Real-Time Biomarkers of Liver Graft Quality in Hypothermic Oxygenated Machine Perfusion

被引:0
|
作者
Zhylko, Andriy [1 ,2 ]
Morawski, Marcin [1 ,2 ]
Rykowski, Pawel [1 ,2 ]
Krasnodebski, Maciej [1 ]
Wyporski, Anya [1 ]
Borkowski, Jan [1 ]
Zhylko, Dmytro [3 ]
Kobryn, Konrad [1 ]
Stankiewicz, Rafal [1 ]
Stypulkowski, Jan [1 ,2 ]
Holowko, Waclaw [1 ]
Patkowski, Waldemar [1 ]
Wroblewski, Tadeusz [1 ]
Szczepankiewicz, Benedykt [4 ]
Gornicka, Barbara [4 ]
Mielczarek-Puta, Magdalena [5 ]
Struga, Marta [5 ]
Krawczyk, Marek [1 ]
Grat, Michal [1 ,2 ]
机构
[1] Med Univ Warsaw, Dept Gen Transplant & Liver Surg, Banacha 1a, PL-02097 Warsaw, Poland
[2] Med Univ Warsaw, Doctoral Sch, PL-02091 Warsaw, Poland
[3] New York Univ Abu Dhabi, Comp Engn Div, POB 129188, Abu Dhabi, U Arab Emirates
[4] Med Univ Warsaw, Dept Pathol, PL-02004 Warsaw, Poland
[5] Med Univ Warsaw, Dept Biochem, PL-02097 Warsaw, Poland
关键词
allograft function; biomarkers; liver transplantation; machine perfusion; EARLY ALLOGRAFT DYSFUNCTION; STATIC COLD-STORAGE; TRANSPLANTATION; DEATH; PRESERVATION; DONATION; REPERFUSION; CRITERIA; INJURY; METABOLOMICS;
D O I
10.3390/jcm14020471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Hypothermic oxygenated machine perfusion has emerged as a strategy to alleviate ischemic-reperfusion injury in liver grafts. Nevertheless, there is limited data on the effectiveness of hypothermic liver perfusion in evaluating organ quality. This study aimed to introduce a readily accessible real-time predictive biomarker measured in machine perfusate for post-transplant liver graft function. Methods: The study evaluated perfusate analytes over a 90-day postoperative period in 26 patients randomly assigned to receive a liver graft following dual hypothermic machine perfusion in a prospective randomized controlled trial. Machine perfusion was consistently conducted end-ischemically for at least 120 min, with real-time perfusate assessment at 30-min intervals. Graft functionality was assessed using established metrics, including Early Allograft Dysfunction (EAD). Results: Perfusate lactate concentration after 120 min of machine perfusion demonstrated significant predictive value for EAD (AUC ROC: 0.841, p = 0.009). Additionally, it correlated with post-transplant peak transaminase levels and extended hospital stays. Subgroup analysis revealed significantly higher lactate accumulation in livers with post-transplant EAD. Conclusions: Liver graft quality can be effectively assessed during hypothermic machine perfusion using simple perfusate lactate measurements. The reliability and accessibility of this evaluation support its potential integration into diverse transplant centers.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Novel Real-time Prediction of Liver Graft Function During Hypothermic Oxygenated Machine Perfusion Before Liver Transplantation
    Muller, Xavier
    Schlegel, Andrea
    Kron, Philipp
    Eshmuminov, Dilmurodjon
    Wuerdinger, Michael
    Meierhofer, David
    Clavien, Pierre-Alain
    Dutkowski, Philipp
    ANNALS OF SURGERY, 2019, 270 (05) : 783 - 790
  • [2] Comment on "Novel Real-time Prediction of Liver Graft Function During Hypothermic Oxygenated Machine Perfusion Before Liver Transplantation''
    Patrono, Damiano
    Sofia, Silvia
    Caropreso, Paola
    Catalano, Giorgia
    Rizza, Giorgia
    Mazza, Elena
    Mengozzi, Giulio
    Romagnoli, Renato
    ANNALS OF SURGERY, 2021, 274 (06) : E686 - E688
  • [3] Novel real time prediction of liver graft function during hypothermic oxygenated machine perfusion prior to liver transplantation
    Schlegel, A.
    Mueller, X.
    Kron, P.
    Eshmuminov, D.
    Wuerdinger, M.
    Meierhofer, D.
    Clavien, P. -A
    Dutkowski, P.
    TRANSPLANTATION, 2019, 103 (08) : 50 - 51
  • [4] Novel real time prediction of liver graft function during hypothermic oxygenated machine perfusion prior to liver transplantation
    Dutkowski, Philipp
    Muller, Xavier
    Schlegel, Andrea
    Kron, Philipp
    Eshmuminov, Dilmurodjon
    Wuerdinger, Michael
    Meierhofer, David
    Clavien, Pierre-Alain
    JOURNAL OF HEPATOLOGY, 2019, 70 (01) : E104 - E105
  • [5] Hypothermic oxygenated perfusion for a steatotic liver graft
    Quirino Lai
    Franco Ruberto
    Fabio Melandro
    Zoe Larghi Laureiro
    Massimo Rossi
    Gianluca Mennini
    Hepatobiliary & Pancreatic Diseases International, 2020, 19 (01) : 88 - 90
  • [6] Hypothermic oxygenated perfusion for a steatotic liver graft
    Lai, Quirino
    Ruberto, Franco
    Melandro, Fabio
    Laureiro, Zoe Larghi
    Rossi, Massimo
    Mennini, Gianluca
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2020, 19 (01) : 88 - 90
  • [7] Hypothermic machine perfusion for liver graft preservation
    Amin, Arpit
    Panayotova, Guergana
    Guarrera, James V.
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2022, 27 (02) : 98 - 105
  • [8] Effluent Molecular Analysis Guides Liver Graft Allocation to Clinical Hypothermic Oxygenated Machine Perfusion
    Lonati, Caterina
    Schlegel, Andrea
    Battistin, Michele
    Merighi, Riccardo
    Carbonaro, Margherita
    Dongiovanni, Paola
    Leonardi, Patrizia
    Zanella, Alberto
    Dondossola, Daniele
    BIOMEDICINES, 2021, 9 (10)
  • [9] Hypothermic Oxygenated Machine Perfusion for Liver Transplantation: An Initial Experience
    Patrono, Damiano
    Lavezzo, Bruna
    Molinaro, Luca
    Rizza, Giorgia
    Catalano, Giorgia
    Gonella, Federica
    Salizzoni, Mauro
    Romagnoli, Renato
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2018, 16 (02) : 172 - 176
  • [10] The Airdrive: a disposable hypothermic oxygenated machine perfusion system for the liver
    Dirkes, M. C.
    Post, I. C.
    van Gulik, T. M.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : S61 - S61