Monte Carlo simulation of HDR Brachytherapy dosimetric parameters in different mediums

被引:0
|
作者
Shukor, Nor Shazleen Ab [1 ]
Musarudin, Marianie [1 ]
Abdullah, Reduan [2 ]
Aziz, Mohd Zahri Abd [3 ]
机构
[1] Univ Sains Malaysia, Sch Hlth Sci, Hlth Campus, Kubang Kerian 16150, Kelantan, Malaysia
[2] Hosp Univ Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia
[3] Univ Sains Malaysia, Adv Med & Dent Inst, George Town, Kepala Batas, Malaysia
关键词
MCNP5; Brachytherapy; Radial dose; Anisotropy; TREATMENT PLANNING SYSTEM; DOSE CALCULATION; HIP PROSTHESES; AAPM; ACCURACY;
D O I
10.1016/j.radphyschem.2022.110227
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aims to investigate the influence of different materials on the dosimetric parameters of the 192Ir microSelectron HDR source using the MCNP5 code. As a preliminary, the MCNP5 code was initially verified with the published data, and the relative differences were calculated. Homogeneous phantoms, filled with lung, bone, air, and steels materials for a common hip prosthesis such as titanium alloy (Ti), stainless steel, and cobalt -chromium-molybdenum (Co-Cr-Mo) are modeled in this study. Using MCNP5 code, a database for 192Ir HDR Brachytherapy in a standard water phantom and other materials as described above was constructed. The data obtained from the simulation were then used for the calculation of the radial dose function, g(r) and anisotropy function F(r,theta). From the finding, g(r) for bone, lung, and air are water equivalent at r < 6 cm. At r> 6 cm, the TPS overestimate from 7.7% to 35.9% for bone and underestimate the lung dose (2.94%-33%) and air (2.81%- 46.4%). For steels, a large relative difference of up to 62.2% is calculated due to the higher density compared to the water. Meanwhile, a greater relative difference for F(r,theta) is observed at the angle parallel to the Nucletron 192Ir microSelectron HDR source. An increase in the density of the medium leads to inconsistencies in the flatness of the F(r,theta). Great attention should be given to the region greater than 6 cm and the presence of any material other than water at the respective distance could lead to significant underestimation or overestimation of the dosimetric parameters.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Dosimetric Accuracy of an HDR Brachytherapy Treatment Planning System for Different Irradiation Lengths with Monte Carlo Simulation
    Acun Bucht, Hediye
    Bozkurt, Ahmet
    Kemikler, Gonul
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (01): : 36 - 44
  • [2] Dosimetric parameters of palladium-103 brachytherapy source with Monte Carlo simulation
    WANG JianHua
    [J]. Science Bulletin, 2008, (09) : 1304 - 1309
  • [3] Dosimetric parameters of palladium-103 brachytherapy source with Monte Carlo simulation
    Wang JianHua
    Liu Wei
    Xu XunJiang
    Gu JiaHui
    Cai Jun
    Hua ZhengDong
    Xu JiaQiang
    [J]. CHINESE SCIENCE BULLETIN, 2008, 53 (09): : 1304 - 1309
  • [4] Evaluation of Dosimetric Parameters of Two Brachytherapy Ophthalmic Sources Using Monte Carlo Simulation
    Ramon, P.
    Quevedo, A.
    Pianoschi, T.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [5] Monte Carlo dosimetry in HDR brachytherapy
    Martínez-Dávalos, A
    [J]. MEDICAL PHYSICS, 2000, 538 : 128 - 133
  • [6] Study of the IsoAid ADVANTAGE™ 125I brachytherapy source dosimetric parameters using Monte Carlo simulation
    Sadeghi, Mahdi
    Hosseini, S. Hamed
    [J]. APPLIED RADIATION AND ISOTOPES, 2010, 68 (01) : 211 - 213
  • [7] Monte Carlo evaluation of kerma in an HDR brachytherapy bunker
    Pérez-Calatayud, J
    Granero, D
    Ballester, F
    Casal, E
    Crispin, V
    Puchades, V
    León, A
    Verdú, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (24): : N389 - N396
  • [8] Benchmark of the PenRed Monte Carlo framework for HDR brachytherapy
    Oliver, S.
    Gimenez-Alventosa, V.
    Berumen, F.
    Gimenez, V.
    Beaulieu, L.
    Ballester, F.
    Vijande, J.
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (04): : 511 - 528
  • [9] Monte Carlo simulation and dosimetry measurements of an experimental approach for in vitro HDR brachytherapy irradiation
    Geraldo, Jony M.
    Andrade, Lidia M.
    Nogueira, Luciana B.
    Grundmann, Cassia T.
    Fonseca, Telma C. F.
    Gomes, Bruno G. S.
    Leite, Miguel T. T.
    Mafra, Arnoldo
    Goncalves, Kennedy B.
    Furtado, Clascidia A.
    Ladeira, Luiz O.
    [J]. APPLIED RADIATION AND ISOTOPES, 2021, 172
  • [10] Dosimetric Impact of TG4(3) Formalism Versus Monte Carlo in HDR Breast Cancer Brachytherapy
    Turgeon, V.
    Bahoric, B.
    Morcos, M.
    Enger, S. Abbasinejad
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E757 - E757