-103 Brachytherapy of Prostate Cancer Using Monte Carlo Method
    Setiawati, Evi
    Oktajianto, Hammam
    Umiyati, Ngurah Ayu Ketut
    [J]. ADVANCED SCIENCE LETTERS, 2017, 23 (07) : 6589 - 6592
  • [3] Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-103Pd brachytherapy source
    Sadeghi, Mahdi
    Raisali, Gholamreza
    Hosseini, S. Hamed
    Shavar, Arzhang
    [J]. MEDICAL PHYSICS, 2008, 35 (04) : 1288 - 1294
  • [4] Dosimetric parameters of the new design 103Pd brachytherapy source based on Monte Carlo study
    Saidi, Pooneh
    Sadeghi, Mahdi
    Shirazi, Alireza
    Tenreiro, Claudio
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (01): : 13 - 18
  • [5] Dosimetric comparison of cesium-131 and palladium-103 for permanent prostate brachytherapy
    Musmacher, J.
    Byrnes, R.
    Satchwill, K.
    Rumpf, L.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2440 - 2440
  • [6] Experimental measurements and Monte Carlo calculations of dosimetric parameters of the IRA1-103Pd brachytherapy source
    Sadeghi, Mahdi
    Hosseini, S. Hamed
    Raisali, Gholamreza
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (10) : 1431 - 1437
  • [7] Dosimetric comparison of Cesium-131 and Palladium-103 for permanent prostate brachytherapy
    Musmacher, J. S.
    Bymes, R. T.
    Ghaly, M.
    Satchwill, K.
    Rumpf, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S730 - S731
  • [8] Palladium-103 brachytherapy for prostate carcinoma
    Blasko, JC
    Grimm, PD
    Sylvester, JE
    Badiozamani, KR
    Hoak, D
    Cavanagh, W
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (04): : 839 - 850
  • [9] Monte Carlo dosimetric characterization of the IsoAid ADVANTAGE 103Pd brachytherapy source
    Sowards, Keith T.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 18 - 25
  • [10] Monte Carlo simulation of HDR Brachytherapy dosimetric parameters in different mediums
    Shukor, Nor Shazleen Ab
    Musarudin, Marianie
    Abdullah, Reduan
    Aziz, Mohd Zahri Abd
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 200