摘要
Partial discharge is a fault that occurs at the site of insulation defects within a transformer. Dual instances of partial discharge origination discharging simultaneously embody a more intricate form of discharge, where the interaction between the discharge sources leads to more intricate and unpredictable insulation damage. Conventional piezoelectric transducers are magnetically affixed to the exterior metal tank of transformers. The ultrasonic signals emanating from partial discharge undergo deflection and reverberation upon traversing the windings, insulation paperboards, and the outer shell, resulting in signal attenuation and thus making it difficult to detect such faults. Furthermore, it is challenging to distinguish between simultaneous discharges from dual partial discharge sources and continuous discharges from a single source, often leading to missed detection and repairs of fault points, which increase the maintenance difficulty and cost of power equipment. With the advancement of MEMS (Micro-Electro-Mechanical System) technology, fiber-optic ultrasonic sensors have surfaced as an innovative technique for optically detecting partial discharges. These sensors are distinguished by their minute dimensions, heightened sensitivity, and robust immunity to electromagnetic disturbances. and excellent insulation properties, allowing for internal installation within power equipment for partial discharge monitoring. In this study, we developed an EFPI (Extrinsic Fabry Perot Interferometer) optical fiber ultrasonic sensor that can be installed inside transformers. Based on this sensor array, we also created a partial discharge ultrasonic detection system that estimates the directional information of single and dual partial discharge sources using the received signals from the sensor array. By utilizing the DOA (Direction of Arrival) as a feature recognition parameter, our system can effectively detect both simultaneous discharges from dual partial discharge sources and continuous discharges from a single source within transformer oil tanks, meeting practical application requirements. The detection methodology presented in this paper introduces an original strategy and resolution for pinpointing the types of partial discharges occurring under intricate conditions within power apparatus, effectively distinguishing between discharges from single and dual partial discharge sources.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Dual cladding configuration for the fabrication of fiber-optic sensors.
    Hoyt, AE
    Harrah, LA
    Coons, NC
    Powers, TM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U565 - U565
  • [23] Design and testing of UHF sensors for Partial Discharge detection in transformers
    Lopez-Roldan, J.
    Tang, T.
    Gaskin, M.
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1052 - +
  • [24] A Fiber Optic Ultrasonic Sensor Using Polarization-maintaining Fiber for Partial Discharge Monitoring
    Li, Xuefeng
    Cao, Hexin
    Chang, Zhiming
    Zhang, Xinyu
    Zhao, Weishi
    Shen, Runjie
    SENSORS AND MATERIALS, 2019, 31 (05) : 1407 - 1417
  • [25] Fiber Optic Interferometric GIS Partial Discharge Ultrasonic Sensing Based on Dual Loop Feedback
    Li, Nan
    Chen, Rong
    Zhang, Xiaolong
    Li, Songyuan
    Wang, Xiaopeng
    2024 THE 7TH INTERNATIONAL CONFERENCE ON ENERGY, ELECTRICAL AND POWER ENGINEERING, CEEPE 2024, 2024, : 620 - 623
  • [26] Bearing fault detection and fault size estimation using fiber-optic sensors
    Alian, Hasib
    Konforty, Shlomi
    Ben-Simon, Uri
    Klein, Renata
    Tur, Moshe
    Bortman, Jacob
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 120 : 392 - 407
  • [27] Mandrel-Based Fiber-Optic Sensors for Acoustic Detection of Partial Discharges - a Proof of Concept
    Lima, Sanderson E. U.
    Frazao, Orlando
    Farias, Rubem G.
    Araujo, Francisco M.
    Ferreira, Luis A.
    Santos, Jose L.
    Miranda, Vladimiro
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2526 - 2534
  • [28] Study on Ultrasonic Characteristics and Sensors in Partial Discharge
    Zhao, Guangxing
    Yu, Qing
    MECHATRONICS AND MATERIALS PROCESSING I, PTS 1-3, 2011, 328-330 : 1892 - 1895
  • [29] Experimental study of different approaches to the measurement of mechanical vibrations in transformers with fiber-optic interferometric intrinsic sensors
    García-Souto, JA
    Lamela, H
    17th International Conference on Optical Fibre Sensors, Pts 1 and 2, 2005, 5855 : 655 - 658
  • [30] Research on fiber-optic sensors for methane detection based on Harmonic detection
    Wang, Shutao
    Huang, Liang
    Zhou, Zhishuang
    Zhu, Zhihui
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2010, 7656