Real-Time Biomarkers of Liver Graft Quality in Hypothermic Oxygenated Machine Perfusion

被引:0
|
作者
Zhylko, Andriy [1 ,2 ]
Morawski, Marcin [1 ,2 ]
Rykowski, Pawel [1 ,2 ]
Krasnodebski, Maciej [1 ]
Wyporski, Anya [1 ]
Borkowski, Jan [1 ]
Zhylko, Dmytro [3 ]
Kobryn, Konrad [1 ]
Stankiewicz, Rafal [1 ]
Stypulkowski, Jan [1 ,2 ]
Holowko, Waclaw [1 ]
Patkowski, Waldemar [1 ]
Wroblewski, Tadeusz [1 ]
Szczepankiewicz, Benedykt [4 ]
Gornicka, Barbara [4 ]
Mielczarek-Puta, Magdalena [5 ]
Struga, Marta [5 ]
Krawczyk, Marek [1 ]
Grat, Michal [1 ,2 ]
机构
[1] Med Univ Warsaw, Dept Gen Transplant & Liver Surg, Banacha 1a, PL-02097 Warsaw, Poland
[2] Med Univ Warsaw, Doctoral Sch, PL-02091 Warsaw, Poland
[3] New York Univ Abu Dhabi, Comp Engn Div, POB 129188, Abu Dhabi, U Arab Emirates
[4] Med Univ Warsaw, Dept Pathol, PL-02004 Warsaw, Poland
[5] Med Univ Warsaw, Dept Biochem, PL-02097 Warsaw, Poland
关键词
allograft function; biomarkers; liver transplantation; machine perfusion; EARLY ALLOGRAFT DYSFUNCTION; STATIC COLD-STORAGE; TRANSPLANTATION; DEATH; PRESERVATION; DONATION; REPERFUSION; CRITERIA; INJURY; METABOLOMICS;
D O I
10.3390/jcm14020471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Hypothermic oxygenated machine perfusion has emerged as a strategy to alleviate ischemic-reperfusion injury in liver grafts. Nevertheless, there is limited data on the effectiveness of hypothermic liver perfusion in evaluating organ quality. This study aimed to introduce a readily accessible real-time predictive biomarker measured in machine perfusate for post-transplant liver graft function. Methods: The study evaluated perfusate analytes over a 90-day postoperative period in 26 patients randomly assigned to receive a liver graft following dual hypothermic machine perfusion in a prospective randomized controlled trial. Machine perfusion was consistently conducted end-ischemically for at least 120 min, with real-time perfusate assessment at 30-min intervals. Graft functionality was assessed using established metrics, including Early Allograft Dysfunction (EAD). Results: Perfusate lactate concentration after 120 min of machine perfusion demonstrated significant predictive value for EAD (AUC ROC: 0.841, p = 0.009). Additionally, it correlated with post-transplant peak transaminase levels and extended hospital stays. Subgroup analysis revealed significantly higher lactate accumulation in livers with post-transplant EAD. Conclusions: Liver graft quality can be effectively assessed during hypothermic machine perfusion using simple perfusate lactate measurements. The reliability and accessibility of this evaluation support its potential integration into diverse transplant centers.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Comparison between oxygenated and non-oxygenated hypothermic Machine Perfusion
    Manekeller, Steffen
    ZENTRALBLATT FUR CHIRURGIE, 2021, 146 (03): : 226 - 226
  • [32] Hypothermic Oxygenated Machine Perfusion of the Human Donor Pancreas
    Leemkuil, Marjolein
    Lier, Grietje
    Engelse, Marten A.
    Ploeg, Rutger J.
    de Koning, Eelco J. P.
    t'Hart, Nils A.
    Krikke, Christina
    Leuvenink, Henri G. D.
    TRANSPLANTATION DIRECT, 2018, 4 (10):
  • [33] Ex Situ Dual Hypothermic Oxygenated Machine Perfusion for Human Split Liver Transplantation
    Thorne, Adam M.
    Lantinga, Veerle
    Bodewes, Silke
    de Kleine, Ruben H. J.
    Nijkamp, Maarten W.
    Sprakel, Joost
    Hartog, Hermien
    Polak, Wojciech G.
    Porte, Robert J.
    de Meijer, Vincent E.
    TRANSPLANTATION DIRECT, 2021, 7 (03): : E666
  • [34] Graft protection of the liver by hypothermic machine perfusion involves recovery of graft regeneration in rats
    Jia, Jun-Jun
    Xie, Hai-Yang
    Li, Jian-Hui
    He, Yong
    Jiang, Li
    He, Ning
    Zhou, Lin
    Wang, Weilin
    Zheng, Shu-Sen
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (01) : 427 - 437
  • [35] Hypothermic Oxygenated Machine Perfusion of Liver Grafts from Brain-Dead Donors
    Patrono, Damiano
    Surra, Astrid
    Catalano, Giorgia
    Rizza, Giorgia
    Berchialla, Paola
    Martini, Silvia
    Tandoi, Francesco
    Lupo, Francesco
    Mirabella, Stefano
    Stratta, Chiara
    Salizzoni, Mauro
    Romagnoli, Renato
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [36] Impact of Hypothermic Oxygenated Machine Perfusion on Hepatocellular Carcinoma Recurrence after Liver Transplantation
    Rigo, Federica
    De Stefano, Nicola
    Patrono, Damiano
    De Donato, Victor
    Campi, Ludovico
    Turturica, Diana
    Doria, Teresa
    Sciannameo, Veronica
    Berchialla, Paola
    Tandoi, Francesco
    Romagnoli, Renato
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [37] Hypothermic Oxygenated Machine Perfusion of Liver Grafts from Brain-Dead Donors
    Damiano Patrono
    Astrid Surra
    Giorgia Catalano
    Giorgia Rizza
    Paola Berchialla
    Silvia Martini
    Francesco Tandoi
    Francesco Lupo
    Stefano Mirabella
    Chiara Stratta
    Mauro Salizzoni
    Renato Romagnoli
    Scientific Reports, 9
  • [38] Dual hypothermic oxygenated machine perfusion in liver transplants donated after circulatory death
    van Rijn, R.
    Karimian, N.
    Matton, A. P. M.
    Burlage, L. C.
    Westerkamp, A. C.
    van den Berg, A. P.
    de Kleine, R. H. J.
    de Boer, M. T.
    Lisman, T.
    Porte, R. J.
    BRITISH JOURNAL OF SURGERY, 2017, 104 (07) : 907 - 917
  • [39] Clinical assessment of liver metabolism during hypothermic oxygenated machine perfusion using microdialysis
    Patrono, Damiano
    Roggio, Dorotea
    Mazzeo, Anna Teresa
    Catalano, Giorgia
    Mazza, Elena
    Rizza, Giorgia
    Gambella, Alessandro
    Rigo, Federica
    Leone, Nicola
    Elia, Vincenzo
    Dondossola, Daniele
    Lonati, Caterina
    Fanelli, Vito
    Romagnoli, Renato
    ARTIFICIAL ORGANS, 2022, 46 (02) : 281 - 295
  • [40] Reply: Portable hypothermic oxygenated machine perfusion for organ preservation in liver transplantation (PILOT)
    Lunsford, Keri E.
    Panayotova, Guergana G.
    Guarrera, James V.
    HEPATOLOGY, 2024, 79 (06) : E167 - E168