Preservation of Liver Graft Using the Hypothermic Oxygenated Perfusion (HOPE) System: A single-center experience

被引:0
|
作者
Tamayo, Beatriz Villota [1 ,2 ,3 ]
Valero, Arkaitz Perfecto [2 ,3 ]
Ordorica, Patricia Ruiz [2 ,3 ]
Castineira, Alberto Ventoso [2 ,3 ]
Portela, Gerardo Moro [1 ,2 ,3 ]
Gutierrez, Jaime Encinas [1 ,2 ,3 ]
Etxeberria, Ibone Palomares [2 ,3 ]
Calvo, Mikel Prieto [2 ,3 ]
Herrero, Sara Mambrilla [2 ,3 ]
Vicente, Teresa Pascual [1 ,2 ]
Ibarreche, Eunate Muga [2 ,4 ]
Labiano, Maria Senosiain [2 ]
Mateo, Mikel Gastaca [2 ,3 ]
机构
[1] Cruces Univ Hosp, Gen Surg Dept, Bilbao, Spain
[2] BioBizkaia Res Hlth Inst, Baracaldo, Bizkaia, Spain
[3] Cruces Univ Hosp, Hepatobiliary Surg & Liver Transplantat Unit, Bilbao, Spain
[4] Cruces Univ Hosp, Hepatol & Liver Transplantat Unit, Bilbao, Spain
关键词
MACHINE PERFUSION; TRANSPLANTATION;
D O I
10.1016/j.transproceed.2024.12.006
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Introduction. The hypothermic oxygenated perfusion (HOPE) system has been developed to improve the quality of previously considered suboptimal liver grafts, reduce complications, and increase the number of available donors. The aim of this study is to evaluate the results since its implementation in the liver transplant (LT) program at our center. Materials and Methods. We conducted a retrospective descriptive analysis of all LTs with HOPE from August 2022 to November 2023 with a minimum follow-up of 3 months. The indication criteria included: donor >75 years, macrovesicular steatosis (>30%) confirmed by biopsy, donor >70 years with additional risk factors (macroscopic steatosis or grossly suboptimal liver), anticipated cold ischemia time >6 hours, and donation after circulatory death with suboptimal graft or laboratory results. Results. Of the 96 LTs performed during this period, HOPE was used in 12 cases (12.5%). Two patients (16.7%) experienced postreperfusion syndrome, and one (8.3%) early allograft dysfunction was noted. Four patients (33.3%) had major surgical complications (Clavien-Dindo >= III). The median peak of ALT during the first 48 hours was 438.5 U/L (range 128-2475). There were two biliary complications (16.7%), one venous complication (8.3%), and two arterial complications (16.7%). With a median follow-up of 7.8 months, both patient survival and graft survival were 100%. Conclusion. In our experience, the use of HOPE seems to reduce ischemic damage and shows good short- and medium-term results.
引用
收藏
页码:55 / 58
页数:4
相关论文
共 50 条
  • [41] A Novel Oxygenated Machine Perfusion System for Preservation of the Liver
    Dirkes, Marcel C.
    Post, Ivo C. J. H.
    Heger, Michal
    van Gulik, Thomas M.
    ARTIFICIAL ORGANS, 2013, 37 (08) : 719 - 724
  • [42] EX-VIVO LIVER SPLITTING DURING HYPOTHERMIC OXYGENATED PERFUSION : A NOVEL PROCEDURE TO OPTIMIZE GRAFT PRESERVATION IN SPLIT LIVER TRANSPLANTATION
    Rossignol, Guillaume
    Muller, Xavier
    Lesurtel, Mickael
    Dubois, Remi
    Mohkam, Kayvan
    Mabrut, Jean Yves
    TRANSPLANT INTERNATIONAL, 2021, 34 : 312 - 313
  • [43] EXTENDED DONOR HEART PRESERVATION USING A SINGLE-USE DEVICE BASED ON OXYGENATED HYPOTHERMIC PERFUSION
    Anderson, Lisa
    Salvail, Dan
    Dupre, Emilie
    D'alessandro, David
    TRANSPLANT INTERNATIONAL, 2015, 28 : 177 - 177
  • [44] Reply: Portable hypothermic oxygenated machine perfusion for organ preservation in liver transplantation (PILOT)
    Lunsford, Keri E.
    Panayotova, Guergana G.
    Guarrera, James V.
    HEPATOLOGY, 2024, 79 (06) : E167 - E168
  • [45] Real-Time Biomarkers of Liver Graft Quality in Hypothermic Oxygenated Machine Perfusion
    Zhylko, Andriy
    Morawski, Marcin
    Rykowski, Pawel
    Krasnodebski, Maciej
    Wyporski, Anya
    Borkowski, Jan
    Zhylko, Dmytro
    Kobryn, Konrad
    Stankiewicz, Rafal
    Stypulkowski, Jan
    Holowko, Waclaw
    Patkowski, Waldemar
    Wroblewski, Tadeusz
    Szczepankiewicz, Benedykt
    Gornicka, Barbara
    Mielczarek-Puta, Magdalena
    Struga, Marta
    Krawczyk, Marek
    Grat, Michal
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (02)
  • [46] HYPOTHERMIC OXYGENATED PERFUSION (HOPE) PREVENTS BILIARY INJURY AFTER TRANSPLANTATION OF DCD LIVER GRAFTS
    Schlegel, Andrea
    Graf, Rolf
    Clavien, Pierre-Alain
    Dutkowski, Philipp
    TRANSPLANT INTERNATIONAL, 2013, 26 : 65 - 65
  • [47] IMPACT OF HYPOTHERMIC OXYGENATED MACHINE PERFUSION (HOPE) ON IMMUNE RESPONSE IN A RODENT MODEL OF LIVER TRANSPLANTATION
    Schlegel, A.
    Kron, P.
    Graf, R.
    Clavien, P. -A.
    Dutkowski, P.
    JOURNAL OF HEPATOLOGY, 2014, 60 (01) : S530 - S531
  • [48] Eleven hours of hypothermic oxygenated machine perfusion (HOPE) for complex liver retransplantation: A case report
    Boteon, Amanda P. C. S.
    Lima, Marisa R. D.
    Guardia, Bianca Della
    Carvalho, Mauricio F.
    Schlegel, Andrea
    Boteon, Yuri L.
    ARTIFICIAL ORGANS, 2023, 47 (08) : 1413 - 1415
  • [49] A single-center experience of retransplantation for liver transplant recipients with a failing graft
    Chen, G. -H.
    Fu, B. -S.
    Cai, C. -J.
    Lu, M. -Q.
    Yang, Y.
    Yi, S. -H.
    Xu, C.
    Li, H.
    Wang, G. -S.
    Zhang, T.
    TRANSPLANTATION PROCEEDINGS, 2008, 40 (05) : 1485 - 1487
  • [50] 5-year Experience in Human Extended DCD Liver Transplantation Treated by Hypothermic Oxygenated Perfusion (HOPE) before Implantation
    Schlegel, A.
    Muller, X.
    Perera, T.
    Clavien, P. -A
    Isaac, J.
    Muiesan, P.
    Dutkowski, P.
    TRANSPLANTATION, 2017, 101 (05) : 14 - 14