Preservation of Liver Graft Using the Hypothermic Oxygenated Perfusion (HOPE) System: A single-center experience

被引:0
|
作者
Tamayo, Beatriz Villota [1 ,2 ,3 ]
Valero, Arkaitz Perfecto [2 ,3 ]
Ordorica, Patricia Ruiz [2 ,3 ]
Castineira, Alberto Ventoso [2 ,3 ]
Portela, Gerardo Moro [1 ,2 ,3 ]
Gutierrez, Jaime Encinas [1 ,2 ,3 ]
Etxeberria, Ibone Palomares [2 ,3 ]
Calvo, Mikel Prieto [2 ,3 ]
Herrero, Sara Mambrilla [2 ,3 ]
Vicente, Teresa Pascual [1 ,2 ]
Ibarreche, Eunate Muga [2 ,4 ]
Labiano, Maria Senosiain [2 ]
Mateo, Mikel Gastaca [2 ,3 ]
机构
[1] Cruces Univ Hosp, Gen Surg Dept, Bilbao, Spain
[2] BioBizkaia Res Hlth Inst, Baracaldo, Bizkaia, Spain
[3] Cruces Univ Hosp, Hepatobiliary Surg & Liver Transplantat Unit, Bilbao, Spain
[4] Cruces Univ Hosp, Hepatol & Liver Transplantat Unit, Bilbao, Spain
关键词
MACHINE PERFUSION; TRANSPLANTATION;
D O I
10.1016/j.transproceed.2024.12.006
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Introduction. The hypothermic oxygenated perfusion (HOPE) system has been developed to improve the quality of previously considered suboptimal liver grafts, reduce complications, and increase the number of available donors. The aim of this study is to evaluate the results since its implementation in the liver transplant (LT) program at our center. Materials and Methods. We conducted a retrospective descriptive analysis of all LTs with HOPE from August 2022 to November 2023 with a minimum follow-up of 3 months. The indication criteria included: donor >75 years, macrovesicular steatosis (>30%) confirmed by biopsy, donor >70 years with additional risk factors (macroscopic steatosis or grossly suboptimal liver), anticipated cold ischemia time >6 hours, and donation after circulatory death with suboptimal graft or laboratory results. Results. Of the 96 LTs performed during this period, HOPE was used in 12 cases (12.5%). Two patients (16.7%) experienced postreperfusion syndrome, and one (8.3%) early allograft dysfunction was noted. Four patients (33.3%) had major surgical complications (Clavien-Dindo >= III). The median peak of ALT during the first 48 hours was 438.5 U/L (range 128-2475). There were two biliary complications (16.7%), one venous complication (8.3%), and two arterial complications (16.7%). With a median follow-up of 7.8 months, both patient survival and graft survival were 100%. Conclusion. In our experience, the use of HOPE seems to reduce ischemic damage and shows good short- and medium-term results.
引用
收藏
页码:55 / 58
页数:4
相关论文
共 50 条
  • [21] Single center experience with ex-situ hypothermic oxygenated machine perfusion prior to liver transplantation: an interim analysis
    Sanders, J.
    Callegari, M.
    Dietch, Z.
    Nadig, S.
    Caicedo, J. C.
    Borja-Cacho, D.
    LIVER TRANSPLANTATION, 2024, 30 : 267 - 268
  • [22] CLINICAL EXPERIENCE OF HYPOTHERMIC OXYGENATED LIVER PERFUSION WITH STANDARD UW
    Figueiredo, R. S.
    Sewpaul, A.
    Bates, L.
    Ibrahim, I.
    Thompson, E.
    French, J. J.
    Sen, G.
    Talbot, D.
    White, S. A.
    Manas, D. M.
    Wright, M. C.
    Wilson, C. H.
    BRITISH JOURNAL OF SURGERY, 2018, 105 : 10 - 11
  • [23] Hypothermic Oxygenated Machine Perfusion for Liver Transplantation: An Initial Experience
    Patrono, Damiano
    Lavezzo, Bruna
    Molinaro, Luca
    Rizza, Giorgia
    Catalano, Giorgia
    Gonella, Federica
    Salizzoni, Mauro
    Romagnoli, Renato
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2018, 16 (02) : 172 - 176
  • [24] Early experience with oxygenated hypothermic machine perfusion for kidney transplantation at a single center in the United States
    Steggerda, Justin
    Kim, Irene K.
    Todo, Tsuyoshi
    Brennan, Todd V.
    Peng, Alice
    Huang, Edmund
    Shoji, Jun
    Najjar, Reiad
    Voidonikolas, Georgios
    Wisel, Steven A.
    TRANSPLANTATION, 2024, 108 (09) : 104 - 104
  • [25] Rescue of the cold preserved rat liver with hypothermic oxygenated perfusion extracorporeal (HOPE)
    Dutkowski, P
    Graf, R
    Clavien, PA
    BRITISH JOURNAL OF SURGERY, 2005, 92 (07) : 912 - 912
  • [26] Can hypothermic oxygenated perfusion (HOPE) rescue futile DCD liver grafts?
    Muller, X.
    Schlegel, A.
    Wurdinger, M.
    Wendt, M.
    Kron, P.
    Eshmuminov, D.
    Mullhaupt, B.
    Clavien, P. A.
    Dutkowski, P.
    HPB, 2019, 21 (09) : 1156 - 1165
  • [27] LIVER PRESERVATION BY SINGLE PASSAGE HYPOTHERMIC SQUIRT PERFUSION
    CALNE, RY
    BITTERSU.H
    SMITH, DP
    WEBSTER, LM
    HERBERTSON, BM
    DUNN, DC
    GORDON, EM
    REITTER, FH
    ROBSON, AJ
    MACDONALD, AS
    DAVIS, DR
    BMJ-BRITISH MEDICAL JOURNAL, 1972, 4 (5833): : 142 - +
  • [28] Portable hypothermic oxygenated machine perfusion for organ preservation in liver transplantation (PILOT)
    Czigany, Zoltan
    Putri, Aghnia J.
    Michalski, Christoph W.
    Mehrabi, Arianeb
    HEPATOLOGY, 2024, 79 (06) : E165 - E166
  • [29] Superior Donor Heart Preservation Using Hypothermic Oxygenated Perfusion.
    Michel, S.
    La Muraglia, G., II
    Madariaga, M.
    Allan, J.
    Titus, J.
    Selig, M.
    Farkash, E.
    Anderson, L.
    Madsen, J.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 : 370 - 370
  • [30] Superior Donor Heart Preservation Using Hypothermic Oxygenated Perfusion.
    Michel, S.
    La Muraglia, G., II
    Madariaga, M.
    Allan, J.
    Titus, J.
    Selig, M.
    Farkash, E.
    Anderson, L.
    Madsen, J.
    TRANSPLANTATION, 2014, 98 : 370 - 370