共 50 条
Preservation of Liver Graft Using the Hypothermic Oxygenated Perfusion (HOPE) System: A single-center experience
被引:0
|作者:
Tamayo, Beatriz Villota
[1
,2
,3
]
Valero, Arkaitz Perfecto
[2
,3
]
Ordorica, Patricia Ruiz
[2
,3
]
Castineira, Alberto Ventoso
[2
,3
]
Portela, Gerardo Moro
[1
,2
,3
]
Gutierrez, Jaime Encinas
[1
,2
,3
]
Etxeberria, Ibone Palomares
[2
,3
]
Calvo, Mikel Prieto
[2
,3
]
Herrero, Sara Mambrilla
[2
,3
]
Vicente, Teresa Pascual
[1
,2
]
Ibarreche, Eunate Muga
[2
,4
]
Labiano, Maria Senosiain
[2
]
Mateo, Mikel Gastaca
[2
,3
]
机构:
[1] Cruces Univ Hosp, Gen Surg Dept, Bilbao, Spain
[2] BioBizkaia Res Hlth Inst, Baracaldo, Bizkaia, Spain
[3] Cruces Univ Hosp, Hepatobiliary Surg & Liver Transplantat Unit, Bilbao, Spain
[4] Cruces Univ Hosp, Hepatol & Liver Transplantat Unit, Bilbao, Spain
关键词:
MACHINE PERFUSION;
TRANSPLANTATION;
D O I:
10.1016/j.transproceed.2024.12.006
中图分类号:
R392 [医学免疫学];
Q939.91 [免疫学];
学科分类号:
100102 ;
摘要:
Introduction. The hypothermic oxygenated perfusion (HOPE) system has been developed to improve the quality of previously considered suboptimal liver grafts, reduce complications, and increase the number of available donors. The aim of this study is to evaluate the results since its implementation in the liver transplant (LT) program at our center. Materials and Methods. We conducted a retrospective descriptive analysis of all LTs with HOPE from August 2022 to November 2023 with a minimum follow-up of 3 months. The indication criteria included: donor >75 years, macrovesicular steatosis (>30%) confirmed by biopsy, donor >70 years with additional risk factors (macroscopic steatosis or grossly suboptimal liver), anticipated cold ischemia time >6 hours, and donation after circulatory death with suboptimal graft or laboratory results. Results. Of the 96 LTs performed during this period, HOPE was used in 12 cases (12.5%). Two patients (16.7%) experienced postreperfusion syndrome, and one (8.3%) early allograft dysfunction was noted. Four patients (33.3%) had major surgical complications (Clavien-Dindo >= III). The median peak of ALT during the first 48 hours was 438.5 U/L (range 128-2475). There were two biliary complications (16.7%), one venous complication (8.3%), and two arterial complications (16.7%). With a median follow-up of 7.8 months, both patient survival and graft survival were 100%. Conclusion. In our experience, the use of HOPE seems to reduce ischemic damage and shows good short- and medium-term results.
引用
收藏
页码:55 / 58
页数:4
相关论文