Study on the Detection of Single and Dual Partial Discharge Sources in Transformers Using Fiber-Optic Ultrasonic Sensors

被引:0
|
作者
Liu, Feng [1 ]
Shi, Yansheng [1 ]
Zhang, Shuainan [1 ]
Wang, Wei [1 ]
机构
[1] North China Elect Power Univ, Sch Elect & Elect Engn, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
fiber-optic ultrasonic sensors; transformer fault diagnosis; DOA estimation; single and dual PD source detection; DOA ESTIMATION;
D O I
10.3390/photonics11090815
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Partial discharge is a fault that occurs at the site of insulation defects within a transformer. Dual instances of partial discharge origination discharging simultaneously embody a more intricate form of discharge, where the interaction between the discharge sources leads to more intricate and unpredictable insulation damage. Conventional piezoelectric transducers are magnetically affixed to the exterior metal tank of transformers. The ultrasonic signals emanating from partial discharge undergo deflection and reverberation upon traversing the windings, insulation paperboards, and the outer shell, resulting in signal attenuation and thus making it difficult to detect such faults. Furthermore, it is challenging to distinguish between simultaneous discharges from dual partial discharge sources and continuous discharges from a single source, often leading to missed detection and repairs of fault points, which increase the maintenance difficulty and cost of power equipment. With the advancement of MEMS (Micro-Electro-Mechanical System) technology, fiber-optic ultrasonic sensors have surfaced as an innovative technique for optically detecting partial discharges. These sensors are distinguished by their minute dimensions, heightened sensitivity, and robust immunity to electromagnetic disturbances. and excellent insulation properties, allowing for internal installation within power equipment for partial discharge monitoring. In this study, we developed an EFPI (Extrinsic Fabry Perot Interferometer) optical fiber ultrasonic sensor that can be installed inside transformers. Based on this sensor array, we also created a partial discharge ultrasonic detection system that estimates the directional information of single and dual partial discharge sources using the received signals from the sensor array. By utilizing the DOA (Direction of Arrival) as a feature recognition parameter, our system can effectively detect both simultaneous discharges from dual partial discharge sources and continuous discharges from a single source within transformer oil tanks, meeting practical application requirements. The detection methodology presented in this paper introduces an original strategy and resolution for pinpointing the types of partial discharges occurring under intricate conditions within power apparatus, effectively distinguishing between discharges from single and dual partial discharge sources.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Study of Fiber Optic Omnidirectional Sensing for Partial Discharge in Transformers by Combining FBG and FP Cavity
    Wu Ke-jie
    Chen Wei-gen
    Zhang Zhi-xian
    Song Yu-xuan
    Tian Hao-yuan
    Li Meng
    Liu Fan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44 (02) : 510 - 518
  • [32] Optoacoustic imaging using fiber-optic interferometric sensors
    Lamela, Horacio
    Gallego, Daniel
    Oraevsky, Alexander
    OPTICS LETTERS, 2009, 34 (23) : 3695 - 3697
  • [33] Calibration of fiber-optic sensors using universal approximators
    Porada, E.
    Bock, W.J.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1994, 1 : 269 - 272
  • [34] Bridge Monitoring Using Brillouin Fiber-Optic Sensors
    Minardo, Aldo
    Bernini, Romeo
    Amato, Lucio
    Zeni, Luigi
    IEEE SENSORS JOURNAL, 2012, 12 (01) : 145 - 150
  • [35] Floor Pressure Imaging for Fall Detection with Fiber-Optic Sensors
    Feng, Guodong
    Mai, Jiechao
    Ban, Zhen
    Guo, Xuemei
    Wang, Guoli
    IEEE PERVASIVE COMPUTING, 2016, 15 (02) : 40 - 47
  • [36] Partial Discharge Ultrasonic Signal Detection Technology in GIS Based on the Michelson Fiber Optic Interferometer
    Zhou H.
    Ma G.
    Zhang M.
    Wang Y.
    Li C.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (21): : 6452 - 6459
  • [37] Force detection using a fiber-optic cantilever
    Budakian, R
    Putterman, SJ
    APPLIED PHYSICS LETTERS, 2002, 81 (11) : 2100 - 2102
  • [38] Detection of Partial Discharge Sources Using UHF Sensors and Blind Signal Separation
    Boya, Carlos
    Robles, Guillermo
    Parrado-Hernandez, Emilio
    Ruiz-Llata, Marta
    SENSORS, 2017, 17 (11):
  • [39] Partial discharge detection uses optical fiber sensors
    Yu, B
    PHOTONICS SPECTRA, 2003, 37 (09) : 40 - +
  • [40] PARTIAL DISCHARGE DETECTION IN HIGH-VOLTAGE GAS INSULATED SWITCHGEAR USING FIBER OPTIC BASED ACOUSTIC SENSORS
    Zadeh, A. R.
    Heredia, L. C.
    2023 INSUCON - 14TH INTERNATIONAL ELECTRICAL INSULATION CONFERENCE, 2023, : 216 - 220